System Sensor Select Series Thermal Heat Eng Spec
File Preview
Click below to download for free
Click below to download for free
File Data
Name | system-sensor-select-series-thermal-heat-eng-spec-4795823601.pdf |
---|---|
Type | |
Size | 599.22 KB |
Downloads |
Text Preview
Programmable Thermal Detector and Engineering Specifications intelligent programmable thermal detector shall be a System Sensor model number 5351B 5351B IV 5351RB IV 5351H or 5351H IV The detector shall be an intelligent programmable thermal and shall connect with two wires to the fire alarm control panel signaling line circuit SLC The with thermal sensors shall be programmable to the following alarm settings Fixed temperature of 135 57 with an RTI rating for installation of FAST or Fixed temperature of 135 57 and have a rate of rise element rated at 15 8.3 per with an have RTI rating for installation of V2 FAST or better or Fixed high temperature of 190 88 with an RTI rating for installation of QUICK or better detectors shall provide address setting means on the detector head using rotary switches Because of possibility of installation error systems that use binary jumpers or DIP switches to set the detector are not acceptable detectors shall also store an internal identifying code that the control panel shall use to identify the type detector Systems that require a special programmer to set the detector address including temporary at the panel are labor intensive and not acceptable Each detector occupies any one of at least possible addresses on the SLC loop It responds to regular polls from the system and reports its type and detectors shall provide a test means whereby they will simulate an alarm condition and report that to the control panel Such a test may be initiated at the detector itself by activating a switch or remotely on command from the control panel There are two test methods functional magnet or heat method detectors shall provide two LEDs to provide 360 visibility The LEDs are placed into steady red by the control panel indicating that an alarm condition has been detected An output connection also be provided in the base to connect an external remote alarm LED sounder base and or relay optional accessories The external remote alarm can be interconnected to other sounder or relay for activating all devices in a space via a single alarming unit LEDs on the sensor are controlled by the panel to indicate sensor status Coded signals transmitted the panel can cause the LEDs to blink latch on or latch off Refer to the control panel technical for sensor LED status operation and expected delay to alarm detectors shall be low profile ceiling mount and wall mount capable and constructed of a UV resistant with multiple color options The detectors shall be plug in mounted into a twist lock base and from the mounting base to simplify installation service and maintenance Mounting base wiring shall be made by means of SEMS screws The detector shall allow prewiring of the base The base shall be mounted on a junction box which is at least 1.5 inches 3.81 cm deep The base shall be available to mount to standard junction boxes Suitable boxes include 4.0 10.16 cm square box with and without plaster ring 4.0 10.16 cm octagonal box 3.5 8.89 cm octagonal box Single gang box Agency Standards ANSI UL 521 Heat Detectors for Fire Protective Signaling Systems FM 3210 Heat Detectors for Automatic Fire Alarm Signaling 2018