Valcom VP-6124-UPS

File Preview
File Preview
Click below to download for free

File Data

Name valcom-vp-6124-ups-2096317854.pdf
Type PDF
Size 1023.04 KB
Downloads

Text Preview

VSP VP 6124 UPS 2 ON OPTION FOR THE VP 6124 VP 6124 E SUPPLY VP 6124 UPS is an optional unit that allows the to supply power during a power VP 6124 UPS is comprised of a VP 6124 UPS and a VBB 1424 Battery Enclosure The connects to the VP 6124 Power to receive power to charge the batteries below are specifications and recommendations power sources as well as precautionary Float Standby Charging Voltage Limit volts 13.8 per battery mA charging mA at 27 volt final charge amp auto reset polyswitch amp accidental reverse battery polyswitch Required to Recharge Battery battery hours of Time Battery will Provide With four 7AH 12V batteries for 14AH total of batteries greater than 7AH is not recom since 90 of all power outages are less than hour in length and the time to evacuate a building less than an hour amp load draw amp full load hours run time hours run time To insure troublefree UPS back up five year batteries must be replaced five from the date of manufacturing H x 3.5 W x 2.25 D H x 8.89cm W x 5.72cm D lbs 1.32 kg VP 6124 UPS charger is designed for wall only Screw mounting plate to the wall the VP 6124 VP 6124 E and position the onto the mounting plate the UPS unit securely to the bracket lip using 6 32 x 3 8 long Phillips head self tapping screw Place the VBB 1424 on the floor within six of the unit Disconnect AC power from the power supply Remove plug button from the Remove wire access cover from the Using the cable designated by the tag labeled P N WA 784 with 4 position connector attached to VP 6124 UPS charger place molex connector through the hole on the supply and connect the charger to the input connector on the VP 6124 Power Snap strain relief into place Replace wire access cover on the Remove cover from Battery Backup Push cable labeled Valcom P N WA 783 with 2 connector through the hole on the Manuals Online enclosure and snap strain relief into Attach connector from VP 6124 UPS to battery Replace access cover Plug power cord from VP 6124 VP 6124 E into outlet Turn ON circuit breaker on Battery Backup a power failure occurs the charger beeps to personnel that the supply is operating on the and there is a 1.5 hour run time available at amp full load Pressing the white button will mute beeping are three 3 LEDs located on the charger the charger is connected to the power supply the green LED signifying the power supply and charger on line and the batteries are charging the red LED illuminates this denotes that the have dropped below 20 volts and the UPS into low voltage shutdown to protect the from damage This disconnects the load red LED will turn off and batteries reconnect power returns and the batteries are charged 25V the battery test button illuminates the yellow if the battery is above 24 volts signifies a good The charger will charge the batteries to volts in a 14 hour period assuming completely batteries must be replaced every five years To reduce the risk of fire or injury persons read and follow these Supplied with four 4 Union Type MX12070 Use only Union Type MX12070 Do not dispose of the batteries in a fire The cell explode Check with local codes for possible disposal instructions Do not open or mutilate the batteries Released is corrosive and may cause damage to eyes or skin It may be toxic if swallowed Exercise care in handling batteries in order not to the battery with conducting materials such as bracelets and keys The battery or may overheat and cause burns Do not attempt to recharge the batteries provided this or identified for use with this product batteries may leak corrosive electrolyte or Do not attempt to rejuvenate the batteries with or identified for use with this by heating them Sudden release of the electrolyte may occur causing burns or to eyes or skin When replacing batteries all batteries should be at the same time Mixing fresh and batteries could increase internal cell and rupture the discharged batteries to products employing more than one replaceable primary battery When inserting batteries into this product the polarity or direction must be observed insertion of batteries can cause charging that may result in leakage or explosion to products employing more than one replaceable primary battery Remove the batteries from this product if the will not be used for a long period of time months or more since during this time battery could leak in the product Discard dead batteries as soon as possible since batteries are more likely to leak in a Do not store this product or the batteries provided or identified for use with this product in areas Batteries that are stored a freezer or refrigerator for the purpose of shelf life should be protected from during storage and defrosting should be stabilized at room temperature to use after cold storage The batteries are excluded from the ASSISTANCE trouble is reported verify that the unit is connected and there are no broken leading to this unit Assistance in is available from the factory When you should have a VOM and a telephone test available and be calling from the job site Call 427 3900 and ask for Technical Support or 540 427 6000 for Valcom 24 hour Automated or visit our website at Manuals Online equipment is not field repairable Valcom Inc maintains service facilities in Roanoke VA Should repairs necessary attach a tag to the unit clearly stating company name address phone number contact person and the of the problem Send the unit to and Return Dept Inc Hollins Road VA 24019 5056 other page or amplified assemblies Outputs Supply Ground Battery Ground Battery Page Unit plates are shown for each unit VBB 1424 TO THE VP 6124 VP 6124 E Inc warrants its products to be free from defects in materials and workmanship under conditions of normal use and service a period of one year from the date of shipment The obligation under this warranty shall be limited to the replacement repair or of any such defective device within the warranty period provided that LIMITED WARRANTY by Valcom Inc indicates the validity of the claim defect is not the result of damage misuse or negligence after the original shipment product has not been altered in any way or repaired by others and that factory sealed units are unopened A service plus parts and labor will be applied to units defaced or physically damaged charges for the return of products to Valcom are prepaid units of warranty are subject to a service charge The service charge will cover minor repairs Major repairs will be to additional charges for parts and labor warranty is in lieu of and excludes all other warranties expressed or implied and in no event shall Valcom Inc be for any anticipated profits consequential damages loss of time or other losses incurred by the buyer in connection the purchase operation or use of the product warranty specifically excludes damage incurred in shipment In the event a product is received in damaged condition the should be notified immediately Claims for such damage should be filed with the carrier involved in accordance with the point Inc Industry Avenue VA 24013 540 427 3900 540 427 3517 Canada Corporation Van Kirk Drive 11 and 12 Ontario L7A1A5 905 456 1072 905 456 2269 Manuals Online

Related Files