Wheelock S9100

File Preview
File Preview
Click below to download for free

File Data

Name wheelock-s9100-4150789632.pdf
Type PDF
Size 1022.77 KB
Downloads

Text Preview

Notification NAC POWER SUPPLIES PS 6 and PS 8 Power Supplies are UL Listed under UL 864 9th Edition to be used with any 24 volt Listed notification appliances They include the capability synchronize Wheelock strobes and horns and to silence the signal when horn strobes are operating on two wires Approvals Include UL Standard 864 1481 California State Fire Marshal CSFM Factory Mutual FM Compliant with NFPA 72 120VAC 50 60Hz 4.25 Amps PS 6 8 and 5.32 Amps PS 8 Operating Power in Alarm 240VAC 60Hz 2.42 Amps PS 6E and 3.22 Amps PS 8E Operating Power in Alarm 24VDC Battery Backup Connection Two 2 12V or 24V NAC Initiating Circuits 8 33V at 5mA Two 2 Contact initiating Circuits Accepts two 2 Class or two 2 Class circuit inputs Built in battery charger for sealed lead acid or gel type or DC NAC outputs are 24VDC 3.0 Amps each power limited 8 Amps on PS 8 and 6 Amps on the PS 6 total alarm current continued on next page Wheelock Series PS 6 and PS 8 are 24VDC filtered and supervised remote power supply battery chargers are for supervision and expanded power driving capability of Fire Notification Appliance Circuits The PS 6 provides 6 amps of distributed across 4 outputs while the PS 8 provides 8 Amps 4 output In addition the PS 8 provides additional room in chassis for accessories like an Addressable Control Module with studs Power Supplies may be connected to any 12V or 24V FWR or Fire Alarm Control Panel FACP by using a Notification Appliance NAC or a Contact Primary applications include NAC supports ADA requirements and auxiliary power to system accessories This unit provides filtered and regulated up to four 4 Class two 2 Class or two 2 Class and one 1 Class Notification Appliance Circuits With the plug in PS EXP module the unit supports 8 Class or Class Notification Appliance Circuits Additionally an auxiliary output of 2.5 Amps disconnected upon AC power loss or an condition or up to 0.240 A of constant power on the PS 8 and A of constant power on the PS 6 Wheelock Power Supplies can accommodate 7 or 12 AH batteries its lockable chassis Using an external battery cabinet it can up to 33 AH batteries pending UL testing Two FACP NAC or two contact initiating circuits can be connected to the These inputs can then be directed to control supervision and delivery to any combination of the four 4 outputs Each output rated at 3.0 Amps Class or Class and can be programmed generate a steady or Code 3 Temporal Horn sound and a strobe under alarm condition Total load for the PS 6 and PS 8 NAC must not exceed the power supplies rated output Power Suppliesunder non alarm condition provides independent for Class and Class FACP NAC circuits In the of circuit trouble the FACP will be notified via the POWERPATH input IN1 or IN2 In addition there are two sets of trouble terminals one used for AC power loss reporting and the for all troubles The AC power loss reporting on the common terminals and on IN1 or IN2 can be delayed for either 30 or 170 minutes The AC power loss terminals will always the trouble within 1 second after loss of AC power Capable of four 4 Class circuits Capable of two 2 Class circuits Capable of one 1 Class circuit and two 2 Class circuits Capable of 8 Class or four 4 Class circuits with optional PS EXP module Temporal Code 3 constant voltage output Wheelock Sync output or True input to output follower mode Built in Wheelock synchronization mode that can be fed to any or all of the output circuits Input and output can be synchronized with SYNC mode DSM 2nd POWERPATH or FACP with protocol is required Audible silence capability Filtered and electronically regulated output 2.5 Amp auxiliary power limited output with reset capability Removed upon AC loss or alarm Automatic reset 30 seconds after power returns or the alarm condition is over or 0.075 Amps PS 6 or 0.240 Amps PS 8 of auxiliary power limited output remains on during AC loss or an alarm condition when configured for 24 hour battery backup Compatible with 12V or 24V FWR or DC FACP Signaling appliance circuits are supervised and steered to either IN1 or IN2 10K Ohm 1 Watt Wheelock Model MPEOL End of Line Resistor EOLR for supervision of all outputs 37 distinguishable trouble diagnostics AC loss trouble reported over a separate set of contacts delay of 1 second All troubles are reported over the common trouble contacts AC loss can have a delay of 30 seconds or 170 minutes Automatic switchover to standby battery when AC fails Thermal and short circuit protection with auto reset Input and output status LED indicators AC fail supervision Battery presence and low battery supervision Ground Fault Detection with diagnostics to indicate which circuit fault is on Latching LED for NAC trouble annunciation and Diagnostic trouble LED latching can be disabled Not Battery Dependent Automatic switch over to standby batteries when AC fails Supports sealed lead acid or gel type batteries Fused battery protection Thermal and short circuit protection with auto reset Supports both 7AH or 12AH batteries in the same cabinet Operating Modes refer to Installation Manual Mode Provides constant 24 VDC output upon initiation by a voltage to input IN1 or IN2 or by a contact opening DRY1 or DRY2 The unit returns to standby mode when the input is deactivated Sync Mode Provides signals for synchronization of patented Wheelock audible and strobe notification Audibles can also be silenced in this mode while the strobes continue to flash Sync Mode Accepts a synchronization signal on the input to provide a coded output or synchronized output This signal come from a FACP another POWERPATH or a Wheelock DSM synchronization module Caution Do not use strobes on coded circuits Input Follower Mode Accepts a coded signal on the input to provide a coded output with the same timing as the The signal may come from a FACP another POWERPATH or other coded source Caution Do not use strobes coded output circuits Mode Codes the output voltage in a code 3 temporal pattern to drive audible appliances such as horns or chimes Caution Do not use strobes on coded output circuits and Ordering Information FM Approved Pending Technical for additional on upgrade Voltage Current amp red enclosure amp black enclosure amp red enclosure amp black enclosure amp power supply with preinstalled expansion module amp power supply with preinstalled expansion module class B or 2 class A expansion module upgrade kit for models prior to January 2010 Voltage and Current Number Circuit voltage Range Current 12 VDC Current 24 VDC Circuit 4 Class B or 2 Class A or 1 Class A and Two 2 Class or Class B or 4 Class A PS EXP module necessary duty up to 3 Amps per circuit up to 4 Amps maximum per panel to 33 VDC amps amps Voltage and Current VDC up to 3 amps per curcuit Amps Amps to 130 VAC 50 60 Hz 4.25 Amps to 130 VAC 50 60 Hz 5.32 Amps to 260 VAC 50 60 Hz 2.42 Amps to 260 VAC 50 60 Hz 3.22 Amps

Related Files