System Sensor PDRP-2001 C E Data Sheet WFDS873

File Preview
File Preview
Click below to download for free

File Data

Name system-sensor-pdrp-2001-c-e-data-sheet-wfds873-9365184702.pdf
Type PDF
Size 793.06 KB
Downloads

Text Preview

PDRP 2001 PDRP 2001C PDRP 2001E Deluge Control Panels re detection signaling and protection for industrial and institutional buildings water based releasing Designed for sprinkler standards NFPA 13 15 and 16 Allows connection to 220 240 VAC Dual hazard operation Adjustable water flow discharge timer and two soak timers Cross zone double interlock capability 6 programmable Style B Class B IDCs Initiating Device Circuits System Sensor i Series detector compatibility 4 programmable Style Y Class B output circuits special power Compatible with System Sensor synchronization protocol 3 programmable Form C relays 7.0 amps total 24 VDC output current Resettable and non resettable output power Built in programmer 80 character LCD display backlit Real time clock calendar with daylight saving time control History log with 256 event storage Piezo sounder for alarm trouble and supervisory Low AC voltage sense Listings PDRP 2001 PDRP 2001C and PDRP 2001E re alarm control FACPs are compatible with the System Sensor i Series smoke detectors that transmit signals to the FACP to important status conditions such as low temperature 45 or required maintenance This control panel is compatible conventional input devices such as water ow devices tamper 2 wire smoke detectors 4 wire smoke detectors pull and other normally open contact devices The PDRP 2001 and PDRP 2001E panels supervise wiring AC voltage charge and battery level installed water ow detector compatible smoke detector or normally open re alarm initiating device will activate audible visual signaling devices illuminate an indicator display alarm on the panel LCD sound the piezo sounder at the FACP the FACP alarm relay and operate an optional module used notify a remote station or initiate an auxiliary control function outputs are programmable as noti cation appliance circuits or releasing circuits Three programmable Form C relays programmed for alarm trouble and supervisory and 24 VDC application resettable and non resettable power outputs are included on the main circuit board otherwise speci ed the information in this data sheet applies both the 110 120 VAC and 220 240 VAC versions of the panels and PDRP 2001 E System Specifications Specifi cations Dimensions Dimensions Ring TR CE Dimensions and Humidity 50.80 cm H 22.50 57.15 cm W 8.50 21.59 cm D 48.92 cm H 16.82 42.73 cm W 0.72 1.82 cm D 48.26 cm H 16.65 42.29 cm W 5.25 13.34 cm D 55.88 cm H 19.65 49.91 cm W system meets NFPA requirements for operation at 32 to 120 0 to 49 and at a relative humidity 93 2 RH at 90 3 32 2 However the useful life of the system standby batteries and the electronic may be adversely a ected by extreme temperature ranges and humidity Therefore it is recommended that system and its peripherals be installed in an environment with a normal room temperature of 60 to 80 15 to 27 PDRP 2001E complies with the following NFPA 72 Fire Alarm Systems requirements NFPA 13 Installation of Sprinkler Systems NFPA 15 Water Spray Fixed Systems NFPA 16 Deluge Foam Water Sprinkler and Foam Water Spray Systems NFPA 72 National Fire Alarm Code for Local Fire Alarm Systems and Remote Station Fire Alarm Systems requires an Remote Station Output Module Custom English labels per point may be manually entered or selected from an internal library le Three programmable Form C relay outputs Pre programmed and custom application templates Continuous re protection during online programming at the front panel Program Check automatically catches common errors not linked to any zone or input point Interface Integral 80 character LCD display with backlighting Real time clock calendar with automatic daylight saving time adjustments ANN BUS for connection to remote annunciators Audible or silent walk test capabilities Piezo sounder for alarm trouble and supervisory Indicators Fire Alarm Red Supervisory Yellow Trouble Yellow AC Power Green Alarm Silenced Yellow Discharge Red Buttons Acknowledge Step Alarm Silence System Reset Lamp Test Drill PDRP 2001 E version Acknowledge Step Signal Silence Reset Lamp Test Alarm Signal PDRP 2001C version FLPS 7 Power Supply 120 VAC 50 60 Hz 2.3 amps FLPS 7 Power Supply 240 VAC 50 Hz 1.15 amps Wire size minimum 14 AWG 2.0 mm2 with 600 V insulation Supervised nonpower limited Battery sealed lead acid only J12 Maximum Charging Circuit normal at charge 27.6 VDC 1.4 amp supervised nonpower limited Maximum Charger Capacity 26 amp hour battery Two 18 amp hour batteries can be housed in the FACP cabinet Larger require a separate battery box such as the BB 26 Minimum Battery Size 7 amp hour Alarm Zones 1 on TB4 Alarm Zone 6 on TB6 Supervised and power limited circuitry Style B Class B wiring with Style D Class A option Normal Operating Voltage Nominal 20 VDC Alarm Current 15 mA minimum Short Circuit Current 40 mA max Maximum Loop Resistance 100 Ohms End of Line Resistor 4.7 KOhms watt Part 71252 Standby Current 4 mA programmable for silence inhibit auto silence PDRP 2001 E only strobe synchronization selective silence mute temporal or steady signal silenceable or non silenceable release stage sounder Four Output Circuits Style Y Class B or Style Z Class A with optional converter module Special application power Supervised and power limited circuitry Normal Operating Voltage Nominal 24 VDC Maximum Signaling Current 7.0 amps 3.0 amps maximum per NAC End of Line Resistor 4.7 KOhms watt Part 71252 Max Wiring Voltage Drop 2 VDC Capacity Annunciators Standards and Software and Indicators Specifi cations Power TB1 Device Circuits TB4 TB6 cation Appliance and Circuit s TB5 and C Relays Programmable TB8 Trouble Input J6 Application Resettable TB9 Application Resettable Nonresettable Power TB9 Relay 1 factory default programmed as Alarm Relay Relay 2 factory default programmed as fail safe Trouble Relay Relay 3 factory default programmed as Supervisory Relay Relay Contact Ratings 2 amps 30 VDC resistive 2 amps 30 VAC resistive Auxiliary Trouble Input is an open collector circuit that can be used to monitor external devices for trouble conditions It be connected to the trouble bus of a peripheral such as a power supply that is compatible with open collector circuits Operating Voltage Nominal 24 VDC Maximum Available Current 500 mA appropriate for powering 4 wire smoke detectors Total current for resettable power non resettable power and Output Circuits must not exceed 7.0 amps Power Limited Circuitry Operating Voltage Nominal 24 VDC Maximum Available Current 500 mA Total current for resettable power nonresettable power and Output Circuits must not exceed 7.0 amps Power Limited Circuitry Jumper selectable by JP31 for resettable or non resettable power Optional CAC 5X Class A Converter Module for Outputs and IDCs Optional 4XTM Municipal Box Transmitter Module Optional Digital Alarm Communicators Information No zone 24 volt deluge preaction control panel includes backbox power supply technical manual and a fram

Related Files