Wheelock Exceder colored lens install sheet ceiling P85066-001A B-size
File Preview
Click below to download for free
Click below to download for free
File Data
Name | wheelock-exceder-colored-lens-install-sheet-ceiling-p85066-001a-b-size-2814739650.pdf |
---|---|
Type | |
Size | 767.05 KB |
Downloads |
Text Preview
273 Branchport Ave Branch N J 07740 631 2148 Thank you for using our products EXCEDER 2 WIRE FIELD SELECTABLE INSTALLATION INSTRUCTIONS APPLIANCES CEILING MOUNT calculating the total currents use Table 2 to determine the highest value of RMS current for an individual appliance then multiply these values by total number of appliances Be sure to add the currents for any other appliances including audible signaling appliances powered by the same and to include any required safety factors The maximum number of strobes on a single notification appliance circuit shall not exceed 50 this product according to this instruction manual Please keep this instruction manual for future reference Cooper Notification Series Exceder Strobe Appliances are designed for easy installation All models are for 12V or 24V operation The appliance in two main parts The universal mounting back plate allows the the ceiling appliance to be mounted to a single gang double gang 4 square octagon or a 3 octagon backbox Two wire appliance wiring is then connected to the mounting back plate This allows a continuity check of the NAC circuit before any appliances are attached It also allows the appliances to be installed after all finish work has been completed The can snap or install the appliances when all other work is complete These appliances carry the same existing compatibility listings as the Wheelock NS RSS and NH products respectively These notification are UL Listed as They are intended to be used with FACPs whose notification circuits are UL Listed as These shall not be used on UL Listed Application notification circuits unless the appliances are identified to be compatible in the instructions of the FACP or unless the FACP is identified to be compatible in this instruction manual THESE APPLIANCES WERE TESTED TO THE REGULATED VOLTAGE LIMITS OF 16.0 33.0 VOLTS FOR 24 VOLT MODELS AND 8.0 VOLTS FOR 12 VOLT MODELS USING FILTERED DC FOR THE 12 VOLT RANGE AND EITHER FILTERED DC OR UNFILTERED DC FOR 24 VOLT RANGE VOLTAGE DO NOT APPLY VOLTAGE OUTSIDE OF THIS RANGE PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE USING THIS PRODUCT FAILURE TO COMPLY WITH ANY OF FOLLOWING INSTRUCTIONS CAUTIONS AND WARNINGS COULD RESULT IN IMPROPER APPLICATION CANDELA SETTING AND OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION WHICH COULD RESULT IN PROPERTY AND SERIOUS INJURY OR DEATH TO YOU AND OR OTHERS CHECK THE MINIMUM AND MAXIMUM OUTPUT OF THE POWER SUPPLY AND STANDBY BATTERY AND SUBTRACT THE VOLTAGE FROM THE CIRCUIT WIRING RESISTANCE TO DETERMINE THE APPLIED VOLTAGE TO THE STROBES THE MAXIMUM WIRE BETWEEN STROBES SHALL NOT EXCEED 35 OHMS Strobes are not designed to be used on coded systems in which the applied voltage is cycled on and off Range Limit VDC UL ULC 1 Models and Settings Draw Table VDC VRMS MAKE SURE THAT THE TOTAL RMS CURRENT REQUIRED BY ALL APPLIANCES THAT ARE CONNECTED TO THE SYSTEM AND SECONDARY POWER SOURCES NOTIFICATION APPLIANCE CIRCUITS SM DSM SYNC MODULES OR COOPER POWER SUPPLIES DOES NOT EXCEED THE POWER SOURCES RATED CAPACITY OR THE CURRENT RATINGS OF ANY ON THE CIRCUITS TO WHICH THESE APPLIANCES ARE WIRED OVERLOADING POWER SOURCES OR EXCEEDING FUSE RATINGS RESULT IN LOSS OF POWER AND FAILURE TO ALERT OCCUPANTS DURING AN EMERGENCY WHICH COULD RESULT IN DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND OR OTHERS UL ULC Range Limit VDC VDC VRMS Draw Table B Blue G Green R Red R red W white Lettering APPLIANCES Notification Exceder Multi Candela Strobes can provide a non synchronized strobe appliance when connected directly to a Fire Alarm Control FACP or provide a synchronized strobe appliance when used in conjunction with an FACP that incorporates the Wheelock sync protocol a Sync Module or the Wheelock Power Supply Exceder series strobes with amber blue green and red lens are UL Listed under Standard Visual Signaling Appliance for Private Mode Emergency General Utility Signaling The amber lens Strobe Appliances also comply with the polar requirements in the UL Standard 1971 Signaling Devices for the Hearing Impaired for indoor Fire Protection Service and NFPA 72 for Notification Systems They are listed for indoor use only All models are designed for use with either filtered DC VDC or unfiltered Full Wave VRMS input voltage All inputs are polarized for compatibility with standard reverse polarity supervision of circuit wiring by an FACP These are for 12V or 24V operation Strobe devices for 12V are only approved by UL to be set at 15cd and only to be powered by DC not FWR DRAW 2A STC B G R Strobe Current Draw Amps Candela Settings cd 0.163 0.182 0.205 0.253 0.223 0.256 0.328 0.372 Volts Volts 2B STC A Strobe Current Draw Amps Candela Settings cd Volts Volts Candela setting and voltage will determine the current draw of the product 2010 Cooper Wheelock Inc dba Cooper Notification All rights reserved AND MOUNTING BASE PRECEDING FACP OR MODULE NEXT APPLIANCE END OF LINE EOLR 1 2 AND MOUNTING SETTINGS These units are factory set for the most common application of 15cd SELECTION All strobe appliances have in out wiring terminals that two 12 to 18 American Wire Gauge AWG at each screw terminal Strip leads 3 8 inches connect to screw terminals Break all in out wire runs on supervised circuits to integrity of circuit supervision as shown in 1 The polarity shown in the wiring diagrams is the operation of the appliances The polarity is by the FACP during supervision 3 Selector Switch Candela factory settings are shown in above illustrations WINDOW A 1 of 4 Check that the installed product will have sufficient clearance and wiring room prior to installing backboxes and conduit especially if multiconductor cable or 3 4 conduit fittings are used the limits shown for each mounting option comply with the National Electrical Code NEC Cooper Notification recommends use of the largest option shown and the use of approved stranded field wires whenever possible to provide additional wiring room for easy installation and stress on the product from wiring DO NOT OVER TIGHTEN MOUNTING SCREWS EXCESSIVE TORQUE CAN DISTORT THE BASE AND MAY AFFECT OPTION Install mounting plate as shown in Figure 4 to a single gang double gang 4 square or octagon backbox with the provided pan head screws 4 Installation Connect field wiring per Figures 1 and 2 Dress wires back into backbox While performing wiring continuity check leave terminal cover in place Remove terminal cover before snapping or installing the appliance into the mounting plate per Figure 4 Important Device only has one mounting orientation Match the top of the base to the top of the device Secure screw at the top of the device This is required To remove the appliance disengage screw slide appliance up and then pull appliance away from mounting plate WHEN INSTALLING STROBES IN AN OPEN OFFICE OR OTHER AREAS CONTAINING PARTITIONS OR OTHER VIEWING SPECIAL ATTENTION SHOULD BE GIVEN TO THE LOCATION OF THE STROBES SO THAT THEIR OPERAT