Figure 5 Installing Filtrex detector into base AND MAINTENANCE INSTRUCTIONS a clogged filter was the cause of the trouble condition detector operation should resume automatically five minutes If the trouble condition persists the must be returned for repair or replacement Filtrex Into Base Align the detector at a right angle to the base with the wires and connector adjacent to the connector re as shown in Figure 5 Plug the wired connector into the receptacle Rotate the detector into the base making sure detector base keyed fit is lined up Turn the detector clock until it snaps into place will only operate with B501B FTX Mounting Base Limitations of Property Protection Smoke Detectors smoke detector is designed to activate and initiate emergency ac but will do so only when it is used in conjunction with an authorized alarm system This detector must be installed in accordance with standard 72 detectors will not work without power AC or DC powered detectors will not work if the power supply is cut off detectors will not sense fires which start where smoke does not the detectors Smoldering fires typically do not generate a lot of which is needed to drive the smoke up to the ceiling where the detector is usually located For this reason there may be large de in detecting a smoldering fire with either an ionization type detector a photoelectric type detector Either one of them may alarm only after has initiated which will generate the heat needed to drive the to the ceiling from fires in chimneys in walls on roofs or on the other side of a door s may not reach the smoke detector and alarm it A detector detect a fire developing on another level of a building quickly or at For these reasons detectors shall be located on every level and in bedroom within a building detectors have sensing limitations too Ionization detectors and detectors are required to pass fire tests of the flaming and type This is to ensure that both can detect a wide range of of fires Ionization detectors offer a broad range of fire sensing capa but they are somewhat better at detecting fast flaming fires than smoldering fires Photoelectric detectors sense smoldering fires better flaming fires which have little if any visible smoke Because fires de in different ways and are often unpredictable in their growth nei type of detector is always best and a given detector may not always early warning of a specific type of fire general detectors cannot be expected to provide warnings for fires re from inadequate fire protection practices violent explosions es gases which ignite improper storage of flammable liquids like solvents which ignite other similar safety hazards arson smok in bed children playing with matches or lighters etc Smoke detectors in high air velocity conditions may have a delay in alarm due to dilu of smoke densities created by frequent and rapid air exchanges Addi high air velocity environments may create increased dust demanding more frequent maintenance keep your equipment in excellent working order ongoing maintenance required per the manufacturer recommendations and UL and NFPA At a minimum the requirements of Chapter 7 of NFPA 72 the Fire Alarm Code shall be followed A preventative maintenance should be arranged through the local manufacturer represen Though smoke detectors are designed for long life they may fail at time Any smoke detector fire alarm equipment or any component of system which fails shall be repaired or replaced as soon as possible Limited Warranty Sensor warrants its enclosed smoke detector to be free from de in materials and workmanship under normal use and service for a of three years from date of manufacture System Sensor makes no express warranty for this smoke detector No agent representative or employee of the Company has the authority to increase or alter obligations or limitations of this Warranty The Company obligation this Warranty shall be limited to the repair or replacement of any part of smoke detector which is found to be defective in materials or work under normal use and service during the three year period com with the date of manufacture After phoning System Sensor toll number 800 SENSOR2 736 7672 for a Return Authorization number defective units postage prepaid to System Sensor Repair Depart RA 3825 Ohio Avenue St Charles IL 60174 Please a note describing the malfunction and suspected cause of failure Company shall not be obligated to repair or replace units which are to be defective because of damage unreasonable use modifica or alterations occurring after the date of manufacture In no case the Company be liable for any consequential or incidental damages breach of this or any other Warranty expressed or implied whatsoever if the loss or damage is caused by the Company negligence or fault states do not allow the exclusion or limitation of incidental or conse damages so the above limitation or exclusion may not apply to This Warranty gives you specific legal rights and you may also have rights which vary from state to state Statement device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interfer and 2 this device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio commu However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interfer to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help SENSOR Division of Pittway 3825 Ohio Avenue St Charles Illinois 60174 FAX 630 377 6495 Filtrex Intelligent Smoke Detector Voltage Range Current Power Supply Voltage Power Supply Current Humidity Range Temperature Range Air Velocity Base to 32 VDC m A 24 VDC without communication m A 24 VDC one communication every 5 sec with LED enabled to 30 VDC filtered Ripple voltage may not drop below 15 volts mA max mA max to 93 Relative Humidity noncondensing to 50 cid 176 C 32 cid 176 to 122 cid 176 F ft min particulate down to 25 microns inches 43 mm inches 155 mm installed in B501B FTX inches 102 mm installed in B524FTXE oz 207 g compatible with 200 and 500 series products protocol B501B FTX U S B524FTXE Europe Installing detector must be installed in compliance with the panel system installation manual The installation meet the requirements of the Authority Having Juris AHJ Detectors offer maximum performance installed in compliance with the National Fire Pro Association NFPA see NFPA 72 Description Sensor Filtrex Smoke Detector uses a small air in fan and a high density replaceable filter Air and are drawn into a photoelectric sensing chamber airborne particulate and water mist are removed The detector transmits an analog represen of smoke density over a communication line to a panel Rotary decade switches are provided for set the sensor address Two LEDs on the sensor are con by the panel to indicate sensor status smoke detector is intended for use in normal en conditions where dust and other airborne are present at elevated levels These elevated tend to cause false alarms and high maintenance standard detectors Filtrex provides a protective enclo for a photoelectric smoke detector chamber and al smoke detection in areas that tended

Related Files