V 9963 FEEDBACK ELIMINATOR 4 DESIGN V 9963 is designed to eliminate acoustic When a page is made the message is and saved Upon completion of the live the message is released for broadcast over speakers While this page is being broadcast page can be recorded This eliminates the squeal of feedback commonly produced by or microphones when making a page Automatic Gain Control AGC Adjustable VOX Sensitivity Two Input Channels selectable for primary and priority or dual with equal priority inputs are switch selectable for loop start Ohms or VOX activation Two Audio Outputs Out 600 Ohms to Page Control Unit level 8 Ohms to Amplified Speakers Background music input adjustable Three Normally Open Output Relays Record Busy Four LED Indicators Power On Play Record Busy Dip Switch Programmable Message Cancelling Easy to install in new or existing systems Solid State DSP storage and playback High Fidelity CD Sound Reproduction Loop Start Trunk Port C O Line Position Page Port Line Level Audio Feed x 7.8 W x 2.2 D H x 19.81cm W x 5.59cm D lbs 1.18 Kg Specifications Ohms Impedance dBm Level Ohms Out Output Impedance Ohms Level Output Impedance dBm nominal Level dBm to 35 dBm Sensitivity time after last sensed audio seconds duration of recorded page 60 seconds number of stored pages Primary Priority Mode Call Stacker Mode Response Music Hz to 7 kHz Hz to 17 kHz to 40 Degrees C to 85 non precipitating Notice equipment has been tested and found to comply the limits for Class A digital devices pursuant to 15 of FCC Rules These limits are designed to reasonable protection against harmful when the equipment is operated in a environment This equipment generates and can radiate radio frequency energy and if installed and used in accordance with the manual may cause harmful interference to communications Operation of this equipment a residential area is likely to cause harmful in which case the user will be required to the interference at his own expense Manuals Online is recommended that Category 3 or 5 twisted wire be used in all Valcom speaker A screw type connector strip is to allow connection of all wiring to the V V 9963 is wall mountable using screws Connection Access Remove the small side panel to access all and terminations To remove panel loosen two screws holding the panel in place and lift away from the board Treatment If the input signal to the V 9963 exceeds nominal levels specified attenuate the signal a V 1092 This situation would apply when the output of a Valcom Talkback Page Control is as a One Way Page input to the V 9963 Tip1 Ring1 or Call Stacker Line 1 Input primary input is the path normally used to access unit for recording and playback of a page Method Start Trunk Port System C O Line Key Alone Telephone Set Port w Contact Closure Port w o Cont Closure Page Cntrl Output 600 ohm Output Output using C C OFF OFF OFF OFF ON ON OFF OFF ON ON ON OFF OFF OFF ON Settings Tip2 Ring2 or Call Stacker Line 2 Input access will override primary input activity Settings Method ON Start Trunk Port System C O Line Key ON ON Alone Telephone Set OFF Port w Contact Closure OFF Port w o Cont Closure Page Ctrl Output OFF ON 600 ohm Output Output using C C OFF OFF OFF OFF OFF ON ON OFF OFF 1 Input Primary Port or Line 1 External Dry Contact Closure to activate sequence Also see Note for 4 3 2 Input Priority Port or Line 2 External Dry Contact Closure to activate sequence Input low level music source Ex V 2952 Out ohm output connects to Self Amplified Valcom Amplifier Inputs or other audio devices Out ohm output connects to T R input of Valcom Page Controllers or other audio devices Adjustment Pot Background Music Level output abort a message during play use the External Closure input to manually stop message To abort a message during press any number on the dial pad of the Closure Outputs PLYSW and PLYMK Open Contact Closure output that is closed message plays RECSW and RECMK Open Contact Closure output that is closed message records PRISW and PRIMK Open Contact Closure output that is closed unit cannot accept any more pages Program Dip Switches are several controls and switches on the board programming the options of the V 9963 Refer to 1 page 4 for location of switches and Dip Switches OFF Left ON Right Primary Port or Line 1 Battery Feed battery feed supplied to primary port feed supplied to primary port Manuals Online Priority Port or Line 2 Battery Feed battery feed supplied to primary port feed supplied to primary port The 8 position dipswitch provides DTMF Signaling Options DTMF signal single zone signal accepted multi zone SW3 3 Number of digits to receive recording announcement digit digits digits digits OFF OFF ON ON OFF ON OFF ON Priority Port Mode primary and priority pages page broadcasts first page broadcasts in real time page in progress is recorded and broadcast after priority page Message Playback Control message once message twice SW3 7 Pre Page Alert Tones Tone Tone Tone Tone OFF ON OFF ON OFF OFF ON ON Inter Page Timing second between pages seconds between pages ON The 4 position dip switch provides Primary or Line 1 Page Access Detect Detect VOX Priority or Line 2 Page Access Detect Detect VOX Pre Tone Enable Disable 3 sec delay of to Record and Sequence tones are issued when is activated Allows immediate Activation with a contact closure This option is effective only when the inputs set at Loop Detect SW 4 1 OFF Normal or Call Stacker Mode Inputs Primary and Priority Inputs will function as Call Stacker Switches and Controls VOX Sensitivity sets threshold for detection audio on the primary and priority ports Indicators Illuminates when announcement is playing Illuminates during recording of the Illuminates if for any reason the unit cannot any more pages Illuminates when Vdc and GND is to the unit ASSISTANCE trouble is reported verify the unit is turned on there are no broken connections leading to the in troubleshooting is available from the When calling you should have a VOM and a test set available and be calling from the site Call 540 427 3900 and ask for Technical or 540 427 6000 for Valcom 24 hour Support or visit our website at equipment is not field repairable maintains service facilities in Roanoke Should repairs be necessary attach a tag to the clearly stating your company name address number contact person and the nature of the Send the unit to Inc and Return Dept Hollins Road VA 24019 5056

Related Files