System Sensor BEAM Detectors
File Preview
Click below to download for free
Click below to download for free
File Data
Name | system-sensor-beam-detectors-2630178459.pdf |
---|---|
Type | |
Size | 986.38 KB |
Downloads |
Text Preview
BEAM1224 S Reflected Beam Smoke BEAM1224 S is uniquely suited for protecting open with high ceilings areas where other methods of detection are difficult to install and maintain 16 to 328 foot protection range Single ended reflective design User friendly alignment procedure Six user selectable sensitivity levels Optional integral NFPA 72 sensitivity test feature Removable plug in terminal blocks Digital display for easy alignment Built in automatic gain control compensates for signal from dust build up Remote test station option Paintable cover Easiest alignment in the industry Heater kits for transmitter receiver and reflector option Listings Sensor Model BEAM1224 is a four wire conventional beam smoke detector which is uniquely suited for open areas with high ceilings where other methods of detection are difficult to install and maintain It is to be used UL Listed compatible control panels only An advantage of this reflective design is that it is much easier to install than dual ended projected beam detectors Alignment is quickly via an optical sight and a two digit signal strength incorporated into the product Another advantage of the is that it is listed for operation in temperatures ranging to 131 This means it can be used in open areas to early warning in environments where temperature extremes exceed the capability of other types of smoke detectors consists of a transmitter receiver unit and a reflector smoke enters the area between the unit and the reflector smoke causes a reduction in the signal When the smoke level the predetermined threshold an alarm is activated has four standard sensitivity selections along with two settings adjustable sensitivity When one of the two settings is selected the detector will automatically adjust sensitivity using advanced software algorithms to choose the sensitivity for the specific environment is also equipped with an integral sensitivity test feature consists of a test filter attached to a servo motor inside the optics When the remote test station RTS451 RTS151 is the motor is activated and moves the filter into the pathway the light beam to test the detector sensitivity This integral test feature allows the user to quickly and easily meet the maintenance and test requirements of NFPA 72 Specifications Specifications Range Angle Levels Condition Trouble Aid Indicator Indicator Indicator Features ft to 328 ft 5m to 100m 10 Degrees horizontal vertical optics move independent of the unit 1 25 2 30 3 40 4 50 Level 1 30 Level 2 40 or more obscuration blockage alignment mode initial alignment limit reached gunsight signal strength indication display red LED and remote alarm yellow LED and remote trouble flashing green LED Sensitivity Test Filter BEAM1224S only filter Incremental scale on reflector alarm test switch alarm reset switch test and reset switch Compatible with RTS451 and RTS451KEY RTS151KEY test station beams and not more than one half spacing between a projected beam and a Other spacing may be used depending ceiling height airflow characteristics and requirements See NFPA 72 Detector Spacing On smooth ceilings 30 feet between Specifications BEAMHKR Consumption Parts to 32V Max at 32V per reflector 24V 15W 32V per reflector Terminals Test Feature only MOTOR COM N O COM N O OUT OUT IN IN INPUT INPUT ALARM OUT used TROUBLE OUT COM N C FILTER Specifications Specifications Standby Current 24VDC Current During Testing Alarm Current 24VDC Fault Current 24VDC Alignment Mode Current Specifications Dimensions Dimensions 16 to 230 Dimensions 230 Specifications BEAMHK Consumption to 131 to 55 RH Noncondensing to 32 VDC BEAM1224 to 32 VDC BEAM1224S should not be used 12V power sources Max Max Max Max Max H 7.5 W 3.3 D H 191mm W 84mm D 9.1 200 230mm 18.1 400 460mm to 32V at 32V 24V 3W 32V Information No conventional beam smoke detector with 8 reflector conventional beam smoke detector with 8 reflector integral sensitivity test RTS151 range accessory kit 3 additional reflectors for applications in excess of 230 ft 70 m kit Provides ceiling or wall mount capability increased angular adjustment for either the beam or reflector When installed with the transmitter receiver BEAMSMK must be used as well mount kit for use with BEAMMMK duty multi mount kit for installations prone to or where there is difficulty in maintaining the set When installed with the transmitter receiver unit must be used as well mount kit for use with the 6500 MMK kit for transmitter receiver unit See electrical above kit for reflector See electrical requirements above test station with key lock test station Ohio Avenue St Charles IL 60174 800 SENSOR2 Fax 630 377 6495 specifications subject to change without notice Visit systemsensor com current product information including the latest version of this data sheet System Sensor 11 11