Wheelock manual pull stations data sheet

File Preview
File Preview
Click below to download for free

File Data

Name wheelock-manual-pull-stations-data-sheet-9231570684.pdf
Type PDF
Size 773.75 KB
Downloads

Text Preview

Technical Data TD450082EN pull stations MPS non coded manual pull stations are constructed of die cast metal for long lasting performance and may mounted on a single gang backbox in either single or dual action configurations for indoor or use with SPST contacts and terminal strip connections normally open contact will close when the pull station is and is rated for 30 VDC 1 amp and or 120 VAC 1 amp contacts are gold plated to avoid the risk of corrosion single action explosion proof model MPS 400X is UL Listed Factory Mutual approved for use in Class I Division I Groups B and D Class II Groups E F and G and Class III hazardous It also has a marine rating and is approved for applications MPS Pull Stations are NEMA 3R listed mounted to the MPS WP weatherproof back box models are painted red with raised white lettering and a locking to prevent unauthorized reset November 2016 Supersedes June 2011Wheelock MPS Pull Stationsfirealarmresources com Series MPS is operated by pulling the handle on the front of the as far down as it will go at which point the handle locks into and is easily visible from up to 50 feet The handle is reset opening the station with a key placing the handle in the normal position and relocking the station dual action models not shown the push bar rotates inward the Pull handle to be grasped in a one handed motion Data TD450082EN November 2016 benefits Approvals include UL Standard Factory Mutual FM California Fire Marshal CSFM and New York City MEA Single or dual action Key reset Terminal strip connections Corrosion resistant gold plated SPST contacts Mounts on single gang backbox Surface and weatherproof backboxes available Plastic breakrod High gloss red enamel finish with raised white lettering read these specifications and associated installation before using specifying or installing this product Eaton com massnotification for current installation instructions 1 SptcificaoiNns and Nrdtring infNrmaoiNn Code Number a Consult Customer Service for availability single action terminals key reset double action terminals key reset proof single action key reset surface backbox backbox with gasket assembly acrylic breakrods dozen MPS WP MPS WP provided and engineers specifications non coded manual pull stations shall be Wheelock MPS single action double action or approved equals They shall be constructed of rugged die cast metal housing with key reset and corrosion resistant gold plated single or double pole single or double throw contacts wiring connections shall be made via a terminal strip and the unit shall mount to a single gang backbox and when weatherproof manual stations are required the backbox shall be the Wheelock MPS WP backbox with gasket assembly MPS pull stations shall be NEMA 3R when mounted to the MPS WP weatherproof back box MPS 400X shall be installed in installations that require explosion proof Marine or NEMA 4X rated initiating devices Temperature rating to 150 dimensions shall be 4 3 4 x 3 1 4 W x 2 1 4 to continuous development of our products specifications and offerings are subject to change without notice in accordance with Cooper Inc dba Eaton standard terms and conditions ENCOURAGE AND SUPPORT NICET CERTIFICATION WARRANTY is a registered trademark All other trademarks are property of their respective owners Eaton1000 Eaton BoulevardCleveland OH 44122United StatesEaton comEatonLife safety mass notification solutions273 Branchport Ave Long Branch NJ 07740www eaton com massnotification 2016 EatonAll Rights ReservedPrinted in USAPublication No TD450082ENNovember 2016Wheelock MPS Pull Stationsfirealarmresources com

Related Files