COSMOD4W Interface Module Specification Specifications i4 module shall be a System Sensor i4 Series model number COSMOD4W listed to UL 864 and UL 975 for Control for Fire Protection Signaling Systems The module shall include provisions for mounting to 4 inch square back box connections shall be made by means of SEMS screws The module shall provide 4 LED indicators that blink or to indicate communication status maintenance alert alarm or freeze trouble conditions and EZ Walk loop test 2 wire module only The module shall allow communication to i4 Series and i3 Series detectors with any UL 864 UL 975 listed fire alarm control panel capable of utilizing this module The 2 wire module shall offer provisions for D wiring on IDC loops and shall provide a loop testing capability EZ Walk to verify the initiating loop wiring Specifications Operating Voltage shall be Nominal 12 24V non polarized Minimum 10V Maximum 35V power limited The Maximum Ripple shall be 30 peak to peak of applied voltage The Standby Current shall be 48 mA maximum Does not include current draw attached detectors or EOL relay The Maximum Alarm Current shall be 75 mA module current only does not include reverse current draw from attached detectors The Alarm Contact Ratings shall be 100 mA 36VDC resistive The loop wiring shall be 300 Ohms Specifications COSMOD4W dimensions shall be 6.04 inches 140 mm diameter 6.04 inches 154 mm height 1.0 inches 25.4 depth The approximate weight shall be 9.6 oz 272 grams The COSMOD4W detector Operating Temperature shall be 14 10 The COSMOD4W Operating Humidity Range shall be 5 to 95 RH non The COSMOD4W Input Terminals shall be 14 AWG options for the COSMOD4W include 4 11 16 square back box or placement inside a metal enclosure Modes Power up the Green LED shall blink every 5 seconds In Normal standby mode the Green LED shall blink every 5 the Yellow LED shall be off the Red LED shall be off the Blue LED shall be off In Smoke Alarm mode the LED shall be off the Yellow LED shall be off the Red LED shall be solid the Blue LED shall be off In CO Alarm the Green LED shall be off the Yellow LED shall be off the Red LED shall be off the Blue LED shall be solid In Alarm and CO Alarm mode the Green LED shall be off the Yellow LED shall be off the Red LED shall be solid Blue LED shall be solid In Smoke Trouble mode the Green LED shall blink every 5 seconds the Yellow LED shall off the Red LED shall blink every 5 seconds the Blue LED shall be off Smoke Freeze Trouble mode the Green shall blink every 5 seconds the Yellow LED shall be off the Red LED shall blink every 10 seconds the Blue LED be off In CO Trouble mode the Green LED shall blink every 5 seconds the Yellow LED shall be off the Red LED be off the Blue LED shall blink every 5 seconds In Loop Wiring Fault condition the Green LED shall be off Yellow shall be solid the Red LED shall be off the Blue LED shall be off EZ Walk Test mode the Green LED shall blink 5 seconds the Yellow LED shall blink every 5 seconds the Red LED shall be off the Blue LED shall be off