Wheelock AMT horn installation sheet P8263

File Preview
File Preview
Click below to download for free

File Data

Name wheelock-amt-horn-installation-sheet-p8263-4569178302.pdf
Type PDF
Size 773.97 KB
Downloads

Text Preview

Branchport Avenue Branch NJ 07740 631 2148 USA 397 5777 CANADA Thank you for using our products INSTALLATION INSTRUCTIONS MULTITONE APPLIANCES this product according to this instruction manual Please keep this instruction manual for future reference Multitone Appliances are UL Listed under Standard 464 for Audible Signal Appliances for Fire Protective Service and for General Signaling Service are also ULC Listed under Standard CAN ULC S525 07 for Audible Signal Appliances for Fire Alarm Systems They are listed for both indoor and use with the backboxes specified in these instructions See Mounting Options A B C D E F G Cooper Notification AMT Appliances are multitone alarm appliances with separate input terminals for each sound They are the ideal choice for Halon Protection Systems and emergency systems where distinctive multiple alarm conditions are required Eight groups of three self prioritized sound outputs are provided with electrically isolated input terminals for each sound see Table 2 and 5 for sound selections Sound output can be field set to provide either HI dBA or STANDARD STD dBA sound output level AMT Multitone Appliances can be field set for either 12VDC or 24VDC operation and are for use with either filtered or unfiltered Full Wave Rectified FWF input voltage All inputs are polarized for compatibility with standard reverse of circuit wiring by Fire Alarm Control Panel FACP All CAUTIONS and WARNINGS are identified by the symbol All warnings are printed in bold capital letters PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE USING THIS PRODUCT FAILURE TO COMPLY WITH ANY OF FOLLOWING INSTRUCTIONS CAUTIONS AND WARNINGS COULD RESULT IN IMPROPER APPLICATION INSTALLATION AND OR OF THESE PRODUCTS IN AN EMERGENCY SITUATION WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY DEATH TO YOU AND OR OTHERS All Canadian installations should be in accordance with the Canadian Standard for the Installation of Fire Alarm Systems CAN ULC S524 and Canadian Electrical Code Part 1 Final acceptance is subject to authorities having jurisdiction THE AMT MULTITONE APPLIANCES MUST BE FIELD SET TO THE DESIRED INPUT VOLTAGE dBA SOUND OUTPUT LEVEL ALARM TONE BEFORE THEY ARE INSTALLED THIS IS DONE BY PROPERLY INSERTING A JUMPER PLUG AND ADJUSTING A FOUR SWITCH IN ACCORDANCE WITH THESE INSTRUCTIONS INCORRECT SETTINGS WILL RESULT IN IMPROPER PERFORMANCE MAY DAMAGE THE PRODUCT WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND OR 1 dBA Ratings for AMT Multitone Signal Time Horn Horn ANSI S3.41 Temporal Pattern Tone ANSI S3.41 Temporal Pattern Whoop Chimes Anechoic at 10 Feet per S525 07 Nominal Voltage Reverberant dBA 10 Feet Per UL 464 Minimum Voltage Nominal Voltage For ULC applications only Code 3 Horn and Code 3 Tone are required to meet the ULC minimum of 85 dBA and the audible signal temporal mandated by the National Building Code of Canada 2015 Cooper Wheelock Inc dba Cooper Notification All rights reserved F 1 of 6 Time Horn 3 Horn 3 Tone Whoop Chime 2 Current Ratings for AMT Multitone Audible Appliances Horn Continuous Hz Modulated 0.07 Sec ON Repeat 0.25 Sec ON 0.25 Sec OFF Repeat ANSI S3.41 Temporal Pattern Hz ANSI S3.41 Temporal Pattern Sweep 4.0 Sec ON 0.5 Sec OFF Repeat Sweep 1.0 Sec ON Repeat Hz 0.25 Sec ON Alternate 1.0 Sec Decay Repeat RMS Current 0.210 0.117 0.210 0.210 0.168 0.182 0.177 0.131 0.090 3 ULC Directional Characteristics 35 degrees left 35 degrees right 55 degrees left 55 degrees right 35 degrees upward 35 degrees downward 65 degrees upward 55 degrees downward CHECK THE MINIMUM AND MAXIMUM OUTPUT OF THE POWER SUPPLY AND STANDBY BATTERY AND SUBSTRACT THE DROP FROM THE CIRCUIT WIRING RESISTANCE TO DETERMINE THE APPLIED VOLTAGE TO THE SIGNALING APPLIANCE FOR UL ULC APPLIANCES THESE APPLIANCES WERE TESTED TO THE OPERATING VOLTAGE LIMITS OF 16 33 VOLTS FOR APPLICATIONS AND 8.0 17.5 VOLTS FOR 12V APPLICATIONS USING FILTERED DC OR UNFILTERED FULL WAVE RECTIFIED FWR NOT APPLY 80 AND 110 OF THESE VOLTAGE VALUES FOR SYSTEM OEPRATION MAKE SURE THAT THE TOTAL RMS CURRENT REQUIRED BY ALL APPLIANCES THAT ARE CONNECTED TO THE SYSTEM AND SECONDARY POWER SOURCES NAC CIRCUITS OR WHEELOCK POWER SUPPLIES DO NOT EXCEED THE POWER RATED CAPACITY OR THE CURRENT RATINGS OF ANY FUSES ON THE CIRCUITS TO WHICH THESE APPLIANCES ARE WIRED POWER SOURCES OR EXCEEDING FUSE RATINGS COULD RESULT IN LOSS OF POWER AND FAILURE TO ALERT DURING AN EMERGENCY WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND OR calculating the total currents Use Table 2 to determine the highest value of Current for an individual AMT across the expected operating range of the AMT then multiply these values by the total number of AMT be sure to add the currents for any other appliances powered by same source and include any required safety factors the peak current exceeds the power supplies peak capacity the output voltage provided by the power supplies may drop below the listed voltage of the appliances connected to the supply and the voltage may not recover in some types of power supplies For example an auxiliary power that lacks filtering at its output stage either via lack of capacitance and or lack of battery backup across the output may exhibit this characteristic AMT Multitone audible appliances produce a brief inrush current that lasts for just 2 microseconds but can reach a peak value of 8.0 Amps 11.2 for FWR input MULTITONE SETTINGS Jumper Plug DP1 and Switch SW1 of the AMT Multitone Appliances shown in Figure 1 are used to set the input voltage dBA sound output level alarm tone The factory settings are shown below Read these instructions carefully before changing any of these factory settings 1 Board Layout Showing Location Jumper Plug DP1 and Switch SW1 HERE FOR 0 HERE FOR 1 1 2 3 Factory Settings are DP1 SET ON 24 dBA SW1 POS 1 1 1 PRI 1 HORN TONE 2 PRI 2 BELL TONE 3 PRI 3 SIREN TONE SW1 POS 2 3 4 1 1 1 F 2 of 6 1 desired input voltage and dBA sound output level as follows Refer to Figures 2 and 3 Multitone Appliances are field set for input voltage and dBA sound output level by inserting a Jumper Plug DP1 and adjusting a four position SW1 as shown in Table 4 and Figures 2 and 3 Use DP1 to select the desired voltage and SW1 Position 1 to select the dBA sound output level 4 Input Voltage and dBA Sound Output Level Settings and SW1 Settings Voltage and Decibel Level 24 VDC HIGH dBA 24 VDC STD dBA 12 VDC HIGH dBA 12 VDC STD dBA DP1 on 24 set SW1 POS 1 on 1 DP1 on 24 set SW1 POS 1 on 0 DP1 on 12 set SW1 POS 1 on 1 DP1 on 24 set SW1 POS 1 on 1 Setting HERE FOR 1 HERE FOR 0 A SMALL SCREWDRIVER TO THE SWITCH POSITION 2 Plug DP1 Settings 3 SW1 Settings SET ON 12 PLUG SET ON

Related Files