System Sensor AMCF CO EngSpec

File Preview
File Preview
Click below to download for free

File Data

Name system-sensor-amcf-co-engspec-5792603184.pdf
Type PDF
Size 621.80 KB
Downloads

Text Preview

Product Multi Criteria Fire CO Detector and Engineering Specifications multi criteria fire CO detector shall be an addressable advanced multi criteria smoke with a separate signal for carbon monoxide CO detection per UL 2075 standards detector shall be comprised of four sensing elements including a photoelectric light particulate sensor an electrochemical CO sensor a daylight filtered infrared IR and solid state thermal sensor s rated at 135 57.2 The device shall be able to distinct smoke and heat alarms advanced multi criteria detection device shall include the ability to combine the signal of the signal with other sensing elements in order to react quickly in the event of a fire It shall also include the inherent ability to distinguish between a fire condition and a alarm condition The detector shall be capable of selecting the appropriate sensitivity based on the environment type office manufacturing kitchen etc in which it is installed then have the ability to automatically change the setting as the environment changes CO detector component shall be capable of a functional gas test using a canned test agent test the functionality of the CO sensing cell detector shall be capable of automatically adjusting its sensitivity by means of drift and smoothing algorithms The device shall provide unique signals to indicate 20 percent of the drift range is remaining when 100 percent of drift range is used and there is a chamber fault to show the unit requires maintenance detector shall indicate CO trouble conditions including six months of sensor life remaining sensor life has expired The detector shall indicate a combined signal for any of the following chamber trouble thermistor trouble CO self test failure IR self test failure and freeze detector shall provide address setting means on the detector head using rotary switches of the possibility of installation error systems that use binary jumpers or DIP switches to the detector address are not acceptable The detector shall also store an internal identifying that the control panel shall use to identify the type of detector Systems that require a programmer to set the detector address including temporary connection at the panel are intensive and not acceptable Each detector occupies any one of at least 159 possible on the signaling line circuit SLC loop It responds to regular polls from the system reports its type and status detector shall provide a test means whereby it will simulate an alarm condition and report condition to the control panel Such a test may be initiated at the detector itself by activating switch or initiated remotely on command from the control panel There shall be four test functional magnet smoke entry aerosol carbon monoxide aerosol or direct heat detector shall provide two LEDs to provide 360 visibility The LEDs shall be placed into red illumination by the control panel indicating that an alarm condition has been detected output connection shall also be provided in the base to connect an external remote alarm The detector must be capable of connecting to a sounder base that provides both temporal and temporal 4 patterns for fire and CO alarm LEDs on the sensor shall be controlled by the panel to indicate sensor status Coded transmitted from the panel shall cause the LEDs to blink latch on or latch off Refer to 2011 control panel technical documentation for sensor LED status operation and expected delay to detector shall be plug in mounted into a twist lock base The detector shall be constructed of UV resistant polymer and shall be detachable from the mounting base to simplify service and maintenance Mounting base wiring connections shall be made by means SEMS screws The detector shall allow pre wiring of the base and the head shall be a plug in The mounting base shall be mounted on a junction box that is at least 1.5 inches 3.81 cm The mounting base shall be available to mount to standard junction boxes boxes include 10.16 cm square box with and without plaster ring 10.16 cm octagonal box 8.89 cm octagonal box box box agency standards 268 Smoke Detectors for Fire Alarm Signaling Systems Smoke Detectors for Fire Alarm Systems 3230 3250 Smoke Actuated Detectors for Automatic Fire Alarm Signaling 2075 Gas and Vapor Detector and Sensors Systems Connected 2011

Related Files