Technical Data TD450003EN NAC Power Supply Wheelock POWERPATH PS 8 LP by Eaton is a supervised power supply battery charger in a low profile cabinet that is for supervision and expanded power driving capability of fire Notification Appliance Circuits NAC The PS 8 LP is filtered regulated and provides 8 amps of power distributed across 4 power supplies may be connected to any 12V or 24V FWR DC Fire Alarm Control Panel FACP by using a NAC or a Primary applications include NAC expansion supports ADA and auxiliary power to support system accessories unit provides filtered and regulated 24VDC up to four 4 Class two 2 Class or two 2 Class and one 1 Class Appliance Circuits With the optional plug in PS EXP the unit supports 8 Class or 4 Class Notification Circuits Additionally an auxiliary power output of 2.5 disconnected upon AC power loss or an alarm condition or to 0.240 A of constant power on the PS 8 LP Wheelock power supplies can accommodate 7 AH batteries its lockable chassis Using an external battery cabinet it can up to 33 AH batteries pending UL testing Two FACP NAC or two contact initiating circuits can be connected to inputs These inputs can then be directed to control supervision power delivery to any combination of the four 4 outputs Each is rated at 3.0 Amps Class or Class and can be to generate a steady or Code 3 temporal horn sound a strobe output under alarm condition Total load for PS 8 LP circuits must not exceed the power supplies rated output power supplies under non alarm condition provide independent for Class and Class FACP NAC circuits In event of circuit trouble the FACP will be notified via the steered input IN1 or IN2 In addition there are two of trouble reporting terminals one used for AC power loss and the other for all troubles The AC power loss reporting the common trouble terminals and on IN1 or IN2 can be delayed either 30 seconds or 170 minutes The AC power loss terminals always report the trouble within 1 second after loss of AC PS 8 LP power supplies are UL listed under UL Standard 864 Edition to be used with any 24 volt listed regulated notification They include the capability to synchronize Wheelock and horns and to silence the horn signal when horn strobes operating on two wires October 2017Supersedes December 2015 PS 8 LPfirealarmresources com 120VAC 50 60Hz 4.25 Amps and 5.32 Amps Operating Power Automatic switch over to standby batteries when AC fails Supports sealed lead acid or gel type batteries NAC Power Supply Power Not battery dependent Fused battery protection Thermal and short circuit protection with auto reset Approvals Include UL Standard 864 UL 1481 Supports 7AH batteries Compliance Compliant with NFPA 72 Factory Mutual FM Operating Modes refer to Installation Manual Normal Mode Provides constant 24 VDC output upon initiation a voltage to input IN1 or IN2 or by a contact opening on or DRY2 The unit returns to standby mode when the is deactivated Wheelock Sync Mode Provides signals for synchronization of Wheelock audible and strobe notification appliances can also be silenced in this mode while the strobes to flash Sync Mode Accepts a synchronization signal on the to provide a coded output or synchronized output This may come from a FACP another POWERPATH or a DSM synchronization module Caution Do not use on coded output circuits True Input Follower Mode Accepts a coded signal on the input provide a coded output with the same timing as the input signal may come from a FACP another POWERPATH or coded source Caution Do not use strobes on coded circuits Temporal Mode Codes the output voltage in a code 3 temporal to drive audible appliances such as horns bells or Caution Do not use strobes on coded output circuits Data TD450003EN October 2017 Low Profile Alarm 240VAC 60Hz 3.22 Amps Operating Power in Alarm 24VDC Battery Backup Connection Two 2 12V or 24V NAC Initiating Circuits 8 33V at 5mA FWR or DC Two 2 Contact initiating Circuits Accepts two 2 Class or two 2 Class circuit inputs Built in battery charger for sealed lead acid or gel type batteries Outputs NAC outputs are 24VDC 3.0 Amps each power limited 8 Amps on PS 8 LP total alarm current Capable of four 4 Class circuits Capable of two 2 Class circuits Capable of one 1 Class circuit and two 2 Class Capable of 8 Class or four 4 Class circuits with PS EXP module Temporal Code 3 constant voltage output Wheelock Sync or True input to output follower mode Built in Wheelock synchronization mode that can be fed to any all of the output circuits and output can be synchronized with SYNC DSM 2nd POWERPATH or FACP with synchronization is required Audible silence capability Filtered and electronically regulated output 2.5 Amp auxiliary power limited output with reset capability upon AC loss or alarm Automatic reset 30 seconds AC power returns or the alarm condition is over or 0.240 PS 8 LP of auxiliary power limited output which remains during AC loss or an alarm condition when configured for 24 battery backup Supervision or IN2 Compatible with 12V or 24V FWR or DC FACP Signaling appliance circuits are supervised and steered to either 10K Ohm 1 Watt Wheelock Model 100651 PSEOL End of Resistor EOLR for supervision of all outputs 37 distinguishable trouble diagnostics AC loss trouble reported over a separate set of contacts delay 1 second All troubles are reported over the common trouble contacts AC can have a delay of 30 seconds or 170 minutes Automatic switchover to standby battery when AC fails Thermal and short circuit protection with auto reset and output status LED indicators AC fail supervision Battery presence and low battery supervision Ground Fault Detection with diagnostics to indicate which fault is on Latching LEDs for NAC trouble annunciation and Diagnostic LEDs latching can be disabled www eaton comfirealarmresources com Data TD450003EN October 2017 amp power supply red enclosure 120V amp power supply red enclosure 220V amp power supply black enclosure 120V amp power supply black enclosure 240V amp power supply with preinstalled expansion module red enclosure 120V amp power supply with preinstalled expansion module red enclosure 240V class B or 2 class A expansion module NAC Power Supply 1 Specification Ordering Information 2 Specifications can house up to two 7 AH batteries Circuit voltage range Current 12 VDC Current 24 VDC Circuit 4 Class B or 2 Class A or 1 Class A and Two 2 Class or Class B or 4 Class A optional PS EXP module necessary 11.5lbs Ship 9.4lbs Unit PS EXP 1lb Ship Unit 17 x 13 x 3.5 PS EXP 4.3 x 3.7 x 1 to 33 VDC amps amps VDC up to 3 amps per circuit duty up to 3 Amps per circuit up to 4 Amps maximum per panel Current Current PS 8 LP 120VAC models PS 8 EXP LP 240 VAC models Power Charging Capacity Output Mode Mode Amps Amps to 130 VAC 50 60 Hz 5.32 Amps to 260 VAC 50 60 Hz 3.22 Amps Amp hours 0.750 Amps per hour up to 250 mA during non alarm www eaton comfirealarmresources com Da

Related Files