System Sensor DH200RPL

File Preview
File Preview
Click below to download for free

File Data

Name system-sensor-dh200rpl-9025861743.pdf
Type PDF
Size 939.54 KB
Downloads

Text Preview

H V A C S Y S T E M S M O N I T O R I N G Low Flow Smoke Detectors Models Available non relay with relay Overview velocity rating from 100 to 4000 feet minute 0.5 to 20.32 m sec telescopic sampling tube accessible code wheels mounting tabs and quick mounting to round rectangular ducts from 1 meters wide to clean recognized field replaceable and sensor boards cover for convenient inspection 268A listed warranty non relay outputs for remote LED display test zener diodes to conserve for communications to other com line power only with relay outputs for remote LED and test and sounder form auxiliary contacts be configured as a relay version or to mimic a non relay version cover tamper trouble signal both com line power and one of following 24VAC DC or for operation System Sensor Innovair DH200 Low Flow Series photoelectric air duct smoke are capable of sensing smoke in air velocities from 100 to 4,000 feet per min 0.5 to 20.32 m sec Innovair features low flow technology that enables duct smoke detection through a broad range of airflow environments Many difficult to solve HVAC applications in low airflow duct applications where reliable smoke detection is critical Innovair technology can detect smoke at air speed velocities of 100 feet per minute or while continuing the same reliable performance to 4,000 feet per minute DH200 Series Detector samples air currents passing through a duct and gives performance for shutdown of fans blowers and air conditioning systems the spread of toxic smoke and fire gases through the protected area intelligent sensors communicate and are continuously monitored through the com line Detector sensitivity changes caused by dirt temperature or humidity reported to the panel allowing compensation algorithms to maintain the sensor set An advance indication at the panel specifies the sensor address allowing for maintenance to be performed as needed alarm annunciation can be accomplished by using the RA400Z Remote or the RTS451 or RTS451KEY Remote Test Station Both these devices testing of the detector from a remote location Innovair family is designed for simplified installation and easy maintenance The construction allows for easy cleaning and uncomplicated field replacement of UL recognized power and sensor boards Duct smoke detectors have specific limitations SMOKE DETECTORS ARE NOT a substitute for an open area smoke detector NOT a substitute for early warning detection and NOT a replacement for a building regular fire detection system to NFPA 72 and 90A for additional duct smoke detector application information Specifications duct smoke detector shall be a System Model DH200PL or DH200RPL Low Flow Duct Smoke Detector be used with compatible control pan The duct smoke detector shall be UL per UL 268A Standard for Smoke for Duct Applications specifi for use in air handling systems The shall operate in air velocities from to 4000 feet per minute The detec shall be an intelligent photoelectronic It shall be capable of local testing magnetic switch or remote testing from RTS451 or RTS451KEY Remote Test The duct smoke detector housing incorporate an airtight smoke cham in compliance with UL 268A The shall be capable of mounting to rectangular or round ducts without brackets An integral filter system be included to reduce dust and resi effects thereby reducing maintenance servicing Sampling tubes shall be eas installed after the housing is mounted the duct by passing through the duct Terminal connections shall be of strip and clamp method suitable for AWG wiring Specifications Range to 32 VDC Current 24 VDC one communica every 5 seconds with LED blink Current Loads Standby Alarm 0 mA 10 mA Max 0 mA 7.5 mA Max diagram for DH200PL Duct Smoke Detector using a UL listed control panel LISTED CONTROL DETECTOR LOOP DETECTOR LOOP diagram for DH200PL Duct Smoke Detector with optional RA400Z break tab on back of RA400Z when used with DH200PL diagram for DH200PL Duct Smoke Detector with RTS451 RTS451KEY TEST INSTALLED JUMPER RTS451 TERMINAL 3 IS NOT USED DOES NOT HAVE A TERMINAL 6 RTS451KEY TERMINALS 3 AND 6 NOT USED Specifications Requirements using no accessories supply voltage 20 30 VDC 24 VAC 50 60HZ 120VAC 50 60Hz 220 240 VAC 50 60Hz standby current 26 mA 65 mA RMS 44 mA RMS 25 mA RMS alarm current 87 mA 182 mA RMS 52 mA RMS 30 mA RMS response time 3 to 10 sec 3 to 10 sec 3 to 10 sec 3 to 10 sec up time 2 sec 2 sec 2 sec 2 sec Ratings Current Loads at 24 VDC Standby Alarm 0 mA 15 mA Max 0 mA 12 mA Max 0 mA 10 mA Max auxiliary contacts DPDT 10 A 30 VDC 10 A 277 VAC 0.75 power factor 240 VA 249 VAC 0.4 power factor 1 HP 120 VAC 1 HP 240 VAC contact SPST 2.0 A 30 VDC resistive switching current for auxiliary contact be 100 mA DC minimum 5 VDC diagram for DH200RPL Duct Smoke Detector using a UL listed control panel Jumper J1 shunt must be installed for 2 W applications J1 shunt must be removed for power PCB supervision 2 2 External power of 24V AC DC or VAC must be connected in to power all remote horn or accessories JUMPER DETECTOR LOOP JUMPER DETECTOR LOOP diagram for DH200RPL Duct Smoke Detector with optional RA400Z diagram for DH200RPL Duct Smoke with RTS451 RTS451KEY NOT BREAK TAB ON RA400Z 451 RTS451KEY SIGNAL USED USED SIGNAL POWER RTS451 TERMINAL 3 IS NOT RTS451 DOES NOT HAVE TERMINAL 6 FOR RTS451KEY 3 AND 6 ARE NOT USED diagram for DH200RPL Duct Smoke Detector with optional PA400 LISTED CONTROL 7 7 Alarm Signal Aux Power Alarm Signal Aux Power 200 Series Low Flow Specifications Temperature Range to 131 0 to 55 Humidity Range to 93 relative humidity Air velocity 4000 ft min 0.5 20.32 m s 2

Related Files