System Sensor SA Horns, Strobes and Horn Strobes Manual
File Preview
Click below to download for free
Click below to download for free
File Data
Name | system-sensor-sa-horns-strobes-and-horn-strobes-manual-3176948205.pdf |
---|---|
Type | |
Size | 1.68 MB |
Downloads |
Text Preview
INSTALLATION AND MAINTENANCE INSTRUCTIONS Output Strobes Horns and Horn Strobes Ohio Avenue St Charles Illinois 60174 FAX 630 377 6495 use with the following models P2R P2RH P2RK P2RHK P2W P2WK P2WH P2WHK P4R P4RH P4RK P4W P4WK P4WHK P SR SRH SRK SRHK SW SWK SWH SWHK PC2R PC2RH PC2RK PC2RHK PC2W PC2WK PC2WH PC2WHK PC4R PC4RH PC4W PC4WK PC4WHK SCR SCRH SCRK SCRHK SCW SCWK SCWH SC SCW CLR ALERT HR HRK HW SR P SW P SRH P SWH P P2R P P2W P P2WH P P4R P P4W P SCW P PC2R P PC2W P PC2WH P SRK P SRHK P P2RK P P2RHK P SWK P P2WK P P2WHK P SR SP P2R SP PC2W SP SRK R SWK R SRHK R SWHK R P2RK R P2WK R P2RHK R P2WHK R SBHK SBK R Refer to your panel documentation or models listed for use with specific panels All R models are specifically designed for use with the WTP Series of Weatherproof plates When replacing outdoor units device and back box must be replaced Models SBHK SBK R are UL listed for General Signaling SPECIFICATIONS Temperature Products Series Products Series Range Flash Rate Voltage Voltage Range includes fire alarm panels with built in sync Voltage with MDL3 Sync Module terminal wire gauge to 120 0 to 49 to 151 to 93 Non condensing NEMA 4X requirements flash per second 12VDC FWR or regulated 24DC FWR to 17.5V 12V nominal or 16 to 33V 24V nominal to 17.5V 12V nominal or 16.5 to 33V 24V nominal to 18 AWG Strobes will operate at 12 V nominal for 15 15 75 candela settings only Switching between ranges is automatic FOR PRODUCTS AND ACCESSORIES PRODUCTS and Horn Strobes including lens Red Weatherproof Back Box White Weatherproof Back Box Red Surface Mount Box White Surface Mount Box BOX OPTIONS mm mm 64 mm PRODUCTS and Horn Strobes lens Red Weatherproof Back Box mm mm mm mm mm 33 mm SA WBBCW White Weatherproof Back Box mm Red Surface Mount Box mm 130 mm 51 mm SBBCW White Surface Mount Box mm mm mm mm 109 mm SA WBB SA WBBW SA WBBC and SA WBBCW dimensions not include the two mounting tabs Indoor Products Indoor Products Series Products 4 11 2 Single Gang Double Gang 4 Octagon wall SBBCR W ceiling 4 11 2 Double Gang 4 Octagon wall SA WBBC CW ceiling This manual shall be left with the owner user of this equipment DESCRIPTION SpectrAlert Advance series of notification appliances offers a wide range horns strobes and horn strobes for wall and ceiling applications indoors outdoors They are designed to be used on 12 or 24 volt DC or FWR wave rectified systems These products are electrically backward compat with the previous generation of SpectrAlert notification appliances Horn products are available in two versions The 2 wire products fit systems a single NAC controls both horn and strobe The 4 wire products are in for systems which have separate wiring circuits for the horn and strobe SpectrAlert Advance products are suitable for use in synchronized systems System Sensor MDL3 module may be used to provide synchronization Series products are designed to be used over a wider range of temperatures are suitable for use in wet environments with outdoor backbox supplied product and ceiling products may be used interchangeably wall products be used on the ceiling and ceiling products may be used on the wall ALARM SYSTEM CONSIDERATIONS National Fire Alarm Code NFPA 72 requires that all horns used for evacuation produce temporal coded signals Signals other than those for evacuation purposes do not have to produce the temporal coded sig System Sensor recommends spacing notification appliances in compli with NFPA 72 DESIGN AND WIRING system designer must make sure that the total current drawn by the de on the loop does not exceed the current capability of the panel supply that the last device on the circuit is operated within its rated voltage The draw information for making these calculations can be found in the within this manual For convenience and accuracy use the voltage drop on the System Sensor website www systemsensor com calculating the voltage available to the last device it is necessary to the voltage drop due to the resistance of the wire The thicker the the smaller the voltage drop Wire resistance tables can be obtained electrical handbooks Note that if Class A wiring is installed the wire may be up to twice as long as it would be for circuits that are not tolerant The total number of strobes on a single NAC must not exceed 40 for volt applications or 12 for 12 volt applications Loop resistance on a single should not exceed 120 ohms for 24 volt and 30 ohms for 12 volt systems 1 3 list the minimum light output requirements per UL1971 2 LIGHT OUTPUT DISPERSION of SELECTION the rotary switch on the back of the product to the desired setting For and 4 wire horn strobe products the current draw for each setting is in Table 3 For 2 wire horn strobe products P2 series current draws listed in Tables 4 and 5 The sound output measurement for each horn is shown in Table 6 3 HORN CURRENT DRAW mA FOR H P4 PC4 SERIES 1 STROBE CURRENT DRAW mA FOR S SC P4 PC4 SERIES Volts Volts Candela Range Candela Range 2 CANDELA DERATING Candela rating at Series Outdoor Applications Only not use below 32 Pattern Out Medium Volts Volts In positions 7 8 and 9 temporal coding must be provided by the NAC the NAC voltage is held constant the horn output will remain constantly on 7 8 and 9 are not available on 2 wire horn strobe products SELECTION the slide switch on the rear of the product to the desired candela set in the small window on the front of the unit All products meet the light profiles specified in the appropriate UL Standards See Figures 1 3 Table 1 to determine the current draw for each candela setting For K products used outdoors at low temperatures listed candela ratings must reduced in accordance with Table 2 SpectrAlert products set at 15 and 15 75 candela automatically work either 12V or 24V power supplies The products are not listed for 12V op voltages when set to any other candela settings For 4 Wire products current draw may be determined by adding current draw for the specific selection and the current draw for the specific horn selection use 1 and Table 3 1 LIGHT OUTPUT VERTICAL DISPERSION CEILING TO WALLS FLOOR of is generated text for 3 LIGHT OUTPUT VERTICAL DISPERSION WALL TO FLOOR 45 the right 45 the right of of degree is permitted 4 2 WIRE HORN STROBE CURRENT DRAW mA FOR P2 AND PC2 STANDARD CANDELA SERIES Volts cd cd cd Volts cd cd 5 2 WIRE HORN STROBE CURRENT DRAW mA FOR P2 AND PC2 HIGH CANDELA RANGE SERIES Volts Volts DC cd cd cd cd