Valcom v-2970
File Preview
Click below to download for free
Click below to download for free
File Data
Name | valcom-v-2970-6538720194.pdf |
---|---|
Type | |
Size | 1023.40 KB |
Downloads |
Text Preview
VSP V 2970 2 CALL SWITCH VOLUME CONTROL V 2970 is an Emergency Normal Call Switch Volume Control designed to be used with the V and V 2925 Page Control Units The V 2970 provided with an Emergency call button and a call button for connection to customer signaling equipment Emergency button transposes a single press of button into the four required closures required to an Emergency class of service call The call button allows a Normal class of call x 2.75 x 1.0 H x 6.98cm W x 2.54cm D lbs 09 kg Designed to fit a single gang electrical box No external power source required Red Emergency button for emergency call Black Call button for normal call Built in Volume Control Connect switch inputs from control unit to V as shown in connection diagram Connect Tip and Ring from control unit to V as shown in connection diagram Connect V 2970 to Tip and Ring of 45 ohm Speaker Press either call button to test loudness of tone at and adjust volume of tone through cut on the front of the V 2970 enclosure using a flat tip screwdriver Place V 2970 over standard single gang box and fasten in place using the two provided ASSISTANCE trouble is reported verify that power is being to the unit and there are no shorts or grounds cabling in troubleshooting is available from the When calling you should have a VOM and telephone test set available and be calling from the site Call 540 427 3900 and ask for Technical or 540 427 6000 for Valcom 24 hour Support or visit our website at equipment is not field repairable Valcom maintains service facilities in Roanoke VA repairs be necessary attach a tag to the unit stating company name address phone contact person and the nature of the Send the unit to Inc and Return Dept Hollins Road VA 24019 5056 Manuals Online Inc warrants its products to be free from defects in materials and workmanship under conditions of normal use and service a period of one year from the date of shipment The obligation under this warranty shall be limited to the replacement repair or of any such defective device within the warranty period provided that LIMITED WARRANTY by Valcom Inc indicates the validity of the claim defect is not the result of damage misuse or negligence after the original shipment product has not been altered in any way or repaired by others and that factory sealed units are unopened A service plus parts and labor will be applied to units defaced or physically damaged charges for the return of products to Valcom are prepaid units of warranty are subject to a service charge The service charge will cover minor repairs Major repairs will subject to additional charges for parts and labor warranty is in lieu of and excludes all other warranties expressed or implied and in no event shall Valcom Inc be for any anticipated profits consequential damages loss of time or other losses incurred by the buyer in connection the purchase operation or use of the product warranty specifically excludes damage incurred in shipment In the event a product is received in damaged condition the should be notified immediately Claims for such damage should be filed with the carrier involved in accordance with the point Inc Industry Avenue VA 24013 540 427 3900 540 427 3517 Canada Corporation Van Kirk Drive 11 and 12 Ontario L7A1A5 905 456 1072 905 456 2269 CONNECTIONS ear of Unit olum e Control ohm pot c c es s ible from and rear unit 2924 2925 S W 2924 2925 S W peak er Tip In peak er Ring In O ut O ut O HM TA LK B A CK P E A K E R CO NNE CTIO NS NTRO L UNIT NNE CTIO NS Manuals Online