SINGLE ZONE PAGE CONTROL UNIT 1 V 2000A is an Integrated Single Zone Paging Unit for use with any electronic key or The control unit provides external power 12 power units for powering Valcom One Way Speakers instructions contain the specifications and necessary to install operate and maintain Integrated Single Zone Paging Control Unit To reduce the risk of fire or shock do not expose this appliance rain or moisture Shock Hazard Do Not Open Risque de Choc Electrique ne pas Corriente Elecrica No Abra Provides telephone system access to a single of one way paging Key Systems 400 type line card required Electronic Key Systems PABXs Stand Alone Systems to Figure 1 for a block diagram of a typical Electronic key system line key access PABX loop start trunk port access Page port access Switchable battery feed for loop start operation RJ11 for Tip and Ring connections Power on LED Drives up to 150 Valcom one way amplified assemblies audio Background music input Voice operated switch to mute music during page Screw terminals provided for all connections UL Listed Supplies 12 Valcom power units for powering one way amplified speakers May be used with 25 or 70 volt amplifiers AC powered AC input fused at 5 amp The V 2000A is a one zone single talkpath unit Each V 2000A will drive up to 150 Valcom amplified speaker assemblies audio provides 12 Valcom power units for the speaker amplifier assemblies The can also be used to access 25 or 75 volt amplifiers Manuals Online VALCOM ONE WAY SPEAKERS E KEY PABX V 2000A ZONE SYSTEM Additional power supplies required for large numbers of speakers 1 TYPICAL INSTALLATION x 7.7 W x 5.3 D H x 19.6cm W x 13.5cm D lbs 1.2 kg Power Requirements Voltage Current Vac Amp Temperature Humidity to 40 C 32 to 104 F to 85 non precipitating Ohms nominal to 600 Ohms nominal Ohms nominal Vdc at 600 mA Specifications Impedance Level Source Input Impedance Switch Sensitivity Input Level Impedance Level Output DESIGN Valcom V 2000A Integrated Single Zone Page Unit provides access to paging from a PABX loop start trunk port an Electronic System C O line button or a 1A2 Key System O line button a 400 type line card is required In cases access is also possible from a PABX or Key System page port Key or PABX Access using the V 2000A with an electronic key or PABX the following equipment will be 1 V 2000A Integrated Single Zone Page Control 1 C O Line Circuit Electronic key system or 1 Start Trunk Circuit PABX Valcom One Way Amplified Speaker Assemblies and style determined by specific Press the appropriate line key electronic system or dial the appropriate trunk access code You will immediately be connected to the speakers Make announcement The will automatically disconnect when you up Port Access accessing the V 2000A from a page port the equipment will be required One V 2000A Integrated Single Zone Page Unit Telephone system page card required for external page outputs Valcom One Way Amplified Speaker quantity and style determined by installation Follow the telephone manufacturers on how to access external paging You immediately be connected to the paging speakers announcement The V 2000A will disconnect when you hang up Music music may be connected to the V 2000A using any of the above configurations The music will cut off automatically when the making the page is speaking Manuals Online Designations cid 5 cid 9 cid 6 cid 5 cid 1 cid 9 cid 6 cid 1 cid 12 cid 21 cid 12 cid 11 cid 9 cid 19 cid 12 cid 11 cid 27 cid 18 cid 15 cid 18 cid 25 cid 9 cid 16 cid 10 cid 9 cid 14 cid 29 cid 22 cid 18 cid 21 cid 18 cid 12 cid 13 cid 9 cid 19 cid 12 cid 11 cid 27 cid 18 cid 15 cid 12 cid 9 cid 31 cid 12 cid 11 cid 19 cid 10 cid 25 cid 25 cid 12 cid 22 cid 28 V 2000A was designed for wall or table The intended mounting orientation will the text on the enclosure lid legible when the is viewed When wall mounting this unit secure to wall studs or a suitable brace A plywood 2 square and at least 1 2 thick attached to studs would be considered a suitable brace certain the unit is not mounted near heat or strong magnetic fields Ascertain control terminal strip accessibility 10 x 3 4 cross tip round head wood screws included for mounting Fasten the top two screws the appropriate location on the mounting surface 3.65 apart and parallel to the floor the screwheads to protrude 1 8 to 1 4 the chassis of the unit onto the screwheads at mounting slots Position the two remaining and fasten through the remaining mounting Complete the mounting by tightening all Connections V 2000A is provided with a three conductor line After all required connections have been plug the cordset into appropriate AC wall Adjustments on the front cover of the V 2000A are the adjustable volume controls for regulating page and background music level Each volume is set by turning it clockwise to increase the and counterclockwise to decrease the volume a b Level During initial system set up it recommended that the individual speaker controls on the amplified speaker be adj

Related Files