Valcom v-9927a

File Preview
File Preview
Click below to download for free

File Data

Name valcom-v-9927a-6830247195.pdf
Type PDF
Size 1.03 MB
Downloads

Text Preview

VSP V 9927A 3 MULTI TONE GENERATOR V 9927A was designed with ease of installation flexibility in mind Connections are by screw located on the edge of the PCB The options and tones are set using option blocks inside the enclosure on the PC Board V 9927A is a microprocessor controlled multi generator capable of producing a variety of tone for various applications It is functional and compatible with the previous V 9927 check all wiring as connections to the unit different equipment has been tested and found to comply the limits for a Class A digital device pursuant Part 15 of FCC Rules These limits are designed to reasonable protection against harmful when this equipment is operated in a environment This equipment generates and can radiate radio frequency and if not installed and used in accordance the instruction manual may cause harmful to radio communications Operation of equipment in a residential area is likely to cause interference in which case the user will be to correct the interference at his her own Dimensions 8.2 X 4.55 X 2.3 20.83cm H x 11.56cm W x 5.84cm D Requirements 24VDC Battery 100mA Environment Temperature 0 50 degrees C Humidity 0 85 non condensing Input Output Specifications Input Impedance 600 Ohms Output Impedance Less than 4 Ohms Min Output Load Impedance 20 Ohms Audio Input 0dBm Nominal Max Tone Output 1Vrms single tone 1.5 lbs 68 kg is intended for wall mounting only When mounting open enclosure and remove circuit board Screw back enclosure to backboard near the telephone system common equipment Snap circuit board back in place Both holes must be utilized to insure secure mounting of the unit connections and set tones using option blocks as required for the specific application Refer to Tone Table on 2 for tone descriptions cover and plug in power supply Manuals Online Tones except Code Call of the V 9927A is accomplished by applying a connection between the COM Common terminal on the block and the desired tone 1 8 Tone selected by terminal 1 has priority over others If multiple tone inputs are being used it is possible to tones by closing the appropriate contacts in the desired sequence However Tone 1 will always be placed on the list when it has been activated multiple tones are selected at the same time the LOWEST tone number will have priority If the lowest contact is then the next lowest tone number will be activated a Tone is activated the INPUT source will be faded out in 0.75 seconds if P5 is out or will be faded out in seconds if P5 is IN V 9927A has a buffer for 32 tones If more than 32 tones are entered within a short period the V 9927A drop the last tone entered 2 illustrates several of the ways the V 9927A can be used with other Valcom equipment Call Operation the V 9927A is connected to the V 9923A code call unit the V 9927A will respond to the contact closure and issue single chimes in response See Figure 2 the beginning of a Code Call sequence the INPUT source will be faded down about 6dB It will remain at this until the CODE CALL sequence has completed including the interdigit time At that time the INPUT source be faded back up to normal level using the CODE CALL option with other tone options the CODE CALL may be interrupted to place other in the sequence including Tone 1 with higher priority However the CODE CALL may be out of sequence the period that this occur ON TABLE TONE 1 TONE 2 TONE 3 TONE 4 TONE 5 TONE 6 TONE 7 TONE 8 TONE 1 TONE 2 TONE 3 TONE 4 TONE 5 TONE 6 TONE 7 TONE 8 WHOOP 698 Hz 3.9 sec approx cycle 2 cycle min DUAL CHIME 880 Hz 698 Hz BURST 880 Hz 1 2 sec on 2 min STEADY 880 Hz 3 sec min 986 784 Hz 11 sec 10 minimum 986 784 659 523 Hz order 880 698 587 494 Hz order CALL CHIME 784 Hz V 9923A standard SIREN 659 Hz center 1 cycle approx 0.3 Hz WHOOP yelp 659 Hz 2.5 Hz 4 min WARBLE 494 986 Hz 6 Hz rate STEADY 698 Hz 1 sec minimum BURST pulse 494 Hz 4.5 Hz rate 659 784 Hz 986 784 Hz CALL CHIME 784 Hz V 9923A Standard denotes V 9927 compatible tones denotes Standard Immediate Evacuation signal for industrial areas Manuals Online Blocks Jumpers shown in factory default setting 1 BANK SELECT with the V 9927 P3 to IN position P1 for BURST or CONT as required P4 to UNMUTE P5 to IN inputs 1 4 correspond to WHOOP BURST and STEADY CALL is available on TONE input 8 for Level LED when power present ON COM to Tone In of Jumpers COM SIGNAL SIGNAL 24V IN OUT Supply 24VDC BURST CONT Sets the mode of the V 9927A The BURST function allows one 1 tone or sequence each closure of the TONES input The CONT function is continuous the tone or sequence will while the closure on the TONES input 1 8 remains activated TONE BANK Select OUT IN Activates tones Refer to the Tone Table page 2 to determine jumper for the desired tones UNMUTE MUTE Determines if SIGNAL IN is muted or unmuted With UNMUTE selected the signal after completion of a designated tone or sequence even if the relay on the TONES input 1 8 connected With MUTE selected the signal remains off after completion of tones even if the relay the TONES input 1 8 is connected OUT IN Determines the fadeout duration of the Input Source The INPUT source will be faded out in 0.75 if P5 is OUT or will be faded out in 0.25 seconds if P5 is IN P6 Not used on this version Manuals Online ASSISTANCE trouble is reported verify the unit in question is turned on the green ON LED should be observed and all are secure Assistance in troubleshooting is available from the factory When calling you should have VOM available and be calling from the job site Call 540 427 3900 and ask for Technical Support or call 540 for Valcom 24 hour Automated Support or visit our website at http www valcom com equipment is not field repairable Valcom maintains service facilities in Roanoke VA Should repairs be attach a tag to the unit clearly stating company name address phone number contact person and the of the problem Send the unit to Inc Return Dept Hollins Road VA 24019 5056 Manuals Online

Related Files