Wheelock NPS push button install sheet P84249
File Preview
Click below to download for free
Click below to download for free
File Data
Name | wheelock-nps-push-button-install-sheet-p84249-9405317682.pdf |
---|---|
Type | |
Size | 644.26 KB |
Downloads |
Text Preview
Branchport Avenue Branch NJ 07740 631 2148 Thank you for using our products INSTRUCTIONS STATION this product according to this instruction manual Please keep this instruction manual for future reference SERIES NPS Push Stations NPS for applications that need Normally Open or Normally Closed contacts The NPS can be used for activation of SAFEPATH and SAFEPATH4 Voice Evacuation Systems prerecorded messages The NPS can also be used to activate a message in the event of an emergency or for alerting All CAUTIONS and WARNINGS are identified by the symbol Push Stations with the suffix code with the wording have not been tested to any UL Standard All warnings are printed in bold capital letters PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE USING THIS PRODUCT FAILURE COMPLY WITH ANY OF THE FOLLOWING INSTRUCTIONS CAUTIONS AND WARNINGS COULD RESULT IN APPLICATION INSTALLATION AND OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU OTHERS INFORMATION 1 Terminal Block terminals accept 2 two 12 to 18 American Wire Gauge AWG 1 AMP 3 AMPS DO NOT USE THE SERIES NPS PUSH STATIONS IN INSTALLATIONS WHERE TEMPERATURES FALL OUTSIDE OF THE UL LISTED TEMPERATURE 0 C 32 F TO 49 C 120 F RANGE AS DAMAGE TO FAILURE MAY RESULT FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS OR TO SUBSTITUTE ELECTRICAL CONDUIT FITTINGS THAT DO NO COMPLY WITH CURRENT PRACTICES ADAPTED BY NEC NFPA AND CODES MAY RESULT IN LOSS OF PROTECTION FROM WATER OR DUST IN ALL AREAS WHERE FREQUENT WASH DOWNS OCCUR STAND OFF BLOCK MUST BE 2015 Cooper Wheelock Inc dba Cooper Notification All rights reserved G 1 of 3 in five colors Red Green Yellow White Blue wording available faceplate steel backplate 2017 listed switch assembly Compliant INSTRUCTIONS to single gang electrical backbox or replaceable Normally Open NO Normally Closed NC single pole single throw plated contact blocks rated for 3 amps 600 or 1 amp 250 VDC be reset by depressing the Push button and clockwise a 1 4 turn 5 H x 3 1 4 W x 1 1 2 D RECOMMENDS THE USE OF THIS NOT PROVIDED FOR SWITCH CLEARANCE STANDARD SINGLE GANG BOXES ASSEMBLY 6 32 X 1 SCREWS HOUSING YELLOW WHITE OR RED LABEL BUTTON SCREW 2 Overview of Assembly To provide adequate clearance for installation one of the following is recommended Safety Tech Inc STI 102722 or Raco 660 W 1 2 K O and Raco 653 Extension Ring Also Raco 696 Masonry Box Additional Normally Open NPS NO 0523 or Normally Closed NPS NC 0524 can be purchased separately 3 Back view of Push Station G 2 of 3 PROCEDURES this mounting procedure to position the field wires in the backbox so that they use minimum space and produce minimum stress the product This is especially important for stiff heavy gauge wires and wire with thick insulation or sheathing Strip 1 4 of wire insulation and insert in terminal block then using a Phillips screwdriver turn screws clockwise until tightened Remove screw on bottom of Push Station unit with Allen Wrench included in hardware package Carefully push terminal block into backplate of Push Station until it snaps in securely Carefully press Push Station into backbox then screw Push Station into backbox using the 2 6 32 screws provided in hardware Reattach Push Station to unit and secure with screw provided using Allen Wrench NOTES Check that the installed product will have sufficient clearance and wiring room prior to installing backboxes and especially if sheathed multiconductor cable or 3 4 conduit fittings are used Conduit entrances to the backbox should be selected to provide sufficient wiring clearance for the installed product When terminating field wires do not use more lead length than required Excess lead length could result in insufficient wiring for the signaling appliance Do not pass additional wires used for other than the signaling appliance through the backbox Such additional wires could result insufficient wiring space for the signaling appliance MATERIAL EXTRAPOLATED FROM THIS DOCUMENT OR FROM WHEELOCK MANUALS OR OTHER DESCRIBING THE PRODUCT FOR USE IN PROMOTIONAL OR ADVERTISING CLAIMS OR FOR OTHER USE INCLUDING DESCRIPTION OF THE PRODUCT APPLICATION OPERATION INSTALLATION TESTING IS USED AT THE SOLE RISK OF THE USER AND WHEELOCK WILL NOT HAVE ANY LIABILITY SUCH USE G 3 of 3