Valcom v-9936a

File Preview
File Preview
Click below to download for free

File Data

Name valcom-v-9936a-8165724390.pdf
Type PDF
Size 1.52 MB
Downloads

Text Preview

VSP V 9936A 4 LINE C O AUDIBLE RING UNIT V 9936A is a Six Line C O Audible Ring Unit be used with Electronic key and PABX telephone instructions contain the specifications and necessary to install operate and maintain Six Line C O Audible Ring Unit installing the V 9936A notify the local company with the following information The telephone number of the lines to which the will be connected The FCC Registration number of the V 9936A is BAF9I7 12995 RG N and The ringer equivalence number REN 0.7B Monitors up to six C O Lines or PABX station and gives a common audible tone signal a dry relay contact closure to indicate ring on any of the lines V 9936A units may be multiplied to supervise lines Electronic key system C O lines PABX trunks PABX station numbers key system C O lines Monitors six lines Units may be multiplied for additional lines Provides interrupted electronic warble tone for tone signaling Provides interrupted dry contact closure output to loud bells for a night switch On Off switch Built in 66 type connection block May be connected to an existing paging system Drives up to 150 Valcom One Way Amplified Assemblies Drives up to two 45 Ohm Talkback Speakers May be used with One way or Talkback Paging May be used with 70 Volt Paging Systems Ring tone will override any page in progress Volume control Power reversal indicator Powered by Vdc B battery Each V 9936A will provide signaling for six lines or extension numbers Up to four units may be multiplied for of 24 lines May be connected to one zone of a paging The V 9936A will drive two 45 Ohm Talkback or 150 one way amplified speaker The dry contact closure is rated at 1.0 amp Vac or 2.0 amps 24 Vdc Manuals Online x 4.55 W x 2.3 D H x 11.56cm W x 5.84cm D lbs 68 kg Requirements to Vdc B Battery 200 mA max to 50 Degrees C to 85 non precipitating Valcom V 9936A is designed to monitor up to C O lines or PABX station numbers and will a common tone signal and contact closure any of the lines are ringing The V 9936A be used with most telephone systems because it directly to the lines and not to the phones tone output may be connected to speakers used for ringing or to one zone of a paging system dry contact closure may be used to activate loud bells strobes or other external equipment outputs will provide interrupted signals any line is ringing disable input is provided for connection of a night With no switch connected the V 9936A signal any time a line rings in With a switch and providing a short across the disable the unit will be inactive Ringing following components are required to provide audible ringing over dedicated bells or V 9936A C O Ring Units 1 per 6 lines Signaling Devices consisting of Two 45 Ohm talkback speakers or Up to 150 one way amplified speakers or Loud bells buzzers strobes etc as required Power Supply The VP 624B will power a using talkback speakers for signaling one way speaker assemblies or other signaling are used additional power may be Over Paging may be connected to one zone of a Valcom or Talkback Paging System or to the of a high powered amplifier The following are required V 9936A C O Ring Units 1 per 6 lines VP 624B Vdc Power Supply VP 4024B if using more than 3 V 9936A a page is in progress when an incoming call is the ring signal from the V 9936A will override the page cid 31 cid 13 cid 19 cid 31 cid 13 1 TYPICAL INSTALLATION following sections contain step by step for wiring the V 9936A and associated equipment Each instruction is preceded by a place a check on the appropriate line as the is completed The instructions also tests along the way to verify connections have made correctly If these steps are followed installation should go smoothly and quickly the results of a test do not correspond with what is DO NOT PROCEED UNTIL THE HAS BEEN CORRECTED individual volume controls at approximately 1 2 for testing when installing the control unit any one way amplified speaker assemblies the metal mounting plate from the rear of the enclosure Using two 6 3 4 wood screws the plate in a vacant space on the backboard the telephone system common equipment Both holes must be utilized to insure secure of the unit See Figure A the V 9936A enclosure to access connections option switches Slide the rear of the unit the board onto the mounting plate and lock place with screw provided Make connections and cover after all connections are accomplished cover in place using the 6 1 2 screw provided Manuals Online REMOVE COVER SCREW ACTIVATE LATCH TIE LOOP TIE USED TO BUNDLE WIRES AND LEAVING TERMINAL AREA OPENING WALL PLATE AND BOX WALL LATCH BOARD ASSEMBLY DIA HOLES FOR MOUNTING TO OR DOUBLE GANG JUNCTION BOX PATTERN MATCHES BOTH EURO US JUNCTION BOXES x 2 WIRE ACCESS OPENING JUNCTION BOX LATCH COVER A Manuals Online NOT locate the V 9936A or it wiring than 18 to a power supply or any that generates electrical noise Connections The steps below must be completed for each being installed 1 Unplug power supply 2 Connect Vdc B battery may be to as or signal battery from supply to pin 30 24 Vdc on the 3 Connect Vdc Ground B ground signal ground from power supply to 29 GND 4 Connect Vdc ground from power to telephone system GND 5 Power Test Plug in power supply If power reversal LED is lit not lit go to step 6 Unplug power supply Reverse connections on V 9936A pins GND and 30 Vdc 6 Unplug power supply Go to step 6 2 Power LED Not Adjust Control Select Switch Block OF CONNECTING BLOCK AND CONTROLS CLOSURE OUT OUT T OUT IN OUT IN T TIP TIP TIP TIP TIP TIP 8 7 6 5 4 3 2 1 14 13 12 11 10 29 28 27 26 25 24 23 22 21 20 19 18 17 16 BLOCK PIN DESIGNATIONS Manuals Online Arrangements Proceed to Figure 3 for Stand Alone Ringing Proceed to Figure 4 for Ringing Over

Related Files