System Sensor B112LP Manual
File Preview
Click below to download for free
Click below to download for free
File Data
Name | system-sensor-b112lp-manual-2736481905.pdf |
---|---|
Type | |
Size | 1.15 MB |
Downloads |
Text Preview
INSTALLATION AND MAINTENANCE INSTRUCTIONS Plug in Detector Base use with the following smoke detectors US CANADA 1151A 2151A EUROPE 2151E 2151 3825 Ohio Avenue St Charles Illinois 60174 FAX 630 377 6495 inches 157 mm inches 24 mm lb 137 g square box with or without plaster ring Min depth inches octagon box Min depth inches to 49 32 to 120 to 93 Relative Humidity Noncondensing VDC Volts peak to peak Maximum VDC Minimum VDC Maximum Maximum mA Minimum mA Maximum VDC Minimum Seconds Maximum optional RA400Z operates within specified detector alarm currents Seconds Maximum Diameter Height Temperature Range Humidity Range Ratings includes base and detector Voltage Ripple Voltage Capacitance Ratings Ratings Voltage Time Time Contact Ratings or Inductive 60 Power Factor A C A 30 VAC DC A 30 VAC DC A 110 VDC A 125 VAC Installing read thoroughly System Sensor Applications Guide System Smoke Detectors SPAG91 which provides information on detector spacing placement wiring and special applications This manual is online at www systemsensor com For installa in Canada refer to CAN ULC S524 Standard for the of Fire Alarm Systems and CEC Part 1 Sec 32 This manual should be left with the owner user this equipment The detector used with this base must be and maintained regularly following NFPA 72 require The detector used with this base should be cleaned least once a year Description Model B112LP detector base is designed for use with Sensor model 2151 photoelectronic and 1151 ioniza detector heads This four wire base is equipped with terminals for the connection of power ground and optional remote annunciator detector base mounts directly to 3 1 2 inch and 4 inch boxes and 4 inch square boxes with or without rings To mount the base remove the decorative by rotating it in either direction to unhook the snaps separating the ring from the base Use the screws with the junction box to attach the base to the through the appropriate slots in the base see Figure Position the decorative ring around the base and rotate in either direction until the ring snaps into place Guidelines Refer to the releasing device manufacturer for connection instructions loop resistance is an important specification for panels as well as for smoke detectors and their The alarm system cannot be expected to operate if system components have incompatible allow loop resistances Therefore before beginning installa refer to the control panel manufacturer loop resis specification to ensure that it is listed as compatible the System Sensor base and smoke detector being wiring must be installed in compliance with the Electrical Code all applicable local codes and any requirements of the authority having jurisdiction the proper wire size The conductors used to connect detectors to control panels and accessory devices be color coded to reduce the likelihood of wiring Improper connections can prevent a system from properly in the event of a fire signal wiring the wiring between interconnected it is recommended that the wire be no smaller AWG 18 However the screws and clamping plate in base can accommodate wire sizes up to AWG 12 The of twisted pair wiring for the power and loop is to minimize the effects of electrical interfer make electrical connections strip approximately 3 8 1 insulation from the end of each wire Slide the wires the clamp plate and tighten the terminal screw the base is being installed in a zoned system check the wiring before installing the smoke detector head The shorting spring makes it convenient to do this the detector base is wired and attached to the electri box position the shorting spring against terminal 3 Use slot in the retaining clip to hold the spring against the as shown in Figure 1 This shorts the negative in negative out leads so that loop wiring can be tested continuity shorting spring in the base will disengage automati when the detector head is removed from the base NOT remove the shorting spring since it reengages as detector head is turned into the base completing the 1 Mounting base to box ON SUPPLIED SUPPLIED DO NOT use the tamper resistance feature if the Sensor XR2 Removal Tool will be used to detectors from the base detector base can be made tamper resistant so the cannot be removed without the use of a tool To the base tamper resistant break off the smaller tab at scribed line on the tamper resistance tab on the detec mounting bracket see Figure 3A before installing the remove the detector from the base after it has been made resistant remove the decorative ring by rotating it either direction and pulling it away from the base Then a small screwdriver into the notch as indicated in 3B and press the plastic lever toward the mounting before rotating the detector counterclockwise for To ensure that electrical connections are super DO NOT loop wires under terminals 2 3 5 the wire at each terminal Feature RELAY CONTACTS VDC 4 RELAY CONTACTS VDC 4 Schematic for RELAY 2 OUT 2 OUT LOOP LOOP RELAY RELAY DETECTOR IN LOOP DETECTOR IN LOOP PANEL 2 Typical wiring diagram 9 10 9 10 RELAY LOOP LOOP CIRCUIT LEVER 3A Activating the tamper resistance feature 3B Removing detector head from base SMALL BLADED SCREWDRIVER TO PUSH LEVER IN DIRECTION OF ARROW TAB AT DOTTED LINE BY TOWARD CENTER OF BASE refer to insert for the Limitations of Fire Alarm Systems LIMITED WARRANTY Sensor warrants its enclosed smoke detector base to be free from in materials and workmanship under normal use and service for a of three years from date of manufacture System Sensor makes no express warranty for this smoke detector base No agent represen dealer or employee of the Company has the authority to increase alter the obligations or limitations of this Warranty The Company of this Warranty shall be limited to the repair or replacement any part of the smoke detector base which is found to be defective materials or workmanship under normal use and service during the year period commencing with the date of manufacture After phon System Sensor toll free number 800 SENSOR2 736 7672 for a Authorization number send defective units postage prepaid to 12220 Rojas Drive Suite 700 El Paso TX 79936 USA Please a note describing the malfunction and suspected cause of failur