System Sensor AFD Series
File Preview
Click below to download for free
Click below to download for free
File Data
Name | system-sensor-afd-series-6154928307.pdf |
---|---|
Type | |
Size | 918.91 KB |
Downloads |
Text Preview
S P R I N K L E R S Y S T E M S M O N I T O R I N G Series State Detectors Available Parts Cover wrench Cover tamper switch kit Gasket kit Retard PCB kit Overview state retard assures precise accuracy Switch selections simplify settings two wire design connection to a local bell and or addressable systems with a wide range of pipe including 5 through 40 are equipped with a 4 gasket switches activate the alarm panel and local simultaneously retard assembly cover removed Sensor Accuflow series is a new line of solid state waterflow compatible with a wide range of pipe schedules including 2 schedule 5 detectors can be mounted in a vertical or horizontal position Construction The Accuflow series consists of a rugged enclosure for indoor outdoor use Like all System Sensor waterflow detectors Accuflow models oper across a wide temperature range from 32 to 120 0 to 49 Performance Accuflow detectors incorporate a solid state retard to ensure accurate timing Designed for use within conventional and addressable alarm systems Accuflow detectors include connections for both the panel or module as well as a local bell or notification device Alarm Immunity The solid state circuitry of the Accuflow series provides great timing accuracy over traditional mechanical retard designs This accuracy mini the risk of false alarms created by pressure surges or air trapped within sprinkler system Operation Accuflow detectors are designed to simplify installation Wired traditional waterflow detectors the Accuflow series does not require the installer run an additional third wire Two conduit openings permit easy attachment to the alarm system Specification waterflow detector with a solid state retard shall be an Accuflow Series model number manufactured by System and shall be installed on system piping as designated on the drawing and or as specified herein Detectors shall mount on any pipe span of the appropriate nominal size either on a vertical upflow or horizontal run at least 6 from any fittings which may water direction flow rate or pipe diameter or no closer than 24 from a valve or drain Detectors shall be compatible with sched 5 through 40 for 2 diameter pipe schedule 7 through 40 for 21 2 6 diameter pipe and schedule 10 through 40 for 8 diameter pipe shall have a sensitivity in the range of 4 to 10 gallons per minute and a static pressure rating of 450 psi for 2 8 diameter The detector shall respond to water flow in the specified direction after a preset time delay The delay mechanism shall be a solid unit which is field adjustable via a dipswitch The detector actuation mechanism shall include a polyethylene vane inserted through hole in the pipe and connected by a mechanical linkage to the delay mechanism Outputs shall consist of one SPDT switch Form C con and one SPST switch normally open contact for wiring to an alarm panel or addressable control module and local bell and or noti device Two conduit entrances one knockout type for standard fittings of commonly used electrical conduit shall be provided on detectors A grounding provision shall be provided Unless noted enclosures shall be NEMA 4 listed by Underwriters Laboratories Inc indoor or outdoor use Specifications Pressure Rating PSI Threshold Bandwidth Flow Rate 10 GPM Surge Feet Per Second FPS Pipe water pipe schedule 5 through 40 6 schedule 7 through 40 schedule 10 through 40 Dimensions Installed bolt nut saddle bolt vane Model See Table Information Numbers Pipe Size 2 21 2 3 31 2 4 5 6 8 Entrances openings for 1 2 conduit one open one type Temperature Range 120 0 to 49 Rating 4 suitable for indoor outdoor use Tamper Switch part no 546 9000 Weight 4.1 lbs 1.8 kg 4.2 lbs 1.9 kg 4.4 lbs 2.0 kg 4.6 lbs 2.1 kg 5.1 lbs 2.3 kg 6.2 lbs 2.8 kg 6.7 lbs 3.0 kg 7.4 lbs 3.4 kg Use Sprinkler NFPA 13 or Two Family Dwelling NFPA 13D Occupancies up to stories NFPA 13R Fire Alarm Code NFPA 72 Settings 90 seconds in increments of 15 seconds years Ratings SPDT Form C SPST normally open A 125 VAC A 30 VDC Range 35 V DC FWR 132 VAC Draw microamps 12 24 VDC or FWR microamps 120 VAC Accuflow and Accuflow Low Flow detectors receive power and operate on a two wire zone of a fire alarm control panel When compatibility of these devices the operating voltage of the control panel must between 8.5 and 35 volts In the standby mode Accuflow and Accuflow Low Flow detector as a shot across the initiating zone For two conventional fire alarm control panels not than 5 waterflow detectors may be connected a single initiating zone The maximum retard time of the waterflow detector plus the initi zone shall not exceed 90 seconds two wire addressable control panels the of waterflow detectors connected to the signaling line circuit shall be limited by the current capacity Number Description Cover tamper switch kit Tamper proof wrench for cover Gasket kit Retard PCB kit Sensor Sales and Service Sensor Headquarters Ohio Avenue Charles IL 60174 800 SENSOR2 630 377 6495 On Demand x3 www systemsensor com Sensor in Canada 905.812.0767 905.812.0771 Sensor in Europe 44.1403.276500 44.1403.276501 Sensor in China 86.29.524.6253 86.29.524.6259 Sensor in the Far East 852.21919003 852.27366580 Sensor in India 91.11.558.2119 91.11.567.6815 Sensor in Singapore 65.273.2230 65.273.2610 Sensor in Australia 613.54.281.142 613.54.281.172 2003 System Sensor The company reserves the right to change product specifications without notice A05 0277 002