System Sensor Multi-Voltage Relays

File Preview
File Preview
Click below to download for free

File Data

Name system-sensor-multi-voltage-relays-0647129835.pdf
Type PDF
Size 793.69 KB
Downloads

Text Preview

Multi Voltage Relays Sensor multi voltage conventional relays used for high current switching applications such fan and damper assembly control door control handling unit controls and other types of system operation LEDs and flexible installation and robust design field installations relays with terminal strip field wiring connections track and hardware for R 10T 20T and R 14T 24T front cover on steel enclosure for R 10E R 20E and R which mount inside the enclosure viewing hole on top of the steel enclosure cover pair of wires for redundant power input on PR 3 strip field wiring connections mounting track and Listings R 10T R 20T R 14T and the R 24T models are multi relays with terminal strip field wiring connections mounting and hardware The R 10T is a single FORM SPDT relay with red activation LED and the R 14T is a four gang 1 FORM SPDT with four red activation LEDs The R 20T is a single 2 FORM relay with a red activation LED and the R 24T is a four gang 2 DPDT relay with four red activation LEDs R 10E R 20E and R 14E R 24E are similar to the T series mount relays but they are mounted into a steel enclosure The has a removable front cover that provides easy access and LED viewing hole on the top of the cover are epoxy encapsulated multi voltage relays They single pole double throw relays that use a red LED as a visible of relay coil energization PR is to PR except it has an extra pair of wires for redundant input EOLR 1 is an epoxy encapsulated single pole single throw open relay that can be used as an end of line device in fire systems e g to supervise power supplies Conventional Relay Specifications R 10T R 14T R 20T R 24T Voltage Current R 10E R 14E R 20E R 24E Voltage Current Temperature Range Ratings Temperature Range Ratings 35 VDC 18 35 VAC 115 VAC 230 VAC mA DC max 24 VDC 24 VAC 115 VAC VAC R 10T R 14T mA DC max 24 VDC 24 VAC 115 VAC VAC R 20T R 24T to 158 to 70 93 non condensing 2.5 3.35 1.2 10 3.35 1.2 VDC 7 A with L R 5 mS VAC 10 A VAC 1 6 HP VAC 7 A 35 VDC 18 35 VAC 115 VAC 230 VAC mA DC max 24 VDC 24 VAC 115 VAC VAC R 10E R 14E mA DC max 24 VDC 24 VAC 115 VAC VAC R 20E R 24E to 158 to 70 93 non condensing 5.1 3.75 2.5 11 5.3 2.5 VDC 7 A with L R 5 mS VAC 10 A VAC 1 6 HP VAC 7 A PR 1 Voltage Current Temperature Range Length Ratings 35 VDC 18 35 VAC 120 VAC mA DC max 24 VDC 24 VAC 120 VAC to 158 to 70 93 RH minimum 2.01 1.42 VDC 7 A with L R 5 mS VAC 7 A max 0.35 PF VAC 10 A resistive VDC 10 A resistive PR 2 PR 3 Voltage Current Temperature Range Length Ratings EOLR 1 Voltage Current Temperature Range Length Ratings to 40 VDC mA DC max to 158 to 70 93 RH minimum 1.65 1.22 VAC 10 A max resistive load VAC 7 A max 0.35 PF VAC 10 A max resistive load VDC 10 A max resistive load to 40 VDC mA DC max to 140 to 60 93 RH minimum VAC 0.5 A max resistive load VDC 3 A max resistive load R 20E Enclosure R 24E Enclosure Ohio Avenue St Charles IL 60174 800 SENSOR2 Fax 630 377 6495 System Sensor specifications subject to change without notice Visit systemsensor com for product information including the latest version of this data sheet 3 07 1782

Related Files