System Sensor B110LP Manual

File Preview
File Preview
Click below to download for free

File Data

Name system-sensor-b110lp-manual-4396518207.pdf
Type PDF
Size 1.27 MB
Downloads

Text Preview

INSTALLATION AND MAINTENANCE INSTRUCTIONS Plug in Detector Base use with the following smoke detectors US CANADA EUROPE 2151 2151A 2151E 3825 Ohio Avenue St Charles Illinois 60174 FAX 630 377 6495 Diameter Height Temperature Range Humidity Range Ratings includes base and detector Voltage Ripple Voltage Capacitance Ratings Ratings Voltage Time Time inches 157 mm inches 24 mm lb 137 g square box with or without plaster ring Min depth inches octagon box Min depth inches to 49 32 to 120 to 93 Relative Humidity Noncondensing VDC Volts peak to peak Maximum VDC Minimum VDC Maximum Maximum VDC Minimum at 10 mA VDC Maximum at 100 mA Alarm current must be limited to 100 mA 130 mA for models 1151 and 2151 by the control panel If it is used the RA400Z Annunciator operates within the specified detector alarm currents VDC Minimum Seconds Minimum Seconds Maximum 1 MOUNTING BASE TO BOX ON INSTALLING thoroughly read the System Smoke Detectors Application Guide which detailed information on detector spacing placement zoning wiring and applications Copies of this manual are available at no charge from System For installation in Canada please refer to CAN ULC S524 Standard for the of Fire Alarm Systems and CEC Part 1 Sec 32 This manual should be left with the owner user of this equipment The detector used with this base must be tested and maintained regu following NFPA 72 requirements The detector used with this base should be at least once a year DESCRIPTION Model B110LP detector base is designed for use with System Sensor models photoelectronic and 1151 ionization detector heads This two wire base is with screw terminals for the connection of power ground and an optional annunciator detector base mounts directly to 3 inch and 4 inch octagon boxes and 4 inch boxes with or without plaster rings To mount the base remove the decorative by rotating it in either direction to unhook the snaps before separating the ring the base Use the screws supplied with the junction box to attach the base to the through the appropriate slots in the base see Figure 1 Position the decorative around the base and rotate it in either direction until the ring snaps into place GUIDELINES loop resistance is an important specification for control panels as well as smoke detectors and their bases The alarm system cannot be expected to oper correctly if system components have incompatible allowable loop resistances before beginning installation refer to the control panel manufacturer resistance specification to ensure that it is listed as compatible with the System base and smoke detector being installed Sensor smoke detectors and mounting bases are marked with a compatibility as the last digit of a five digit code stamped on the back of the product detectors only to compatible control units as indicated in System Sensor chart This chart consists of a current list of UL listed control unit combinations and is available from System Sensor upon request wiring must be installed in compliance with the National Electrical Code and all local codes and any special requirements of the authority having jurisdic SUPPLIED SUPPLIED using the proper wire size The conductors used to connect smoke detectors to panels and accessory devices should be color coded to reduce the likelihood wiring errors Improper connections can prevent a system from responding prop in the event of a fire signal wiring the wiring between interconnected detectors it is recommended the wire be no smaller than AWG 18 However the screws and clamping plate in base can accommodate wire sizes up to AWG 12 The use of twisted pair wiring the power and loop is recommended to minimize the effects of electrical To ensure that electrical connections are supervised do NOT loop wires un terminals 2 3 and 5 break the wire at each terminal make electrical connections strip approximately 3 8 cm insulation from the of each wire Slide the wires under the clamp plate and tighten the terminal screw the zone wiring before installing the smoke detector head The built in short spring makes it convenient to do this After the detector base is wired and at to the electrical box position the shorting spring against terminal 3 Use the in the retaining clip to hold the spring against the terminal as shown in Figure 1 shorts the negative in and negative out leads so that loop wiring can be tested continuity shorting spring in the base will disengage automatically when the detector head removed from the base DO NOT remove the shorting spring since it reengages as detector head is turned into the base completing the circuit FEATURE DO NOT use the tamper resistance feature if the System Sensor XR2 Re Tool will be used to remove detectors from the base detector base can be made tamper resistant so that the detector cannot be de without the use of a tool To make the base tamper resistant break off the tab at the scribed line on the tamper resistance tab on the detector mounting see Figure 3A before installing the detector remove the detector from the base after it has been made tamper resistant remove decorative ring by rotating it in either direction and pulling it away from the base insert a small screwdriver into the notch see Figure 3B and press the plastic toward the mounting surface before rotating the detector counterclockwise for LEVER TAB AT DOTTED LINE BY TOWARD CENTER OF BASE 2 WIRING DIAGRAM FOR A TYPICAL 2 WIRE DETECTOR SYS A OPTIONAL WIRING If a remote annunciator is not used polarity of these terminals be reversed 3A ACTIVATING THE TAMPER RESISTANCE FEATURE LEVER TAB AT DOTTED LINE BY TOWARD CENTER OF BASE 3B REMOVING DETECTOR HEAD FROM BASE SMALL BLADED SCREWDRIVER TO PUSH LEVER IN DIRECTION OF ARROW LIMITED WARRANTY Sensor warrants its enclosed smoke detector base to be free from defects in ma and workmanship under normal use and service for a period of three years from of manufacture System Sensor makes no other express warranty for this smoke base No agent representative dealer or employee of the Company has the au to increase or alter the obligations or limitations of this Warranty The Company of this Warranty shall be limited to the repair or replacement of any part of smoke detector base which is found to be defective in materials or workmanship normal use and service during the three year period commencing with the date of After phoning System Sensor toll free number 800 SENSOR2 736 7672 a Return Authorization number send defective units postage prepaid to Honeywell Rojas Drive Suite 700 El Paso TX 79936 USA Please include a note describing the and suspected cause of failure The Company shall not be obligated to repair replace units which are found to be defective because of damage unreasonable use or alterations occurring after the date of manufacture In no case shall the be liable for any consequential or incidental damages for breach of this or any Warranty expressed or implied whatsoever even if the loss or damage is caused by Company negligence or fault Some states do not allow the exclusion or limitation of or consequential damages so the above limitation or exclusion may not apply you This Warranty gives you specific legal rights and you may also have other rights vary from state to state System Sensor 04 21

Related Files