Wheelock ET80-24MCW speaker strobe install sheet P84506

File Preview
File Preview
Click below to download for free

File Data

Name wheelock-et80-24mcw-speaker-strobe-install-sheet-p84506-9285043617.pdf
Type PDF
Size 820.09 KB
Downloads

Text Preview

Branchport Avenue Branch NJ 07740 631 2148 Thank you for using our products ET80 24MCW VANDAL RESISTANT SPEAKER STROBE INSTRUCTIONS this product according to this instruction manual Please keep this instruction manual for future reference Series ET80 24MCW Low Profile Vandal Resistant Speaker Strobe is UL Listed under Standard 1971 for Signaling Devices for the Hearing Impaired for fire protection service The ET80 24MCW is designed for multiple power requirements with high dBA output at each power tap and offer a choice of field taps 1 8W to 8W for either 25.0VRMS or 70.0VRMS audio systems The low profile design incorporates a high efficiency speaker for maximum output at power across a frequency range of 400Hz to 4000Hz and features a sealed back construction for extra protection and improved audibility The ET80 Multi Candela provides four selectable light output intensities in one unit and incorporates a speaker mounting plate attached to the speaker for ease of The Low Profile Speaker Strobe can provide a non synchronized strobe appliance when connected directly to a fire alarm control panel FACP or provide synchronized strobe appliance when used in conjunction with a Sync Module SM Dual Sync Module DSM or Wheelock power supplies The strobe uses a xenon with solid state circuitry enclosed in a polycarbonate lens to provide maximum visibility and reliability for effective visible signaling The ET80 24MCW is for indoor use wall mount only with the backboxes specified in these instructions see wiring and mounting information PLEASE READ THESE INSTRUCTIONS CAREFULLY FAILURE TO COMPLY WITH ANY OF THE FOLLOWING CAUTIONS AND WARNINGS COULD RESULT IN IMPROPER APPLICATION CANDELA SETTING INSTALLATION AND OR OF THESE PRODUCTS IN AN EMERGENCY SITUATION WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS OR DEATH TO YOU AND OR OTHERS 1 UL Listed Models and Ratings at 10 Feet Watts strobe will produce 1 flash per second over the Regulated Voltage range meet the required light distribution patterns defined in UL 1971 ET80 24MCW is UL Listed for indoor use with a temperature range of 32 to 120 0 to 49 and maximum humidity of 85 RH The effect of and storage temperatures shall not adversely affect the performance of the appliance when it is stored in the original cartons and is not subjected to or abuse maximum supervision voltage is 33 volts DC range of speakers is 400 4000Hz Always operate audio amplifiers and speakers within their specified ratings Excessive input may distort sound quality and may damage audio Do not exceed 100 of speaker input voltage per UL 1480 Improper input voltage can damage speaker If distortion is heard check for clipping of the appliance with an oscilloscope and reduce the amplifier input level or gain level to eliminate any clipping CANDELA SETTING WILL DETERMINE THE CURRENT DRAW OF THE PRODUCT 2 UL Current Ratings with Strobe Only RMS Current Amps Voltage calculating the total currents use Table 2 to determine the highest value of RMS current for an individual strobe then multiply these values by the total number of Be sure to add the currents for any other appliances including audible signaling appliances powered by the same source and to include any required safety The maximum number of strobes on a single notification appliance circuit shall not exceed 50 These strobes are UL Listed as They are intended to be used with FACPs whose notification circuits are UL Listed as appliances shall not be used on UL Listed Application notification circuits unless the appliances are identified to be compatible in the installation of the FACP or unless the FACP is identified to be compatible in this instruction manual THESE STROBES WERE TESTED TO THE REGULATED VOLTAGE LIMITS OF 16.0 33.0 VOLTS FOR 24V MODELS USING DC OR UNFILTERED FULL WAVE RECTIFIED VOLTAGE DO NOT APPLY VOLTAGE OUTSIDE OF THIS RANGE CHECK THE MINIMUM AND MAXIMUM OUTPUT OF THE POWER SUPPLY AND STANDBY BATTERY AND SUBTRACT THE DROP FROM THE CIRCUIT WIRING RESISTANCE TO DETERMINE THE APPPLIED VOLTAGE TO THE STROBES THE MAXIMUM IMPEDANCE BETWEEN STROBES SHALL NOT EXCEED 35 OHMS Strobes are not designed to be used on coded systems in which the applied voltage is cycled on and off 2005 Wheelock Inc All rights reserved P84506C 1 of 4 MAKE SURE THAT THE TOTAL RMS CURRENT REQUIRED BY ALL APPLIANCES THAT ARE CONNECTED TO THE PRIMARY AND SECONDARY POWER SOURCES NOTIFICATION APPLICIANCE CIRCUITS SM DSM SYNC MODULES OR POWER SUPPLIES DOES NOT EXCEED THE POWER SOURCES RATED CAPACITY OR THE CURRENT RATINGS OF ANY FUSES THE CIRCUITS TO WHICH THESE APPLIANCES ARE WIRED OVERLOADING POWER SOURCES OR EXCEEDING FUSE RATINGS RESULT IN LOSS OF POWER AND FAILURE TO ALERT OCCUPANTS DURING AN EMERGENCY WHICH COULD RESULT IN DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND OR OTHERS AND MOUNTING INFORMATION The following figures A B show the maximum number of field wires conductors that can enter the backbox used with each mounting option If limits are exceeded there may be insufficient space in the backbox to accommodate the field wires and stresses from the wires could damage the product Check the installed product will have sufficient clearance and wiring room prior to installing backboxes and conduit especially if sheathed multiconductor cable or 3 4 fittings are used the limits shown for each mounting option comply with the National Electrical Code NEC Wheelock recommends use of the largest backbox option shown the use of approved stranded field wires whenever possible to provide additional wiring room for easy installation and minimum stress on the product from wiring MOUNTING BACKBOX MOUNTING SQ X 1 1 2 SQ X 1 1 2 RING 8 32 SQ X 2 1 8 BACKBOX 8 32 NUMBER OF CONDUCTORS RING 18 16 14 12 BACKBOX IS COMPATIBLE WITH WIREMOLD AND CONDUIT MOUNTING HOLES ARE FOR SINGLE GANG DOUBLE GANG 4 SQ 3 1 2 4 OCTAGON OR ROUND BACKBOXES NUMBER OF CONDUCTORS 18 AWG 16 AWG 14 AWG 12 Figure 2 1 PRECEDING SPEAKER FIRE ALARM PANEL FACP PRECEDING STROBE OR SYNC MODULE TO NEXT SPEAKER OR END OF LINE RESISTOR EOLR TO NEXT APPLIANCE OR EOLR This model has in out wiring terminals that accept two 12 to American Wire Gauge AWG wires at each screw terminal leads 3 8 inches and connect to screw terminals Break all in out wire runs on supervised circuits to assure of circuit supervision as shown in Figure 2 The shown in the wiring diagrams is for operation of the STROBE COM Refer to Sync Module instruction sheets SM P83123 DSM P83177 or Wheelock power supplies for additional information Connect ground wire to backbox Install signaling appliance to backbox using mounting screws provided CHECK ELECTRICAL RATINGS SPECIFIED IN TABLES 1 AND 2 AS APPROPRIATE TO ENSURE PROPER ELECTRICAL BE SURE THAT SPEAKER WIRING IS CONNECTED TO SPEAKER TERMINALS ONLY AND STROBE WIRING IS CONNECTED TO TERMINALS ONLY CHECK TO INSURE THAT WIRING AT FACP IS CORRECT IMPROPER ELECTRICAL INPUT CAN DAMAGE PRODUCT OR CAUSE IT TO MALFUNCTION WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO AND OR OTHERS 3 Jumper plug is used to select tap 4 Tap Settings Factory setting is 70V which dBA loudness Tap F B C D E F G H Each doubling of rated Watts increases sound output by 3 dBA selectable input terminals are provided o

Related Files