System Sensor spectralert-sp2c-install and maint

File Preview
File Preview
Click below to download for free

File Data

Name system-sensor-spectralert-sp2c-install-and-maint-3810497265.pdf
Type PDF
Size 706.34 KB
Downloads

Text Preview

INSTALLATION AND MAINTENANCE INSTRUCTIONS SP2C Series Mount Speaker Strobes for Protective Signaling Systems use with the following models SP2C2415 SP2C241575 SP2C2430 SP2C2475 SPC24115 SP2C24177 Strobe Range through 115 candela models MDL module candela models only MDL module Rate Output Speaker Terminals Size to 18 AWG to 0.82 mm2 inches mm Dimensions 6.8 diameter mm Input volts or 70.7 volts 4000 Hz 1 2 1 and 2 Watts Range Range 32 cid 176 to 120 cid 176 F to 49 cid 176 C S4048 Speaker Strobe SENSOR Division of Pittway 3825 Ohio Avenue St Charles Illinois 60174 FAX 630 377 6495 rt or Full Wave Rectified to 33 volts DC or Full Wave Rectified to 33 volts DC or Full Wave Rectified to 33 volts DC 20 to 33 volts Full Rectified to 33 volts DC 21 to 33 volts Full Rectified flash per second with 1575 are listed at 15 candela UL1971 but will provide 75 candela on straight down with 15 30 75 95 115 and 177 listed for that candela This manual shall be left with the owner user of equipment Description National Fire Protection Association NFPA has pub standards and recommended practices for the described in this manual As a result the must be familiar with these requirements as well all local codes and special requirements of the authority jurisdiction SpectrAlert SP2C series ceiling mount speaker strobe be operated with distribution amplifiers having an out voltage of either 25 volts or 70.7 volts speakers operate at any one of four input power levels output sound level is selected at the time of installa but can be changed if necessary speaker is also equipped with a capacitive input to al for DC supervision SpectrAlert SP2C series ceiling mount strobe can be in systems using 24 volt panels having DC or full rectified FWR power supplies The strobes can also installed in applications requiring synchronization required or applications that do not require no module required SpectrAlert SP2C series ceiling mount speaker strobes designed to meet the requirements of most agencies these devices including NFPA The National Alarm Code UL CSFM MEA Also check with your Authority Having Jurisdiction for other codes or stan that may apply Supply Considerations For Strobes typically supply DC filtered voltage or FWR full rectified voltage The system design engineer must the number of units used in a zone based on the of panel supply Be certain the sum of all the device do not exceed the current capability of the panel are based on using the device current found Table 2 and must be the current specified for the type of power supply used Sizes designer must be sure that the last device on the circuit sufficient voltage to operate the device within its rated When calculating the voltage available to the last it is necessary to consider the voltage drop due to resistance of the wire The thicker the wire the less the drop Generally for purposes of determining the size necessary for the system it is best to consider all the devices as on the end of the supply circuit case wire size resistance AWG solid Approximately 8 ohms 1,000 ft AWG solid Approximately 5 ohms 1,000 ft AWG solid Approximately 3 ohms 1,000 ft AWG solid Approximately 2 ohms 1,000 ft Manuals Online Assume you have 10 devices on a zone and each 50 mA average and 2000 Ft of 14 AWG wiring to length outgoing return The voltage at the end of loop is 0.050 amps per device x 10 devices x 3 ohms ft x 2000 ft 3 volts drop same number of devices using 12 AWG wire will pro only 2 volts drop The same devices using 18 AWG will produce 8 volts drop Consult your panel specifications as well as SpectrAlert oper voltage range to determine acceptable voltage drop wiring must be installed in compliance with the Na Electrical Code NEC and applicable local codes as as special requirements of the authority having juris using the proper wire size This also includes all NFPA Standards ANSI UL 1480 UL 1971 and 760 1 Electrical connections Connect the speaker strobe as shown in Figure 1 Keep mind that even though the speaker and strobe are a mechanical unit they are electrically independent require separate power sources Do NOT loop electrical wiring under terminal Wires connecting the device to the control must be broken at the device terminal con in order to maintain electrical supervision 2 Voltage and Power Selection ol lo ol ls2J FROM NEXT OR EOL FROM SUPPLY NEXT OR EOL Supply power for strobe must be continuous for operation 1 Sound levels for each transformer power tap 10 ft 10 ft 2 Current draw of strobes The SP2C24177 strobes were only tested at the 20 33 Volt FWR limits and 16 33 Volt DC limits all other SP2C were only tested at the 16 33 Volt FWR DC limits Mean Method Mean Current mA Current mA Models Models Rush Current mA Models FWR FWR DC FWR DC FWR 75 140 101 126 144 173 122 163 198 230 156 212 232 291 300 208 241 FWR FWR DC FWR DC FWR 242 170 224 232 258 168 228 238 288 318 218 298 462 384 486 436 560 518 552 562 668 712 576 728 912 1104 872 1184 FWR FWR DC FWR DC FWR 177 188 252 91 118 179 182 237 91 115 116 179 184 244 177 186 238 118 176 187 244 115 175 174 249 108 126 170 171 234 RMS Method RMS Current mA Models FWR FWR DC FWR DC FWR 103 168 143 154 178 208 180 204 242 300 268 218 248 394 370 315 327 Manuals Online 4 Positioning for maximum brightness For maximum brightness unit must be mounted flash angles as shown See Figure 2 as an example of how to select a 1 4 Watt when a 25 volt amplifier is being used Notice that header SW1 has two shunts One shunt is used to either 25 or 70.7 volts input The other shunt is to select input power of 1 4 1 2 1 or 2 Watts 1 lists the UL reverberant and anechoic output levels for each power tap on the SP2C series ceil mount speaker strobes levels exceeding 130 rated signal voltage can the speaker Consequently an incorrect tap con may cause speaker damage This means that if a tap is selected when a 70.7V amplifier is being used damage may result Therefore be sure to select proper taps for the amplifier voltage input power combination being used SP2C series ceiling mount speaker strobe can be flush on a 4 x 4 x 2 1 8 back box Use two 8 32 x 1 pan head screws to attach the speaker to the back box Fig 3 3 Flush mount back box Manuals Online Limitations of Ceiling Mount Speaker Strobes either of the voltage select or power select shunts is not plugged into of the appropriate option positions the speaker will not sound and will be no trouble indication at the panel Always make sure that the speakers are tested after installation per NFPA regulations speaker may not be heard The loudness of the speaker meets or the current Underwriters Laboratories

Related Files