System Sensor ZCK-1 Manual

File Preview
File Preview
Click below to download for free

File Data

Name system-sensor-zck-1-manual-9263150847.pdf
Type PDF
Size 1.04 MB
Downloads

Text Preview

INSTALLATION AND MAINTENANCE INSTRUCTIONS ZCK 1E ZCK 1EG and ZCK 50 Key Switch for Control and of the Zonecheck Flow Switch Tester SPECIFICATIONS Voltage Temperature Humidity Options Modes Operation switch activation 120V 60Hz ZCK 1E ZCK 1EG and ZCK 50 220VAC 50Hz 7.5W Max to 49 32 to 120 to 95 RH non condensing back box for surface or flush mounting pre wiring use a 411 16 x 411 16 back box Test Wired locally Timed out pump disabled after 2min Test Interconnected state No LED initiation Green LED LED ZCK 1 Green LED ZCK 1E ZCK 1EG and ZCK 50 Tested to EN 60335 1 3825 Ohio Avenue St Charles Illinois 60174 FAX 630 377 6495 DIAGRAM FOR STAND ALONE APPLICATION Zonecheck key switch features a time out function in Self Test mode that the user to start the flow switch test which will end automatically after minutes The waterflow detector will be activated during the 2 minute upon activation the waterflow detection LED on the zonecheck switch will turn on and remain that way until the key is returned to the position EARTH GND ATTACH TO BOX GROUND POWER this product is not used as specified it may become impaired 1 WIRING DIAGRAM FOR STAND ALONE APPLICATION DIAGRAM FOR STAND ALONE APPLICATION INPUT EARTH GND ATTACH TO BOX GROUND INTERCONNECTING MULTIPLE ZONECHECK UNITS 2 FOR INTERCONNECTING MULTIPLE ZONECHECK UNITS EARTH GND ATTACH TO BOX GROUND POWER INTERCONNECTING MULTIPLE ZONECHECK UNITS INPUT EARTH GND ATTACH TO BOX GROUND POWER POWER INPUT WF INPUT not required for key switch operation if waterflow detec is connected to a panel or other monitoring device AC power and pump must conform to NEC or your local codes ZCK 1EG AND ZCK 50 the pump used in this application is grounded it must share the same in earth ground as the device overcurrent protection device such as a switch or circuit breaker is re The protection device must be clearly marked and have a maximum of 16 A NEXT FOR are no ventilation requirements GUIDELINES central monitoring station or appropriate fire safety personnel prior testing Zonecheck INPUT EARTH GND ATTACH TO BOX GROUND POWER INPUT EARTH GND ATTACH TO BOX GROUND POWER INPUT NEXT FOR activate the Zonecheck key switch when the valves are opened and the system is full TESTING SELF TEST MODE activate the Zonecheck wired locally to the key switch insert key and turn the right The green LED will illuminate to show that the pump has been After two minutes the green LED will turn off to show the pump been deactivated The red LED will illuminate once the waterflow detector been activated and will remain on until the key is returned to the standby The red LED will not illuminate if the waterflow detector is not wired the key switch When testing has been completed turn the key back to the position ZCK 1EG AND ZCK 50 activate the Zonecheck wired locally to the key switch insert key and turn the right Green LEDs will illuminate when either the pump or the water detector are activated After two minutes the pump led will turn off that the pump has been deactivated The water flow detection LED remain on until the key is returned to the standby position The LED for the waterflow detector will not illuminate if the detector not wired to the key switch When testing has been completed turn the key to the standby position TESTING GROUP TEST MODE Zonecheck systems whose key switches are interconnected refer to inter wiring diagram may be activated from any key switch To initiate group test insert key and turn to the left LEDs on the key switch used to initiate the group test indicate the activity the Zonecheck unit and waterflow detector connected to that key switch only testing has been completed turn the key back to the standby position refer to insert for the Limitations of Fire Alarm Systems Limited Warranty Sensor warrants its enclosed product to be free from defects in materials and under normal use and service for a period of three years from date of System Sensor makes no other express warranty for the enclosed product agent representative dealer or employee of the Company has the authority to in or alter the obligations or limitations of this Warranty The Company obligation this Warranty shall be limited to the replacement of any part of the product which is to be defective in materials or workmanship under normal use and service during three year period commencing with the date of manufacture After phoning System toll free number 800 SENSOR2 736 7672 for a Return Authorization number defective units postage prepaid to Honeywell 12220 Rojas Drive Suite 700 El Paso 79936 USA Please include a note describing the malfunction and suspected cause failure The Company shall not be obligated to replace units which are found to be because of damage unreasonable use modifications or alterations occurring the date of manufacture In no case shall the Company be liable for any consequen or incidental damages for breach of this or any other Warranty expressed or implied even if the loss or damage is caused by the Company negligence or fault states do not allow the exclusion or limitation of incidental or consequential dam so the above limitation or exclusion may not apply to you This Warranty gives you legal rights and you may also have other rights which vary from state to state System Sensor 06 10

Related Files