System Sensor Drop-In Ceiling Speaker and Speaker Strobe for Life Safety Applications

File Preview
File Preview
Click below to download for free

Text Preview

Drop In Ceiling and Speaker for Life Safety Sensor Drop In L Series selectable output speaker and dual voltage evacuation speakers enable faster free installation Strobe shown as installed and close up Complete drop in suspended ceiling speaker and speaker strobe 150 and 177 L Series Platform common speaker and low current strobe Field selectable candela settings on strobe units 15 30 75 95 Automatic selection of 12 or 24 volt operation at 15 and 30 Rotary switch simplifies field selection of speaker voltage 25 and Vrms and power settings 1 and 2 watts Speakers offer high fidelity and high volume sound output Compatible with System Sensor synchronization protocol Electrical compatibility with existing L Series SpectrAlert and Advance products Sensor L Series Drop In Ceiling speaker strobes and strobes install faster than the traditional ceiling or speaker strobe appliances Neutral grill pattern this an excellent option for schools office buildings retail and hospital applications Quickly upgrade your existing Strobe application to a voice system or spec this for your next construction project devices also enable faster installations by providing quick nut connections rotary switches to select voltage and power and seven field selectable candela settings for ceiling strobes low total harmonic distortion of the L Series speaker offers high sound output while still offering high volume sound output for in high ambient noise applications UL Listed 2043 suitable for use in air handling spaces makes installation easy Sized to use with standard drop in ceiling systems 2 ft x 2 ft cm x 61 cm opening Complete turn key solution that eliminates the need for a separate box extension ring and suspended ceiling support bracket Includes seismic tie off or screw attachment points Less time working overhead which reduces installer fatigue Speaker Strobe and Strobe models include a FIRE Decal No more wasting time routing wires in a crowded junction box to Decals available as accessories space for the back of the speaker Listings SPCWL TILE SPCWLA TILE SPSCWA TILE SCWL TILE SCWLA TILE SPCWL TILE Perfect fit the First Time Every Time No more adjusting support to get a tight fit between the appliance and ceiling tile Simplified wiring process saves time and eliminates ground faults Fast learning curve for new installers or summer helpers school retrofits 02 01 2020 Page 1 Speaker Strobe Speaker and Strobe Specifications Specifications Drop In speaker and speaker strobes shall mount to a 2 ft x 2 ft 61 cm x 61 cm suspended ceiling tile opening The back box is within the speaker or speaker strobe assembly The notification appliance circuit and amplifier wiring shall terminate to wires within assembly Also L Series speaker strobes when used with the Sync Module accessory shall be powered from a non coded appliance circuit output and shall operate on a nominal 12 or 24 volts When used with the Sync Module 12 volt rated appliance circuit outputs shall operate between 8.5 and 17.5 volts 24 volt rated notification appliance circuit outputs shall operate 16.5 and 33 volts Indoor L Series products shall operate between 32 and 120 0 and 49 from a regulated DC or full wave unfiltered power supply Speaker strobes shall have field selectable candela settings including 15 30 75 95 115 150 177 speaker shall be a System Sensor L Series model dual voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms should be listed to UL 1480 ULC in Canadian applications and shall be approved for fire protective service The speaker shall have a range of 400 to 4,000 Hz and shall have an operating temperature between 32 and 120 0 and 49 The speaker shall have taps and voltage that are selected by rotary switches Strobe Combination speaker strobe shall be a System Sensor L Series model listed to UL1480 and UL 1971 ULC in Canadian applications and be approved fire protective signaling systems The speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms selected via rotary switch and have a frequency range of 400 to 4,000 Hz The speaker shall have power taps that are selected by rotary switch The strobe shall with the NFPA 72 requirements for visible signaling appliances flashing at 1 Hz over the strobe entire operating voltage range The light shall consist of a xenon flash tube and associated lens reflector system Module module shall be a System Sensor Sync model MDL3 listed to UL 464 ULC in Canadian applications and shall be approved for protective service The module shall synchronize SpectrAlert strobes at 1 Hz The module shall mount to a 411 16 411 16 21 8 inch 11.9 x 11.9 cm x 5.4 cm back box The module shall also control two Class B circuits or one Class A circuit The module shall synchronize zones Daisy chaining two or more synchronization modules together will synchronize all the zones they control The module shall not on a coded power supply Specifications Operating Temperature Range Speaker SCWLA TILE Strobe Speaker Strobe Specifications Voltage speakers Supervisory Voltage speakers Flash Rate Voltage strobes Voltage Range includes fire panels with built in sync Voltage with MDL3 Sync Module Range Speakers to 120 0 to 49 to 93 non condensing in 602 cm in 602 cm in 602 cm in 602 cm in 602 cm in 602 cm 84 mm 84 mm 84 mm Volts or 70.7 Volts nominal VDC flash per second 12 VDC or regulated 24 VDC FWR 1,2 to 17.5 V 12 V nominal or 16 to 33 V 24 V nominal to 17.5 V 12 V nominal or 16.5 to 33 V 24 V nominal to 4,000 Hz3 1 2 watts Full Wave Rectified FWR voltage is a non regulated time varying power source that is used on some power supply and panel outputs Strobe products will operate at 12 V nominal only for 15 and 30 cd 520 Hz 10 square wave tone capable with compatible fire alarm control panel 02 01 2020 Page 2 Current Draw and Sound Output Data Max Strobe Current Draw mA RMS to 17.5 Volts Volts Speaker Sound Output Reverberant 10 ft Anechoic 10 ft W W W W assembly with speaker behind tile protrudes below the tile solution tile rated assembly 2043 neutral hole pattern FIRE label with models Strobe Low current and field selectable for candela range field selectable with to 2W options box 02 01 2020 Page 3 View of Speaker View of Strobe View of Speaker Strobe Ordering Information Mount Number Only UL listed Only ULC listed Only UL listed Only ULC listed Strobe UL listed Strobe ULC listed Kit ALERT pack of 10 Kit FIRE pack of 10 Kit FIRE FEU pack of 10 Kit FUEGO pack of 10 Ceiling Amber Ceiling Blue Ceiling Green Ceiling Red Sensor and SpectrAlert are registered trademarks Sync is a trademark Honeywell International Inc Ohio Avenue St Charles IL 60174 800 SENSOR2 Fax 630

Related Files