Wheelock safepath-csfm-0785-0157
File Preview
Click below to download for free
Click below to download for free
File Data
Name | wheelock-safepath-csfm-0785-0157-5469801372.pdf |
---|---|
Type | |
Size | 735.87 KB |
Downloads |
Text Preview
CALIFORNIA DEPARTMENT OF FORESTRY FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL ENGINEERING BUILDING MATERIALS LISTING PROGRAM SERVICE No 1 of 2 VOICE COMMUNICATION SYSTEMS CONTROL UNITS Wheelock Inc 7246 16th St E Ste 105 Sarasota FL 34243 Thomas Conover 941 487 2336 thomaslconover eaton com SP40S voice evacuation unit Unit does not sense an emergency condition but when from a control unit can provide pre recorded messages and or live voice messaging a local microphone The SP40S also features night ring NR telephone paging TEL and music BGM which are not operational during alarm conditions These features not operate if the system is only powered by a secondary source System components Microphone Battery Enclosure Notification Circuit Interface Module Multi function Facility Communication System Multi function Facility Communication System Multi function Facility Communication System Multi function Facility Communication System 400 Audio Boosters Remote Microphone 4 Remote Microphone Non Fire Application Microphone Expansion Module Paging Splitter Volume Control Module Zone Class B Speaker Audio Splitter Zone Class A 4 Zone Class B Audio Splitter Bracket Enclosure Backbox SP40S D SP40SE D SPB 160 to listee s data sheet for additional detailed product description and operational SPB 80 4 120 VAC 2.4A 240 VAC 1.5A 160W Audio 80 W Audio 24 VDC 4.3A 24 VDC 2A NAC Circuit accordance with listee s printed installation instructions applicable codes ordinances in a manner acceptable to the authority having jurisdiction name model number electrical rating and UL label 11 29 11 gt listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed test results and or other data but does not make an independent verification of any claims This listing is not endorsement or verify correct requirements or installation criteria Refer to listee data sheet installation instructions and or other should not be used of This Issued 01 2021 Expires 30 2022 By CASTILLO M E F P E Engineering Division as voice evacuation unit when used in conjunction with separately listed electrically functionally compatible fire alarm control units Refer to listee Installation Instruction for details telephone paging is not to be used for emergency use No 2 of 2 11 29 11 gt listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed test results and or other data but does not make an independent verification of any claims This listing is not endorsement or verify correct requirements or installation criteria Refer to listee data sheet installation instructions and or other should not be used of This Issued 01 2021 Expires 30 2022 By CASTILLO M E F P E Engineering Division