System Sensor SAA Outdoor Ceiling Horns Strobes and Strobes (AVDS11402)

File Preview
File Preview
Click below to download for free

Text Preview

Outdoor Selectable Strobes and Strobes for Applications Advance outdoor audible visible products rich with features that cut installation times and profits Weatherproof NEMA 4X IP56 rated Listed to UL 1638 strobe and UL 464 horn Compatible with System Sensor synchronization protocol and SpectrAlert products Field selectable candela settings 15 15 75 30 75 95 110 115 150 177 and 185 candela Automatic selection of 12 or 24 volt operation at 15 and Rotary switch for horn tone and three volume selections Horn rated at 88 dBA at 16 volts Rated from to 151 Universal mounting plate with an onboard shorting spring that wiring continuity before devices are installed Plug in design with minimal intrusion into the back box Tamper resistant construction Listed for ceiling or wall mounting Listings chimes horn strobes horns outdoor and alert strobes outdoor strobes horn strobes strobes horns chimes Advance offers the broadest line of outdoor horns and horn strobes in the industry With white or red plastic wall or ceiling mounting options and plain or FIRE printed SpectrAlert Advance can meet virtually any application including indoor outdoor wet and dry applications in from to 151 the entire SpectrAlert Advance line outdoor strobes and horn for ceiling applications include a variety of features that application flexibility and simplify installation First field settings including candela automatic selection of 12 or operation horn tones and three volume options enable to easily adapt devices to meet requirements SpectrAlert Advance devices use a universal mounting plate both wall and ceiling applications This mounting plate includes onboard shorting spring that ensures wiring continuity before are installed so installers can verify proper wiring without the devices and exposing them to potential construction Once the plates are mounted all SpectrAlert Advance utilize a plug in design with a single captured screw to installation and virtually eliminate costly ground faults devices ship with weatherproof plastic back boxes metal boxes are available separately that accommodate in and wiring for daisy chaining devices Plastic back boxes feature side flanges and improved resistance to saltwater Plastic and metal weatherproof back boxes come with top and bottom conduit entries and knock outs at the Three screw in NPT plugs with O ring gaskets for a watertight is included with each back box Advance Outdoor Strobe and Horn Strobe Specifications Specifications Advance outdoor horns strobes and horn strobes shall mount to a weatherproof back box A universal mounting plate shall used for mounting ceiling and wall products The notification appliance circuit wiring shall terminate at the universal mounting plate SpectrAlert Advance products when used with the Sync Module accessory shall be powered from a non coded notification circuit output and shall operate on a nominal 12 or 24 volts When used with the Sync Module 12 volt rated notification circuit outputs shall operate between 8.5 and 17.5 volts 24 volt rated notification appliance circuit outputs shall operate between and 33 volts Outdoor SpectrAlert Advance products shall operate between and 151 degrees Fahrenheit from a regulated DC or full rectified unfiltered power supply Strobes and horn strobes shall have field selectable candela settings including 15 15 75 30 75 95 115 135 150 177 and 185 strobe shall be a System Sensor SpectrAlert Advance Outdoor Model listed to UL 1638 and shall be approved for fire protective The strobe shall be wired as a primary signaling notification appliance and comply with the Americans with Disabilities Act for visible signaling appliances flashing at 1 Hz over the strobe entire operating voltage range The strobe light shall consist a xenon flash tube and associated lens reflector system The strobe must be installed with its weatherproof back box in order to remain approved per UL The strobe shall be suitable for use in wet environments Strobe Combination horn strobe shall be a System Sensor SpectrAlert Advance Outdoor Model listed to UL 1638 and UL 464 and shall be approved fire protective service The horn strobe shall be wired as a primary signaling notification appliance and comply with the Americans with Act requirements for visible signaling appliances flashing at 1 Hz over the strobe entire operating voltage range The strobe light consist of a xenon flash tube and associated lens reflector system The horn shall have three audibility options and an option to switch a temporal three pattern and a non temporal continuous pattern These options shall be set by a multiple position switch On four products the strobe shall be powered independently of the sounder The horn strobe on a 2 wire model shall work on a non coded power The horn on 4 wire horn strobe models shall operate on a coded or non coded power supply The horn strobe must be installed with weatherproof back box in order to remain outdoor listed per UL The horn strobe shall be suitable for use in wet environments Specifications Temperature Flash Rate Voltage Voltage Range2 Voltage Range with MDL3 Sync Module Terminal Wire Gauge Dimensions Dimensions with Back Box Full Wave Rectified FWR voltage is a non regulated time varying power source that is used on some power supply and panel outputs Products will operate at 12 V nominal only for 15 and 15 75 cd to 151 to 66 flash per second 12 DC FWR or regulated 24 DC FWR1 to 17.5 V 12 V nominal or 16 to 33 V 24 V nominal to 17.5V 12 V nominal or 16.5 to 33V 24 V nominal to 18 AWG diameter 2.5 high 173 mm diameter 64 mm high diameter 2.25 high 180 mm diameter 57 mm high Current Draw Data Max Strobe Current Draw mA RMS Volts Volts Max Horn Current Draw for 4 Wire Horn Strobes mA RMS Pattern Volts Volts Max Current Draw mA RMS 2 Wire Horn Strobe Standard Candela Range 15 cd Input High Medium Low High Medium Low Input High Medium Low High Medium Low Volts Volts Max Current Draw mA RMS 2 Wire Horn Strobe High Candela Range 135 cd Volts Input High Medium Low High Medium Low Derating K series products used at low temperatures listed ratings must be reduced in accordance with table Output cd Candela rating at not use below 32 Input High Medium Low High Medium

Related Files