Valcom v-136rt

File Preview
File Preview
Click below to download for free

File Data

Name valcom-v-136rt-1720854693.pdf
Type PDF
Size 921.33 KB
Downloads

Text Preview

VSP V 136RT 7 STATION ROTARY TONE INTERCOM V 136RT is a single path dial select controlled intercom and page control used with a 1A2 key system to provide 36 zones bell or buzzer signalling V 136RT control unit has received an FCC type registration designed to be used with FCC key telephone systems In accordance with rules with applicable tariffs this paging unit only be installed with the authorization of the system Installations may be made by Valcom an authorized agent of the same equipment telephone companies registered refurbishers and those qualified for of FCC registered systems under FCC Section 68.215 The FCC Registration BAF9I7 69366 KX N will be listed in the filed with the telephone company it will be be recorded in the system log kept by installation maintenance personnel The local telephone is to be notified when this intercom unit is Dial tone Ringback tone Last number dialed rering Conference call tone only Combined rotary or tone dialing Dial ringback tone mute Mixed bell and buzzer operation Single or double burst signaling Plan The dialing codes are 0 5 39 x 5.9 W x 2.1 D x 14.99cm x 5.33cm lbs 1.47 kg Requirements Battery Battery Limits Current to Vdc 90mA to Vdc 350mA Characteristics Imp T and R Contacts Time Pulses Limits ohm incl inst amps second PPS Break ratio 10 Standard Frequencies Time 40MS to 50o to 85 Manuals Online precautions have been taken at the factory to that the equipment functions properly when correctly Please observe the following before applying power to the equipment the equipment may be damaged and the warranty Unplug the power supply before making any to the control unit Do not locate the control unit closer than 18 or further than 5 feet from the power Do not use a lamp tester to check signals use a A lamp tester when first applied is a circuit to electronic circuits Do not apply power to the control unit until all have been double checked the V 136RT on a 7 KTU mounting relay or on the wall Fasten a 25 pair cable to the unit and terminate leads on a 66 type block per Figure 1 2 or 3 Strap 1 ground B ground lamp ground 18 Vac 105 Vac signal grounds common at power Refer to Figure 1 for connections use the chart Figure 1 to set the option programming Option switches 3 and 4 must be in the off for proper operation with bells or Refer to Figure 2 for connections for 36 stations buzzer signalling This figure may also be for 36 stations of bell signalling by the 18 Vac buzz voltage with 105 ring voltage Refer to Figure 3 for connections for mixed with 20 stations of bells and 16 of buzzers make an intercom call go off hook and dial the of the desired station Dial tone will be after the first number is dialed A one second tone will indicate that the called station is signalled rering the same station press the button The will be signalled as long as the button is To rering rotary dial 1 The station will be for one second each time a 1 is dialed conference calling tone only dial the first number press the button to receive dial then dial the next station number Method of Operation the calling party goes off hook the switch contacts in the telephone set close the tip and to form a loop Loop closure detection logic operates the lamps at all stations and returns dial to the telephone set Dial detection circuitry will receive dialing information and operate relays circuitry to supply signalling voltage to the station ASSISTANCE trouble is reported verify that All telephone sets are in proper working order Power is being supplied to the unit There are no broken connections at the block The conductors of color coded cables are in the proper order trouble still exists additional checks should be using the following equipment Voltmeter Tone dial single line instrument for tone dial Telephone Test Set Clip leads proceeding further check the voltages at the block An undetected blown fuse or low will cause improper control operation DC measurements are made with respect to a spare unit is available continue to troubleshoot substituting the spare unit for the suspected unit the trouble has not been located refer to the Chart Identify the symptoms and the corrective actions indicated After all the tests have been performed the trouble still call Valcom at 540 427 3900 and ask for Manuals Online Support or call 540 427 6000 for 24 hour Automated Support or visit our at http www valcom com equipment is not field repairable Valcom maintains service facilities in Roanoke VA repairs be necessary attach a tag to the unit stating company name address phone contact person and the nature of the Send the unit to Inc and Return Dept Hollins Road VA 24019 5056 CHART ACTION side tone dial tone lamps A battery connections polarity and voltage option switch 1 Check B battery connections polarity and lamp supply voltage and input Verify that grounds are common power supply audible signal at station dialed signal voltage at supply and frame locations Verify bell and returns are common at power supply signaling option switch 2 signaling Stations 10 through 29 Stations 30 through 39 0 and 5 through 9 option switch 3 option switch 4 Inc warrants its products to be free from defects in materials and workmanship under conditions of normal use and service a period of one year from the date of shipment The obligation under this warranty shall be limited to the replacement repair or of any such defective device within the warranty period provided that LIMITED WARRANTY by Valcom Inc indicates the validity of the claim defect is not the result of damage misuse or negligence after the original shipment product has not been altered in any way or repaired by others and that factory sealed units are unopened A service plus parts and labor will be applied to units defaced or physically damaged charges for the return of products to Valcom are prepaid units of warranty are subject to a service charge The service charge will cover minor repairs Major repairs will be to additional charges for parts and labor warranty is in lieu of and excludes all other warranties expressed or implied and in no event shall Valcom Inc be for any anticipated profits consequential damages loss of time or other losses incurred by the buyer in connection the purchase operation or use of the product warranty specifically excludes damage incurred in shipment In the event a product is received in damaged condition the should be notified immediately Claims for such damage should be filed with the carrier involved in accordance with the point Canada Manuals Online Inc Industry Avenue VA 24013 540 427 3900 540 427 3517 Corporation Van Kirk Drive 11 and 12 Ontario L7A1A5 905 456 1072 905 456 2269 Manuals Online B C E F BELL BUZZER GROUP ONE STATIONS 10 29 BELL BUZZER GROUP TWO STATIONS 30 39 0 5 9 AUDIBLE SIGNAL 18VAC BUZZ OR 105VAC RING POWER SUPPLY A BAT 24VDC FILTERED TALK BATTERY B BAT 24 VDC UNFILTERED BATTERY AUDIBLE GND LAMP GND A GND AND B GND MUST BE COMMON AT POWER SUPPLY OPTION PROGRAMMING DIAL DOUBLE

Related Files