System Sensor CD100VC Manual
File Preview
Click below to download for free
Click below to download for free
File Data
Name | system-sensor-cd100vc-manual-6807531924.pdf |
---|---|
Type | |
Size | 1.54 MB |
Downloads |
Text Preview
CD100VC Ventilation Controller Manual the on the by aligning top clips and securing to bottom clips A sound will that the is secure sensor will have power for for installation by the mounting holes for US or junction boxes the mounting plate a template to mark and wiring less than 2 minutes the will stabilize and display Mode current readings this point one of nine programs or one channel can be for operation Use charts below to select a or to select modify settings the Mounting Plate to wall or junction box and necessary wire Block Designations Not Used Not Used Relay Norm Open Relay Common Relay Norm Closed 4 20mA Output Signal Ground 0 10V Output AC DC AC GND installation by the cover over menu keys and with the screw Operation new Innovair CD100VC CO2 Ventilation Controller uses state of the art beam Absorption Infrared Technology This patented technology a stable accurate and reliable sensor sensor is also equipped with Engelhard Sensor Technologies patented Time Extended Measurement Algorithm software The TEMA software automatically sense and adjust for any sensor drift minimizing calibration to once every five years Ventilation Controller is shipped with 9 preset settings named Standard and one setting for customizing named Non Standard Two additional are available altitude adjustments and TEMA on off These two are without entering the Standard or Non Standard settings Correction and TEMA On Off Press and hold at least 5 seconds until the sensor enters the mode The first menu will be the Altitude correction The adjustments will in in 500 ft increments To do this use the Up Down Rocker to adjust to the proper altitude Press to lock in value then press to proceed to TEMA Use the Up Down Rocker Button to switch to On or Off Press to lock in value then press proceed to Normal Mode It is recommended that the TEMA feature is left on for the best operation and Non Standard Settings Non Standard settings can be changed at any time after the sensor is up These settings have 7 variables and follow in sequence with the chart see reverse side of this sheet The Altitude and TEMA can be changed without entering into the Non Standard mode Standard Settings see reverse side of this sheet are factory set and be changed Like the Non Standard settings Altitude and TEMA can be a Preset from the STDSET Menu Press and hold at least 5 seconds until the sensor enters the mode Press 2 times You will enter the Menu Use the Up Down Rocker Button to select the Preset number Use the chart on reverse side of this sheet to select the desired Press to lock in selection then press to return to monitoring mode Custom Settings from the NONSTD Menu Press and hold at least 5 seconds until the sensor enters the mode Press 2 times You will enter the Menu Use the Up Down Rocker Button to toggle to the Menu and Use the Up Down Rocker Button to scroll through the 8 variables The begin with customizing the ppm levels and end with hysterisis Press to move through variables Use the Up Down Rocker to toggle to setting Press to lock in selection then press to continue to next Variable Functionality Beam Absorption Infrared TEMA self calibration Method or flow through 50 100 ml min Range output 0 2000 ppm factory Adjustable to 10,000 ppm display 0 10,000 ppm ppm ppm Conditions 50 cid 176 C 32 cid 176 122 cid 176 F 95 RH non condensing Temperatures 70 cid 176 C Certification Part 15 Class B Interval years zero ppm gas offset adjust conditions 60 90 cid 176 F 15 32 cid 176 C ppm ppm or of whichever is greater ppm of reading conditions 0 50 cid 176 C ppm ppm or of whichever is greater ppm of reading Pressure Correction 0.13 of reading per mm Hg from 760 On board user set Drift ppm negligible with TEMA on ppm typical with TEMA off Time 0 90 FS min Time 25 cid 176 C minutes VAC RMS 50 60 Hz VDC polarity protected dependent mA average 100 mA peak at 24 VDC CO2 Output VDC 100 Ohms output impedance mA RLmax 500 Ohms outputs available simultaneously Open or Normally Closed wire way gold bifurcated 1 Amp at 24 resistive load 2 Amp carrying Adjustable setpoint factory set 1000 ppm 50 ppm hysteresis AWG stranded copper wire only wires each for power analog output I O interface readings may be temporarily in the presence of certain por two way radios and cellular phones subject to change without Covered by United States 5,060,508 and 5,163,332 patents pending Sensor warrants its enclosed sensor to be free from defects in materials and workmanship under normal use and service for a period of 18 months from date of purchase by the owner System Sensor makes no other express warranty for this sensor No agent representative dealer or employee of the Company has the authority to increase or alter the or limitations of this Warranty The Company obligation of this Warranty shall be limited to the repair or replacement of any part of the sensor which is found to be defective in or workmanship under normal use and service during the 18 month period commencing with the date of purchase by the original owner After phoning System Sensor toll free 800 SENSOR2 736 7672 for a Return Authorization number send defective units postage prepaid to System Sensor Warranty Service RA 3825 Ohio Avenue St IL 60174 Please include a note describing the malfunction and suspected cause of failure The company shall not be obligated to repair or replace units which are found to be because of damage unreasonable use modifications or alterations occurring after the date of manufacture In no case shall the Company be liable for any consequential or damages for breach of this or any other Warranty expressed or implied whatsoever even if the loss or damage is caused by the limitation of incidental or consequential so the above limitation or exclusion may not apply to you This Warranty gives you specific legal rights and you may also have other rights and you may also have other rights may vary from state to state Sensor Ohio Avenue St Charles IL 60174 736 7672 Fax 630 377 6495 Infrared is a trademark of Engelhard Sensor Technologies is a registered trademark of Engelhard Sensor Technologies 31300