System Sensor B200S and B200S-LF
File Preview
Click below to download for free
Click below to download for free
File Data
Name | system-sensor-b200s-and-b200s-lf-0749651382.pdf |
---|---|
Type | |
Size | 751.48 KB |
Downloads |
Text Preview
B200S B200S LF Bases Sensor B200S series sounder bases set a standard for performance installation ease aesthetics Series Features Addressability for maximum configuration flexibility Two volume levels 75 or 85 dBA Multiple event driven tone outputs Supports Continuous ANSI Temporal 3 ANSI Temporal 4 March Time tones Custom tone capability with some FACP models Ability to synchronize with other System Sensor devices UL 268 and UL 464 compliant Pre wire mounting plate fits various junction box sizes Mechanical locking feature prevents removal of attached head silence feature Additional terminal connections on Canadian model B200SA 520 Hz 10 square wave tone B200S LF Listings B200S sounder base series is designed for new and existing unit applications It offers maximum flexibility in installation and operation to meet or exceed UL 268 and UL 464 sounder base in to the communication between the sensor head and the fire alarm control panel FACP to the same address as the detector but as a unique device on the loop The FACP can then use that address to command individual sounder or a group of sounders to activate The set from the panel can be tailored to the specific event selection of volume tone and group In addition some will enable custom tone patterns B200S series sounder bases recognize the System Sensor protocol This enables it to be used as a component the general evacuation signal along with other System Sensor horn strobes and chimes when connected to a power or FACP output capable of generating the System Sensor pulses B200S series offers several key advantages The sounder base a separate mounting plate that installs on various junction sizes to eliminate unsightly surface mount boxes The mounting enables pre wiring of all connections to speed and simplify The housing also locks with the mounting plate using two screws for added tamper resistance B200S LF low frequency sounder base is designed to meet NFPA 72 sleeping space requirement to produce a fundamental of 520 Hz 10 with a square wave or its equivalent show that a lower frequency centered around 520 Hz is the ideal to awaken sleeping occupants even those with mild to hearing loss 7135 1653 0213 7300 1653 0238 to the appropriate FACP manual for more information Specifications Diameter Height Weight Temperature Range Humidity Range Specifications B200S Supply Voltage Supply Standby Current Current Operating Voltage Standby Current Specifications B200S LF Supply Voltage Supply Standby Current Current 17.46 cm 5.08 cm less sensor 0.50 lb 227 gm B200S LF 0.60 lb 272 gm to applicable sensor Operating Temperature Range using the Base Sensor Cross Reference at systemsensor com to 93 relative humidity non condensing to 33 VDC VFWR maximum mA maximum at high volume setting 15 mA maximum at low volume setting to 32 VDC maximum base only refer to applicable sensor specification to 33 VDC VFWR maximum volume setting 70 mA maximum 33.0 VDC mA maximum 24.0 VDC mA maximum 16.0 VDC volume setting 15 mA maximum 33.0 VDC mA maximum 24.0 VDC mA maximum 16.0 VDC Operating Voltage Standby Current Output Volume Volume to 32 VDC maximum base only refer to applicable sensor specification than 85 dBA minimum measured in a UL reverberant room at 10 ft 24 Volts continuous tone than 75 dBA minimum measured in a UL reverberant room at 10 ft 24 Volts continuous tone Ohio Avenue St Charles IL 60174 800 SENSOR2 Fax 630 377 6495 specifications subject to change without notice Visit systemsensor com current product information including the latest version of this data sheet System Sensor 02 15