Wheelock Eluxa colored lens strobes data sheet

File Preview
File Preview
Click below to download for free

File Data

Name wheelock-eluxa-colored-lens-strobes-data-sheet-9867203154.pdf
Type PDF
Size 1022.71 KB
Downloads

Text Preview

Technical Data TD450160EN colored lens strobes Wheelock Eluxa colored lens strobes by Eaton feature an power saving LED technology in a sleek modern enclosure that will provide high energy efficiency and aesthetically pleasing low profile design that will blend with building interior d With a full range of candela settings 1 device the Eluxa ELST colored lens appliances are ideal for wall and ceiling mount mass notification and emergency applications efficiency LED technology high energy efficient technology leads the industry in lowest draw across the full candela range which reduces overall consumption and costs in fire alarm systems As the first appliances in the industry to utilize LED as the light this breakthrough and patented optical design resulting in efficiency enables material and system cost savings for a greater number of appliances on the notification circuit and fewer power supplies All strobe models six candela settings Amber lens candela settings include 30 75 110 135 185 cd for wall models and 15 30 75 110 177 cd for ceiling models Blue candela settings include 5 10 30 40 50 cd for wall models and 5 12 30 40 50 65 cd for models profile design and rich feature set the industry smallest footprint the Eluxa strobes are pleasing to building owners as the low profile design not detract from the interior decor Eluxa is feature rich with candela settings in 1 device pre wire pre test via mounting plate hinged feature for ease of installation single gang design wall and no tools needed for setting changes These products suitable for indoor wall and ceiling mount applications The ELST are 24V operation and synchronization Eluxa strobes meet the 20 millisecond light pulse duration of the 2016 edition of NFPA 72 By meeting this latest xenon and LED devices can now be in the same field view Eluxa colored lens strobes are listed under UL Standards for fire alarm and signaling and 1971 for light distribution ULC listed under CAN ULC S526 Visual Signal Appliances appliances are Restriction of Hazardous Substances RoHS and contain no mercury or other hazardous substances addition the Eluxa product line has been UL ULC listed as with all Fire Alarm Control Panels FACP and accessories have been determined to be compatible with Exceder LED3 and RSS strobe based products including the RSS CH E EH ST HS MT S8 SA STH and Z Series The listing also includes ability to install the Eluxa strobes in the same notification zone field of view with any Wheelock RSS and Exceder LED3 strobe Effective March 2022 ELST A ELST BELSTC A ELSTC Bfirealarmresources com 1 Wall strobe 1 Wall strobe 2 Ceiling strobe Data TD450160EN March 2022 Energy Efficient runs Low Profile Design Patented LED technology provides industry lowest current Fewer power supplies required smaller wire gage reduced One of the smallest most compact single gang designs Sleek modern aesthetics with no visible mounting screws Amber and blue lens and special lettering models are available 6 Field selectable settings in 1 device Amber Lens Wall 15 30 75 110 135 185 cd Amber Lens Ceiling 15 30 75 110 150 177 cd Blue Lens Wall 5 10 20 30 40 50 cd Blue Lens Ceiling 5 12 30 40 50 65 cd Easy to Install Mounting plate included with all models Convenient capture allows installers to easily hold the device while fastening single mount screw in place Pre wire pre test capability to check for wiring and ground prior to appliance installation Finger slide switches No tools needed for changes screw terminals using 12 to 18 wires Mounting Options include Eluxa ELSBB any single gang and to 4 square with adapter kit for wall models Exceder LSPKBB C backboxes and 4 square 1 1 2 or 2 for ceiling models Strobe Synchronization Components Meet synchronizing standards with Wheelock DSM Sync Power Supplies or SAFEPATH products Ability to mix xenon and LED strobes in the same field of view Compliance Applications NFPA 72 2016 20 ms flash duration requirements UL 1638 Light output meets UL 1971 ULC S526 California State Fire Marshal CSFM Designed for effective alerting of employees or personnel in industrial military or government applications the strobes are ideal for Mass Notification and Emergency read these specifications and associated installation before using specifying or installing this product Visit Eaton for current installation instructions Notes Strobes are designed to flash at 1 flash per second minimum over Voltage Range Note that NFPA 72 specifies a rate of 1 to 2 flashes per second and ADA Guidelines specify flash rate of 1 to 3 flashes per second All candela ratings represent minimum effective Strobe intensity on UL 1971 colored lens strobesEATON www eaton comfirealarmresources com Data TD450160EN March 2022 1 Strobe Ratings lens Voltage VDC Max Current a Max Current a lens Voltage VDC 2 Specification Ordering Information Candela Color w DSM or Power Supplies LED Backbox LED Backbox LED Backbox LED Backbox Lettering Lettering Lettering Lettering Lettering Lettering Lettering Lettering or white textured UV stabilized colored impregnated engineered plastic Exceeds 94V 0 UL flammability rating 0.35 lbs Ceiling 0.55 lbs Emitting Diode LED in a rugged Lexan lens Amber and blue lens models 4.79 x 2.76 W x 1.18 D Trimplate 5.25 H x 4.58 W x 0.32 D Ceiling 6.27 Diameter x 1.69 D Temperature 32 to 122 0 to 50 and maximum humidity of 93 plate included with all models ELST are for wall mount applications only Wall mounting Single gang backboxes or to 4 square with adapter kit ELSTC are for ceiling mount applications only Ceiling mounting backboxes or to 4 square 1 1 2 or 2 1 8 through 18 AWG VDC VFWR 16 33 VDC VFWR 1638 Light output meets UL 1971 Amber lens Selectable 15 30 75 110 135 185 candela output for wall models 15 30 75 110 150 177 candela output for ceiling models Blue lens Selectable 5 10 20 30 40 50 cd for models and 5 12 30 40 50 65 cd for ceiling models are designed to flash at 1 flash per second can be synchronized with Wheelock DSM Sync Modules PS Power Supplies or SAFEPATH products using patented sync protocol RMS current ratings are per UL maximum RMS method UL max current rating is the maximum RMS current within the listed voltage range 16 33v for 24v units For the UL max current is usually at the minimum listed voltage 16v for 24v units For audibles the max current is usua

Related Files