System Sensor EOLR-1 Manual

File Preview
File Preview
Click below to download for free

File Data

Name system-sensor-eolr-1-manual-7048561239.pdf
Type PDF
Size 1.03 MB
Downloads

Text Preview

I INSTRUCTIONS 3825 Ohio Avenue St Charles Illinois 60174 FAX 630 377 6495 of Line Supervision Relay Voltage Current Temperature Range Temperature Range Length Ratings to 40 VDC 9 to 35 Vrms for unfiltered full wave rectified supplies mA max to 140 to 60 to 185 to 85 to 93 RH non condensing min 203 mm x 1.65 x 1.22 mm H x 42 mm W x 31 mm D wire nuts piece of double sided tape 11 4 screw VAC 0.5 A max resistive load VDC 3A max resistive load This manual should be left with the owner user this equipment DESCRIPTION EOLR 1 is an epoxy encapsulated single pull single SPST normally open relay that is activated by 9 to VDC This relay can be used as an end of line device in alarm systems e g to supervise power supplies DEFINITIONS RELAY COMMON RELAY NORMALLY OPEN INPUT INPUT ease of installation the EOLR 1 relay may be mounted a variety of ways It can be attached to equipment or an enclosure using the mounting screw or double tape All wiring must conform to applicable local codes and regulations EOLR 1 connections are shown on the label on the of the relay Using the enclosed wire nuts secure the connections appropriate to the application LIMITED WARRANTY Sensor warrants its enclosed relay to be free from defects in materials and under normal use and service for a period of three years from date of System Sensor makes no other express warranty for this relay No agent dealer or employee of the Company has the authority to increase or the obligations or limitations of this Warranty The Company obligation of this shall be limited to the repair or replacement of any part of the relay which is to be defective in materials or workmanship under normal use and service during three year period commencing with the date of manufacture After phoning System toll free number 800 SENSOR2 736 7672 for a Return Authorization number defective units postage prepaid to Honeywell 12220 Rojas Drive Suite 700 El Paso 79936 USA Please include a note describing the malfunction and suspected cause of The Company shall not be obligated to repair or replace units which are found to defective because of damage unreasonable use modifications or alterations occurring the date of manufacture In no case shall the Company be liable for any consequen or incidental damages for breach of this or any other Warranty expressed or implied even if the loss or damage is caused by the Company negligence or fault states do not allow the exclusion or limitation of incidental or consequential dam so the above limitation or exclusion may not apply to you This Warranty gives you legal rights and you may also have other rights which vary from state to state System Sensor 06 10

Related Files