System Sensor RTC100 Manual

File Preview
File Preview
Click below to download for free

File Data

Name system-sensor-rtc100-manual-7638490215.pdf
Type PDF
Size 631.62 KB
Downloads

Text Preview

INSTALLATION AND MAINTENANCE INSTRUCTIONS Remote Test Coil Kit for use with the Profile B114LP and B114LPBT Bases Ohio Avenue St Charles Illinois 60174 FAX 630 377 6495 6.1 diameter flanged base 1.66 high Power Requirements LED 2.8 32 VDC 10 mA max Coil 15.5 32 VDC 95 mA max Current 105 mA max Switch 10 VA 32 VDC Switch 10 VA 32 VDC Response Time 40 seconds max Temperature Range to 60 14 to 140 10 to 95 RH noncondensing This manual should be left with the owner user this equipment 1 Description System Sensor Model RTC100 Remote Test Coil Kit al for the remote testing of duct smoke detectors using B114LP 120 VAC or B114LPBT 24 VAC DC bases installed in inconvenient or difficult to reach loca Model RTC100 can be installed in almost any conve location and can be attached to a standard 2 4 box National Fire Protection Association has published and practices for the installation and use of this As a result System Sensor recommends that the be familiar with these standards and practices codes and any special requirements of the authority jurisdiction Contents RTS451 Remote Test Station Test Coil Replacement Ring Screw Pack 2 mounting Assembly screws Jumper with spade lugs M02 04 Test Magnet of the Model RTC100 consists of attaching the station to the mounting surface mounting the test coil ring on the detector and routing the necessary between them This installation procedure assumes the associated detector base is already installed and for operation MAGNET 1 I56 1493 01 Ring Replacement 1 Remove the decorative ring from the B114LP base by rotating it in either direction to the hooks Separate the ring from the base 2 Position the Test Coil Replacement Ring Assembly on base as shown in Figure 2 Be sure to position the coil directly over the 4 Position Terminal Block the coil may not activate the switch during test 3 Route the the Test Coil Replacement Ring Assembly through the slot in the base as indicated in 2 4 Rotate the ring in either direction until it snaps in Dress all wiring as needed Wiring 1 Route four wires from the B114LP B114LPBT to the station mounting location Be sure to comply all applicable electrical codes when installing wiring This includes selecting the proper wire and routing through conduit if necessary 2 Connect the wiring to the B114LP B114LPBT Base and Test Station as shown in Figure 3 Test Station Mounting Attach the test station to a standard 2 4 electrical using the screws supplied with the box the painted side of the test magnet on the RTS451 Station on either the left or right side of the LED as in Figure 1 The LED should light within 40 seconds that the detector being is latched in alarm the detector by inserting a narrow bladed pocket or other similar tool into the RESET hole the front of the test station Gently press until the LED off 2 Ring Replacement 3 RTC100 Wiring Diagram COIL Limited Warranty Sensor warrants its enclosed smoke detector to be free from de in materials and workmanship under normal use and service for a of three years from date of manufacture System Sensor makes no express warranty for this smoke detector No agent representative or employee of the Company has the authority to increase or alter obligations or limitations of this Warranty The Company obligation this Warranty shall be limited to the repair or replacement of any part the smoke detector which is found to be defective in materials or work under normal use and service during the three year period com with the date of manufacture After phoning System Sensor toll number 800 SENSOR2 736 7672 for a Return Authorization number defective units postage prepaid to System Sensor Returns Depart RA 3825 Ohio Avenue St Charles IL 60174 Please a note describing the malfunction and suspected cause of failure Company shall not be obligated to repair or replace units which are to be defective because of damage unreasonable use modifica or alterations occurring after the date of manufacture In no case the Company be liable for any consequential or incidental damages breach of this or any other Warranty expressed or implied whatsoever if the loss or damage is caused by the Company negligence or fault states do not allow the exclusion or limitation of incidental or con damages so the above limitation or exclusion may not apply to This Warranty gives you specific legal rights and you may also have rights which vary from state to state 2 I56 1493 01 System Sensor 2003

Related Files