Wheelock AHWP horns and horn strobes CSFM listing 0785-0131
File Preview
Click below to download for free
Click below to download for free
File Data
Name | wheelock-ahwp-horns-and-horn-strobes-csfm-listing-0785-0131-4807192356.pdf |
---|---|
Type | |
Size | 735.21 KB |
Downloads |
Text Preview
LISTING No DEPARTMENT OF FORESTRY FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL ENGINEERING BUILDING MATERIALS LISTING PROGRAM SERVICE 1 of 2 FIRE ALARM DEVICES FOR THE HEARING IMPAIRED Wheelock Inc 7246 16th St E Ste 105 Sarasota FL 34243 Thomas Conover 941 487 2336 thomaslconover eaton com AS 1215 2415 1230 2430 121575 241575 2475 and 24110 audible strobes the hearing impaired followed by any three alpha numeric characters indicating lens lettering and color AS 1215W 2415W 1230W 2430W 121575W 241575W 2475W and 24110W for the hearing impaired followed by any three alpha numeric characters lens orientation lettering and color These units with suffix W are for wall mount Models AS 121575W and AS 241575W lens color may be white red blue green or AS 2415C 2430C 2475C and 24100C audible strobes for the hearing impaired by two alpha numeric characters indicating lens lettering orientation and color units are intended for ceiling mount only AH 12 24 AH 12WP 24WP audible appliances no strobe followed by an alpha or character indicating product color AS 24MCW and AS 24MCC audible strobe followed by any two alpha or numeric indicating lettering and product color Lens color may be white red blue green amber ASWP 2475W and ASWP 2475C audible strobe with integral private mode visual signaling for non hearing impaired applications Lens color may be red blue green and amber Both models are suitable for outdoor use when mounted the Model WPBB back box AS 24MCWH AS 24MCCH ASWP 24MCWH and ASWP 24MCCH for the hearing impaired followed by two alpha numeric characters indicating lettering and product color Units with suffix CH are for ceiling mount only Units with WH are for wall mount only Lens color may be white red blue green or amber to the listee s data sheet for detailed product description and operational 10 01 07 listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed test results and or other data but does not make an independent verification of any claims This listing is not endorsement or verify correct requirements or installation criteria Refer to listee data sheet installation instructions and or other should not be used of This Issued 01 2021 Expires 30 2022 By CASTILLO M E F P E Engineering Division No 2 of 2 VDC VFWR Rate 60 flashes minute 15 15cd 1575 15 75cd 30 30cd 75 75cd 95 95cd 100 100cd 110 110cd Selectable 15cd 30cd 75cd 110cd Selectable 15cd 30cd 75cd 95cd Selectable 135cd 185cd 65cd 90cd at 40 C Selectable 115cd 177cd 50cd 75cd at 40 C accordance with listee s printed installation instructions applicable codes and ordinances in a manner acceptable to the authority having jurisdiction Models ASWP 2475W AS 24MCW and AS 24MCWH are for wall mount only Models ASWP 24MCCH AS 24MCCH AND AS 24MCC are for ceiling mount only with suffix W or WH are for wall mount only Models with suffix C or CH are for mount only name model number electrical candela rating and UL label as audible and audible visual signaling devices suitable for the hearing impaired when in conjunction with separately listed electrically compatible fire alarm control units For use only except Models AH 12WP AH 24WP ASWP 2475W ASWP 2475C and ASWP 24MCCH audible appliances are suitable for indoor outdoor synchronization Models AS Series must be used with Model SM 12 24 SMX 12 24 or DSMX 12 24 sync control module CSFM Listing No 7300 0785 132 Refer to Installation Instruction Manual for details appliances can generate a distinctive three pulse Temporal Pattern Fire Alarm Signal for total evacuation in accordance with NFPA 72 2002 Edition AH 12 AH 24 12WP and 24WP audible devices are not suitable for the hearing applications 10 01 07 listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed test results and or other data but does not make an independent verification of any claims This listing is not endorsement or verify correct requirements or installation criteria Refer to listee data sheet installation instructions and or other should not be used of This Issued 01 2021 Expires 30 2022 By CASTILLO M E F P E Engineering Division