System Sensor RRS-MOD Manual

File Preview
File Preview
Click below to download for free

File Data

Name system-sensor-rrs-mod-manual-0596138274.pdf
Type PDF
Size 848.76 KB
Downloads

Text Preview

insTaLLaTion and mainTenanCe insTruCTions reversing relay synchronization module Ohio Avenue St Charles Illinois 60174 FAX 630 377 6495 In an alarm condition a wiring fault state may also register at the panel the RRS MOD is used Voltage Range Operating Current Contacts Temperature Range Humidity Range connections to 35 VDC at 35 VDC to 131 F 0 to 55 C to 93 non condensing x 21 x 1 AWG stranded tinned 16 long desCriPTion RRS MOD polarity reversing relay synchronization module is intended use with 2 wire and 4 wire i3 series detectors equipped with a built in models 2WTA B 4WTA B 4WTAR B and 4WITAR B It is designed allow all the detectors in the same loop to sound when one of the detectors into alarm and to synchronize their audible output The RRS MOD also the silencing of the detector sounders from the alarm control panel RRS MOD may be used with an alarm zone that provides coded output for and continuous output for burglary By default the RRS MOD switch is to Therefore the RRS MOD will only trigger when the alarm output coded In this manner smoke detectors will only sound from the result of a and not from a burglary alarm In this mode the detectors will provide a coded output The RRS MOD contains a relay that is meant for applications per UL 864 RRS MOD can also be set to only trigger on continuous alarm zone sig by selecting the switch to In this mode the detectors will provide a coded output This manual shall be left with the owner user of this equipment in a dry indoor location Choose a mounting location in the control within reach of the provided wire leads Use a water isopropyl alcohol 50 50 to clean the mounting surface Allow surface to dry and re paper backing from the Velcro and catch Stick the Velcro in the panel the catch on the back of the module then mount the module inside the panel Route terminals to the appropriate terminals as noted below calculating total current draw of the control panel remember to add consumption 25mA for the polarity reversal relay module RRS IMPORTANT If the fire alarm output signal is coded set the switch on RRS MOD to If the fire alarm output signal is continuous set the to All polarities must be observed Connect the RRS MOD module trigger wire to the fire alarm output terminals A Alarm Bell output Figures 1 and 2 the purple wire to the Alarm or Bell output Alarm relay normally open contact Figures 3 and 4 Connect one end of the alarm relay contact output to positive or detector power fire alarm output Connect the purple wire to the other end of the alarm relay output Connect the red and black wires to the panel auxiliary or detector power to positive black to negative 2 wire models 4 wire models 2 wire models 4 wire models Connect the yellow and orange wires to the panel initiating circuit yel to positive orange to negative Connect the yellow and orange wires to the panel detector power circuit to positive orange to negative Connect the brown and white wires to the smoke detector power supply brown to positive white to negative Connect the brown and white wires to the smoke detector power circuit to positive white to negative using the RRS MOD with model do not mix the 2WTA B with model smoke detectors and dry closure devices including me heat detectors manual pull and waterflow switches Such can cause a direct short on the power terminals damaging the panel internal circuitry and or devices connected to the initi device circuit IN OUT IN OUT RA RA Please refer to Figures 5 and 6 for Ademco Vista panels and Figures 7 and 8 for DSC Power 832 panels 1 2 Wire sYsTem Triggered From aLarm BeLL ouTPuT IN OUT IN OUT RA RA 2 4 Wire sYsTem Triggered From aLarm BeLL ouTPuT IN OUT IN OUT N O C IN OUT IN OUT N O C 3 2 Wire sYsTem Triggered From aLarm reLaY ConTaCT LISTED signal alarm state POWER LISTED signal alarm state POWER LISTED Contact POWER IN OUT IN OUT RA RA RELAY ENERGIZED IN OUT IN OUT RA RA LISTED Contact POWER 4 4 Wire sYsTem Triggered From aLarm reLaY ConTaCT RELAY ENERGIZED IN OUT IN OUT N O C IN OUT IN OUT N O C diagrams WiTh ademCo VisTa PaneLs connection diagrams enclosed show how to connect the 2WTA B model smoke detector to the Vista panels using the System Sensor polarity reversal relay RRS MOD Please make sure that the smoke detectors are connected properly to the zones specified in the wiring diagrams for proper operation of the detectors 5 ConneCTing 2WTa B smoke deTeCTors To ademCo ConTroLs using rrs mod moduLe Triggered From BeLL aLarm CirCuiT SENSOR REVERSING RRS MOD INSIDE CONTROL ENCLOSURE LISTED signal in alarm state WIRE POWER IN OUT IN OUT N O C information OHMS The supervisory feature for the bell cir must be turned off See applicable manual for procedure Configuration Set switch on RRS MOD to IN OUT IN OUT RA C WATT SENSOR SMOKE TO 16 DETECTORS ZONE 1 2 WATT RESISTOR NEEDED FOR PANEL TO RESET 6 ConneCTing 2WTa B smoke deTeCTors To ademCo ConTroLs using rrs mod moduLe Triggered From auxiLiarY reLaY REQUIRED ON 5110XM 5100XM JUMPER W3 INTACT SENSOR REVERSING MODULE RRS MOD INSIDE CONTROL ENCLOSURE LISTED WIRE IN OUT IN OUT RA RA POWER WATT SENSOR SMOKE TO 16 DETECTORS ZONE

Related Files