System Sensor DH100 Replacement Manual
File Preview
Click below to download for free
Click below to download for free
File Data
Name | system-sensor-dh100-replacement-manual-9465281370.pdf |
---|---|
Type | |
Size | 711.31 KB |
Downloads |
Text Preview
INSTALLATION AND MAINTENANCE INSTRUCTIONS Series Duct Smoke Detector Detector Board Division of Pittway 3825 Ohio Avenue St Charles Illinois 60174 FAX 630 377 6495 Detector Boards Detector Board part number A5052 2 Wire Detector Board part number A5180 4 Wire Detector Board part number A5190 PHOTOELECTRIC DETECTOR BOARDS CAN ONLY BE INSTALLED IN PHOTOELECTRIC DUCT SMOKE DETECTOR MODELS IONIZATION DETECTOR BOARDS CAN ONLY BE INSTALLED IN IONIZATION DUCT SMOKE DETECTOR MODELS IMPROPER INSTALLATION WILL VOID ALL AGENCY APPROVALS Photoelectric Board Board Replacement Instructions Notify the proper authorities that the smoke detector system is undergoing maintenance and that the detector will temporarily be out of service Turn off power to the duct smoke detector Remove the two detector board mounting screws screws for installation of new board Pull gently on the board to remove it from the detector housing Align the board mounting features holes and interconnect terminals with the features on the duct smoke detector housing Push the board into place Secure the board with the two board mounting screws Ionization Board Perform the detector checks as outlined in sections 6.2.1 and 6.2.2.1 of the Installation and Maintenance to ensure proper detector operation The tests performed must include Visually check to see the green power LED blinks once every ten seconds indicating power to the duct detector If the green LED does not flash the detector lacks power check wiring panel or power the detector board is missing install or the unit is defective return for replacement Perform the magnet test to initiate an alarm condition Reset the detector using the local reset button accessory or system control panel all ionization boards to System Sensor for proper disposal System Sensor 3825 Ohio Avenue St Charles IL 60174 additional assistance in this process or questions please contact System Sensor Technical Service at 800 736 7672 1 I56 1359 01 AND MAINTENANCE INSTRUCTIONS Series Duct Smoke Detector Power Board Division of Pittway 3825 Ohio Avenue St Charles Illinois 60174 FAX 630 377 6495 Power Boards Power Board part number A5061 Power Board part number A5064 TWO WIRE POWER BOARDS CAN ONLY BE INSTALLED IN TWO WIRE DUCT SMOKE DETECTOR MODELS 4 WIRE POWER BOARDS CAN ONLY BE INSTALLED IN 4 WIRE DUCT SMOKE DETECTOR MODELS IMPROPER INSTALLATION WILL VOID ALL AGENCY APPROVALS Power Board Installation Instructions Notify the proper authorities that the smoke detector system is undergoing maintenance and that the detector will temporarily be out of service Turn off power to the duct smoke detector Mark the location of all wires to the terminal block 4 Wire Power Board Disconnect all wiring from the terminal block 2 Wire Power Board Remove the two power board mounting screws Retain screws for installation of new board Pull gently on the board to remove it from the detector housing Align the board mounting features holes and interconnect terminals with the features on the duct smoke detector housing Push the board into place Secure the board with the two board mounting screws Reconnect all wiring to the terminal block Apply power to the duct smoke detector Perform the detector checks as outlined in sections 6.2.1 and 6.2.2.1 of the Installation and Maintenance Instructions to ensure proper detector operation The tests performed must include Visually check to see the green power LED blinks once every ten seconds indicating power to the duct detector Perform the magnet test to initiate an alarm condition Reset the detector using the local reset button accessory removing power or system control panel additional assistance in this process or questions please contact System Sensor Technical Service at 800 736 7672 2 I56 1359 01 System Sensor 2004