System Sensor CR-6 Manual

File Preview
File Preview
Click below to download for free

File Data

Name system-sensor-cr-6-manual-3061742598.pdf
Type PDF
Size 1.32 MB
Downloads

Text Preview

INSTALLATION AND MAINTENANCE INSTRUCTIONS Ohio Avenue St Charles Illinois 60174 FAX 630 377 6495 Six Relay Control Module Operating Voltage Current Current Range Gauge Current 15 32 VDC 1.90 mA 24V 32 mA assumes all six relays have been switched once and all six LEDs solid on 32 to 120 0 to 49 10 to 93 Non condensing 6.8 5.8 1.0 BB 2 Cabinet BB 6 Cabinet CH 6 Chassis 12 18 AWG 30 mA Relay Pulse 15.6 mS pulse duration pulse under panel control CONTACT RATINGS RATING VOLTAGE DESCRIPTION A A A A A A A A VAC VDC VDC VDC VAC VDC VAC VAC 20ms 0.35 0.35 0.75 0.35 relay switch contacts are shipped in the standby state open state but may have transferred to the activated closed state during shipping To ensure that switch contacts are in their correct state modules must be made to communicate with the panel before connecting circuits controlled by the module INSTALLING information is included as a quick reference installation guide If the will be installed in an existing operational system inform the op and local authority that the system will be temporarily out of service the power to the control panel before installing the modules This contains static sensitive components Always ground yourself with a wrist strap before handling any circuits so that static charges are re from the body The housing cabinet should be metallic and suitably This manual should be left with the owner user of this equipment DESCRIPTION CR 6 Six Relay Control Module is intended for use in an intelligent alarm Each module is intended for Form C switching applications which do require wiring supervision for the load circuit A single isolated set of dry contacts is provided for each module which is capable of being wired either normally open or normally closed for each operation Each module its own address A pair of rotary code switches is used to set the address the first module from 01 to 94 The remaining modules are automatically as to the next five higher addresses Provisions are included for disabling maximum of three unused modules to release the addresses to be used else Each CR 6 module also has panel controlled green LED indicators The can cause the LEDs to blink latch on or latch off INCLUDE 1 x 3 Terminal Blocks 1 x 4 Terminal Blocks 1 32mm Stand offs Machine Screws Nuts Shunt NOTE For the disable position not more than one shunt shall be at the same time REQUIREMENTS ensure proper operation this module shall be connected to a compatible panel only are descriptions of the CR 6 mounting frameworks There are two options for CR 6 modules Up to six CR 6 modules can be installed on a CH 6 in a BB 6 cabinet One or two CR 6 modules can be installed in a BB 2 cabinet CH 6 chassis is used to mount CR 6 modules in a BB 6 cabinet It accom up to six CR 6 modules in a single cabinet row three modules wide two modules deep 1 CH 6 CHASSIS a clean dry area mount the backbox using the four holes provided in the surface of the cabinet Chassis Installation CH 6 chassis is mounted in the BB 6 cabinet It is shipped with two self screws which are used to fasten the chassis to the back wall of the see Figure 4 4 MOUNTING THE CH 6 CHASSIS BB 2 cabinet has a built in chassis that will accommodate one or two modules 2 BB 2 CABINET WITH SCREWS BACK OF CABINET BB 2 cabinet comes with the chassis already installed so no mounting necessary Module Installation are two methods for installing a module in the rear position of a chas Method one is for installation of a rear module only when no module will installed in front of it Refer to Figure 5 for instructions Method two is for of a rear module when another module will be installed in the position in front of it Refer to Figures 6a and 6b for method two All screws and standoffs are supplied with the modules 5 INSTALLATION OF REAR MODULE ONLY METHOD ONE front CR 6 module positions of each chassis are offset below the rear CR 6 positions so that all of the status indicators are visible BB 6 cabinet will house the CH 6 chassis with up to six CR 6 modules in on it BB 2 cabinet houses one or two CR 6 modules on the internal chassis that part of the cabinet Refer to cabinet installation documents for dimensions STEPS Cabinet Mounting 3 TYPICAL MOUNTING HOLE LOCATIONS 1 Insert the bottom of the CR 6 module down into a rear slot the chassis 2 Carefully swing the upper edge of the board back towards the back of chassis until it touches the two standoffs 3 Align two 4 40 screws with the two standoffs and tighten 4 Address and wire the modules according to the instructions in manual steps in Figures 6a and 6b describe and illustrate module installation the rear chassis position and the position in front of it will be filled position installation is possible only if the rear position is filled with an module Power must not be applied to the unit when changing functionality of shunts All wiring must conform to applicable local codes ordinances and Install module wiring in accordance with the job drawings and appropri wiring diagrams Make electrical connections by stripping approximately 1 4 6.35mm of from the end of the wire sliding the bare end of the wire under clamping plate and tightening the clamping plate screw Set the address on the modules per the job drawing Use the rotary code to set the address of the firstmodule between 01 and 94 The modules are automatically assigned to the next five higher For example if the base address switch is set to 28 the next modules will be addressed to 29 30 31 32 and 33 DO NOT set lowest address above 94 as the other modules will be assigned to addresses A shunt is provided to disable a maximum of three unused modules are disabled from the highest address and work downward If modules are disabled the lowest four addresses will be functional the highest two will be disabled For example if the shunt for Ad Disable is placed on and the base address switch is set to 28 modules will be assigned to 28 29 30 and 31 All references to power limited represent Limited Class 2 6A INSTALLATION OF CR 6 MODULE IN A REAR CHASSIS METHOD TWO 1 Insert the bottom edge of the CR 6 module down into a rear slot of chassis 2 Carefully swing the upper edge of the board towards the back of the until it touches the short standoff attached to the chassis 3 Align the long standoff with the short standoff and tighten 6B INSTALLATION OF CR 6 MODULE IN FRONT CHASSIS POSI 1 Insert the bottom edge of the CR 6 module down into a front slot of chassis 2 Carefully swing the upper edge of the board towards the back of the until it touches the 11 4 31.75mm standoffs installed on the module 3 Align two 4 40 screws with the two standoffs and tighten 4 Address and wire the modules according to the instructions in manual 7 WIRING AND PROGRAMMING THE CR 6 MODULE PANEL PREVIOUS DEVICE LINE CIRCUIT

Related Files