FAAST XT Pro Alarm Aspiration Technology XT PRO aspirating smoke detectors deliver Very Early Fire Detection with unique pipe identification technology increase the accuracy of smoke detection in large spaces Instantaneous identification of the smoke affected pipe MOS sensor technology employed to identify the inlet drawing Provides Very Early Warning Fire Detection as precise as obscuration Five alarm levels and three sensitivity modes provide flexibility User configurable 3 speed fan allowing for maximum coverage or minimizing on current consumption Ultrasonic flow sensing for each pipe inlet and chamber monitoring for precise system health information A single device covers up to 28,800 square feet Dual source optical detection chamber with enhanced provide high sensitivity with greater immunity to conditions Patented particle separator removes large non fire particulate chamber health and extending the life of the field filter TCP and Serial modbus for easy integration with building systems Easy configuration via USB interface no external power needed Onboard Ethernet interface enables remote monitoring web server and e mail notifications Multilingual LCD user interface allows for detailed device and interaction such as Active faults precise airflow reset of airflow baseline test reset isolate and more Configurable air flow fault thresholds and verification period Convenient wiring compartment Status at a glance provides immediate alarm fault and status Listings FAAST XT Pro aspirating smoke detector combines advanced separation with unique dual source optical smoke detection to provide highly sensitive Very Early Warning Fire while providing enhanced immunity to false alarms This enables FAAST XT Pro to accurately detect incipient re conditions as early as 60 minutes before a re actually starts set for Early Warning and Very Early Warning Fire Detection applications ranging from mission critical to harsh and extreme MOS sensor technology detects the smoke related and provide instantaneous identi cation of the rst inlet smoke into the smoke chamber thus providing even more location of the source of smoke installed FAAST XT Pro device can protect up to 28,800 sq ft sq m in standard coverage type applications and can monitored in several different ways including Serial or TCP Ethernet over a LAN or a direct connection or via FAAST onboard USB When connected to a LAN FAAST XT Pro email can provide email event noti cation to appropriate personnel XT Pro also communicates alarm and noti cations via form C is FAAST XT Pro intuitive design con guration and software The all in one program can be used to create pipe network tailored to meet site speci c requirements con gure FAAST XT Pro device and monitor an installed device including trending and reading of historic reports A complimentary download of PipeIQ is available at XT Pro Specifications Specifi cations Supply Voltage Reset Time Reset Current Current Contact Ratings Specifi cations Temperature Air Temperature Range Range Rating Area Movement Specifi cations Access Gauge Single Pipe Length Pipe Length Pipe Diameter Pipe Diameter Specifi cations Log Data Log VDC monitor must be pulled low for a minimum of 100 ms sec High 565mA 11.2W Fan Med 440mA 8.2W Fan Low 320mA 5.3W High 593mA 11.85W Fan Med 468mA 8.85W Fan Low 348mA 6W A 30 VDC 0.5 A 125 VAC 8 form C 3 AMP programmable latching or non latching 0 to 100 38 Factory Tested to 133 55 20 to 140 60 to 95 non condensing Obs ft to 6.25 Obs ft 0.00095 Obs m to 20.5 Obs m sq ft 2,676 sq m ft min 0 1,219 m min in 338 mm in 333 mm in 191 mm 1 inch 2.54 cm cable entry holes on top bottom and back of the unit AWG 2.05 mm max to 24 AWG 0.5 mm min ft 123 m other three pipes disabled ft 320 m all designs must be veri ed within PipeIQ software inches IPS 25 mm to 0.827 inches 15 21 mm form C 3 AMP programmable latching or non latching Log Specifi cations Network Services events stored gurable sampling period 1 to 1 day custom user entries monitoring 6 email alerts TCP and Modbus SMTP HTTP MODBUS AutoIP NetBIOS NS Serial MDI X or Serial RS 485 recipients selectable cations Con guration View Logs guration Specifi cations or Ethernet or RS 485 XT User Interface Display User Interface consists of 5 Alarm levels Alert Action 1 2 Fire 1 and Fire 2 4 Pipe Alarm Indicators 10 Particulate 10 Air ow Indicators 4 Fault Indicators LCD Information No Additional accessory information including part numbers can be accessed at systemsensor com faast Sensor Conventional FAAST Fire Alarm Aspiration Sensing Technology Pipe and Fittings Ohio Avenue St Charles IL 60174 800 SENSOR2 Fax 630 377 6495 speci cations subject to change without notice Visit systemsensor com current product information including the latest version of this data sheet System Sensor 10 16

Related Files