System Sensor B116LP
File Preview
Click below to download for free
Click below to download for free
File Data
Name | system-sensor-b116lp-9428361507.pdf |
---|---|
Type | |
Size | 1.14 MB |
Downloads |
Text Preview
I Ohio Avenue St Charles Illinois 60174 FAX 630 377 6495 AND MAINTENANCE INSTRUCTIONS Plug in Detector Base use with the following smoke detectors US Canada Europe 2151 2151A 2151E Diameter Height Temperature Range Humidity Range Ratings includes base and detector Voltage Ripple Voltage Capacitance Ratings Ratings Contact Ratings or Inductive 60 power factor Load C Voltage Time Time Canadian installations relay contact ratings are 2.0A 30 VAC DC 30 VAC DC 110 VDC 125 VAC VDC Minimum Seconds Maximum Seconds Maximum inches 157 mm inches 24 mm lb 130 g square box with or without plaster ring Min Depth inches octagon box Min Depth inches inch octagon box Min Depth inches mm box mm box mm box to 49 32 to 120 US and Canadian Installations to 60 14 to 140 European Installations to 93 Relative Humidity VDC Volts peak to peak Maximum VDC Minimum VDC Maximum Maximum V Minimum at 16 mA V Maximum at 100 mA current MUST be limited to 100 mA maximum by the control panel Installing read thoroughly System Sensor Applications Guide System Smoke Detectors which provides detailed infor on detector spacing placement zoning wiring special applications Copies are available on System web site www systemsensor com For installa in Canada please refer to CAN4 S524 Standard for the of Fire Alarm Systems and CEC Part 1 Sec 32 This manual should be left with the owner user this equipment The detector used with this base must be and maintained regularly following NFPA 72 require The detector used with this base should be cleaned least once a year Description model B116LP plug in detector base is used with Sensor model 1151 1151A and 1151E ionization heads and model 2151 2151A and 2151E photo detector heads The capability of plugging these into a variety of special bases makes them more than equivalent direct wired models Refer to the Sensor catalog for other available plug in detector B116LP base is intended for use in 2 wire systems screw terminals provided for power and relay contact These bases MUST be current limited by the control panel in the alarm state detector base mounts directly to 3 1 2 inch and inch octagon boxes and 4 inch square boxes with or plaster rings To mount remove decorative ring turning it in either direction to unhook the snaps then the ring from the base Install the base to the box the screws supplied with the junction box and the mounting slots in the base Place decorative onto base then turn in either direction until the ring in place see Figure 1 Guidelines wiring must be installed in compliance with the Electrical Code and the local codes having juris Proper wire gauges should be used The conduc used to connect smoke detectors to control panels and devices should be color coded to prevent wiring Improper connections can prevent a system from properly in the event of a fire signal wiring the wiring between inter connected it is recommended that the wire be no smaller 18 gauge Wire sizes up to 12 gauge may be used with base For best system performance the power and loop wires should be twisted pair and installed in sepa grounded conduit to protect the loop from extraneous interference detectors and alarm system control panels have for allowable loop resistance Consult the panel manufacturer specifications for the total resistance allowed for the particular model control being used before wiring the detector loops installations where normal ambient temperatures not exceed 100 Instructions system supervision For terminals 2 3 and 5 do not looped wire under terminals Break wire run to provide supervision of connections connections are made by simply stripping insulation the end of the wire sliding the bare end of the wire the clamping plate and tightening the clamping screw Use the strip gauges molded into the inside 1 Mounting base to box ON SUPPLIED SUPPLIED underside of the base for ease of wiring to terminals 1 5 and to terminals 12 through 14 respectively Sensor smoke detectors and mounting bases are with a compatibility identifier located as the last of a five digit code stamped on the back of the prod Connect detectors mounting bases only to compatible units as indicated in System Sensor compatibility which contains a current list of UL listed control units detector head base combinations A copy of this list is from System Sensor upon request zone wiring of the detector base should be checked the detector heads are installed in them To make possible this base contains a special spring type short jumper After a detector base is properly wired and on an electrical box make sure that the jumper is in contact with the base of Terminal 3 This tem connection shorts the positive in and positive out and permits the wiring of the loop to be checked for 2 Typical wiring diagram POWER LOOP CONTACT AUXILIARY FORM C POWER LOOP A OPTIONAL WIRING feature has been activated place a small bladed into the small hole on the side of the base and plastic lever away from the detector head see Figure This will allow the detector to be rotated counterclock for removal Head removal after the tamper resistance feature been activated requires removal of the decora ring tamper resistance feature can be defeated by breaking removing the plastic lever from the base however this using the feature again all the detector bases have been wired and mounted the loop wiring has been checked the detector heads be installed in the bases The shorting spring in the will disengage automatically when the detector head removed from the base DO NOT remove the short spring since it reengages as the detector head is fully into the base completing the circuit Feature NOT use the tamper resistance feature if the XR2 Tool will be used detector base includes a tamper resistance feature that removal of the detector without the use of a tool activate this feature break off the tab on the detec base shown in Figure 3A then install the detector remove the detector from the base once the tamper 3A Activating tamper resistance feature 3B Removing detector head from base LEVER SMALL BLADED SCREWDRIVER TO PUSH LEVER IN DIRECTION OF ARROW TAB AT DOTTED LINE BY TOWARD CENTER OF BASE refer to insert for the Limitations of Fire Alarm Systems LIMITED WARRANTY Sensor warrants its enclosed smoke detector base to be free from in materials and workmanship under normal use and service for a of three years from date of manufacture System Sensor makes no express warranty for this smoke detector base No agent represen dealer or employee of the Company has the authority to increase alter the obligations or limitations of this Warranty The Company of this Warranty shall be limited to the repair or replacement any part of the smoke detector base which is found to be defective materials or workmanship under normal use and service during the year period commencing with the date of manufacture After phon System Sensor toll free number 800 SENSOR2 736 7672 for a Authorization number send defective units postage prepaid to 12