System Sensor FAAST XM 8100

File Preview
File Preview
Click below to download for free

File Data

Name system-sensor-faast-xm-8100-0128935647.pdf
Type PDF
Size 867.92 KB
Downloads

Text Preview

FAAST XM Alarm Aspiration Technology XM aspirating smoke detectors deliver highly Very Early Warning Fire Detection and extensive capabilities to provide maximum control challenging environments Approved for use in Class I Division 2 Groups A B C D Hazardous Locations Detection as precise as 0.00029 ft obscuration Five alarm levels and two sensitivity modes provide flexibility Dual flow detection including both ultrasonic and electronic for pipe and chamber air flow measurement A single device protects up to 8,000 sq ft 743 sq m Advanced detection algorithms reject common nuisance Patented particle separator and field replaceable filter remove from the system PipeIQ software provides intuitive system layout configuration monitoring all in one package Onboard Ethernet interface enables remote monitoring and status updates Ethernet Monitoring and configuration via Modbus TCP protocol Fault indictors exhibit a broad spectrum of events Unique air flow pendulum graph verifies pipe network functionality Particulate graph displays subtle environmental changes for early indications Listings for use in Class I Division 2 Groups A B C and D Hazardous Locations FAAST XM aspirating smoke detector combines source blue LED and infra red laser optical smoke detection advanced algorithms to detect a wide range of res while enhanced immunity to nuisance particulates This FAAST XM to accurately detect incipient re conditions early as 30 to 60 minutes before a re actually starts for Early Fire Detection and Very Early Warning Fire Detection initial system creation the PipeIQ software guides users pipe layout The software also provides intuitive control over con guration and ongoing system monitoring An installed can be monitored through its integral display from a computer to the device remotely through a web browser when detector is connected to a network or by Modbus TCP protocol Ethernet When connected to a mail server FAAST XM can also status updates to appropriate personnel The detector can also alarm levels urgent and minor faults and isolate inputs eight form C relays enable a full detection strategy FAAST XM combines its advanced capabilities with an extensive range of customizable The detector provides ve alarm levels that can be for latching or non latching relays To accommodate c codes or environments alarm delays can be set anywhere 0 to 60 seconds FAAST XM also supports two sensitivity In Acclimate mode the detector automatically adjusts itself current environmental conditions to reduce nuisance alarms Day mode enables technicians to preset alarm thresholds on routine changes in the environment CSIRO approved to AS1603.8 for coverage up to 1,000 square meters A complementary download of PipeIQ is available at VDC monitor must be pulled low for a minimum of 100 ms sec mA 10.0 W 24 VDC mA 11.2W 24VDC All relays active all alarm levels displayed A 30 VDC 0.5 A 125 VAC 0 to 100 38 Factory tested to 122oF 50oC 20 to 140 60 to 95 non condensing sq ft 800 sq m ft min 0 1,219 m min XM Specifications Specifi cations Supply Voltage Reset Time Reset Operating Current Contact Ratings Ratings Temperature Air Temperature Range Rating Area Movement Specifi cations Access Gauge Range Log Network Weight inches 33.7 cm inches 33 cm inches 12.7 cm 1 inch 2.54 cm cable entry top and bottom of unit AWG 2.05 mm to 24 AWG 0.5 mm min ft 80 m ft 137m to 0.827 inches 15 21 Obs ft to 6.25 Obs ft Obs m to 20.5 form C 3 AMP programmable or non latching events stored monitoring E mail address alerts lbs 5.26kg packing material Single Pipe Length Aggregate Length Outside Pipe Diameter 1.050 inches IPS 25 mm Pipe Diameter Sensor Conventional FAAST XM Fire Alarm Aspiration Sensing Technology Information No Replacement Air Filter Assembly Additional accessory information including part numbers can be accessed at systemsensor com faast Card Pipe and Fittings Information Kit Includes Comprehensive Instruction Manual XM User Interface Display User Interface consists of 5 Alarm levels Alert Action 1 Action 2 1 and Fire 2 10 Particulate levels 10 Bi color Flow and Fault graph Ohio Avenue St Charles IL 60174 800 SENSOR2 Fax 630 377 6495 speci cations subject to change without notice Visit systemsensor com current product information including the latest version of this data sheet System Sensor 11 15

Related Files