Wheelock SAFEPATH LOC and remote microphone install sheet P85173

File Preview
File Preview
Click below to download for free

Text Preview

MICROPHONE AND OPERATING CONSOLE AND OPERATION MANUAL Number P85173 Rev B 2012 Cooper Wheelock Inc dba Cooper Notification All rights reserved OPERATING CONSOLEfirealarmresources com you for using our products Use this product according to this instruction manual Please keep this instruction manual for future reference SP4 Remote Microphone and Local Operating Console is designed to be used with the Facility Communications System using the SP40S panel It contains the SafePath SPRM Remote Microphone Module and eight black Push On Push Off buttons which provide a closure to activate the SP40S digital messages in the Push On position These buttons have an LED that illuminates when in the ON A message name plate holder is located above the pushbuttons An optional red mushroom type cutoff pushbutton is available for emergency shutoff Remote Microphone SPRM incorporates a Push To Talk PTT microphone and system status LED indicators The SPRM provides a override for any tone generation digital voice module prerecorded message background music or telephone paging It is equipped a keyed lock that when activated allows the use of the module The key cannot be removed in the ON position The SPRM is fully from the SP40S panel and contains front panel LEDs for remote indications of System Normal System Trouble and Alarm Voice frequency response must be 275 Hz to 6.5 kHz 2.4 dB Power requirements must be 24VDC and are supplied by the Input current for standby mode must be 26mA and 35mA in the alarm mode 20mA Max All Buttons ON Shielded 6 wire cable must used Approvals for the system must include UL Standard 864 UL Standard 1711 FCC Part 15 and CSFM The panel must be OSHA and ADA compliant SP4 LOC is available in two models flush mount and surface mount The flush mount model has a 1 2 inch skirt around the door section the surface mount model door section is flush with the backbox Both models use the same white 3 1 2 inch deep backbox with three 1 2 and 3 4 inch double knockouts one each in the back center and top and bottom of the backbox flush mount door section has exterior dimensions of 15 1 2 inches wide and 16 1 4 inches high The surface mount model has dimensions 14 1 2 inches wide 15 1 2 inches high and 3 1 2 inches deep Both models have a pull slam latch to open the continuous hinged door Both are available in white SP4 LOC can be installed up to 2,000 feet 609.6 meters from the SP40S panel using 14 18 AWG shielded wiring CONVENTIONS manual uses the following notation conventions A POTENTIALLY HAZARDOUS SITUATION THAT IF NOT AVOIDED COULD RESULT IN SERIOUS INJURY OR DEATH TO YOU AND OR OTHERS a potentially hazardous situation that if not avoided could result in minor or moderate injury It may also be used to against unsafe practices ALL ELECTRICAL CIRCUITS AND EQUIPMENT ASSOCIATED WITH INSTALLING THE SP4 LOC IF THE PUSHBUTTON OPTION IS BEING ADDED THE CIRCUIT CAN CONTAIN HIGH VOLTAGE THAT CAN CAUSE INJURY OR DEATH TO THE INSTALLER copies of this manual may be obtained from www coopernotification com in the Technical Support section or from Notification Branchport Ave Branch N J 07740 800 631 2148 732 222 2588 info coopernotification com B 2 of 10 Entry Lock Boards H x W x D Figure 1 x 14 1 2 x 3.5 in Front 15 1 4 x 14 1 2 x 1 8 in Front x 15 1 2 x 1 8 in lbs Surface Mount Flush Mount bottom and back knockouts 1 2 inch 3 4 inch 3 total slam latch with 1 8 inch security indicator installation holes and Pushbutton Temperature to 49 32 to 120 Temperature to 70 4 to 158 Non condensing at 30 86 4 SPECIFICATIONS Switch Rating mA at 24VDC Mushroom Pushbutton at 3 Amps from the SP40S distance from SP40S 2,000 feet using 14 AWG wire American Wire Gauge AWG 6 Conductor cable with overall The shield must be connected only at the SP40S Panel Voltage 24VDC at 20mA Max connected to the Pushbutton Board audio output to SP40S closure to SP40S B 3 of 10 1 Outside Dimensions for the SP4 LOC Front Door B 4 of 10 OPERATING CONSOLE15.50 14.50 16.25 15.25 BACKBOX OUTLINETRIM RING 1 2 PANEL DOORfirealarmresources com with all of the latest applicable codes regulations laws standards and guidelines Remove the FRONT DOOR ASSEMBLY from the backbox by removing the eight 8 nuts holding the assembly in place flush mount only Remove the INNER PANEL ASSEMBLY Figure 2 from the backbox 2 Inner Panel Assembly Mount the backbox assembly See Figure 3 for mounting holes Ensure the assembly is properly orientated All mounting holes are laser cut as knockouts Punch out the holes required for either flush or surface mounting B 5 of 10 3 Mounting Holes for Mounting the Backbox Flush and Surface Connect the conduit fittings to the desired cable knockouts and run the appropriate pushbutton and SPRM wiring into the backbox the optional HVAC pushbutton is installed run the HVAC wiring through a separate conduit away from the pushbutton and microphone wiring Do not use the rear panel knockout This prevents electrical interference and false troubles from on the SP40S the SP4 LOC is being flush mounted and finish work on the location has to be completed stop here and complete the work before and mounting the inner panel and outer door B 6 of 10 MOUNT HOLES 4 FLUSH MOUNT HOLES 8 1 4 x1 2 DOUBLE KNOCKOUT 3 TOP BOTTOM AND BACK 1 2 3 4 firealarmresources com AND WIRING THE INNER PANEL applicable mount and wire the optional HVAC Emergency Shutoff Pushbutton Connect the pushbutton IN wiring to the terminal blocks TB2 and TB3 as shown in Figure 4 SP40S Connect the pushbutton RET TB4 and TB5 wiring to the next LOC IN pushbutton terminal blocks Connect 28V wiring to the terminal blocks as shown in Figure 4 SP40S 28V wiring is needed on the Pushbutton Board to illuminate LEDs when a button is pressed 4 Wiring Diagram Pushbuttons SP4 LOC to SP40S Connect the SPRM to the SP40S Figure 5 shows the proper wiring connections for the SPRM to the SP40S To activate supervision at the SP40S switch the corresponding DIP switch SP40S SW7 positions 1 through 8 to the ON position To eliminate the need for external 10K EOLRs the user can activate on board EOLRs by the DIP switch positions 1 through 8 on the Board of the SP4 LOC shown in Figure 4 Turn the switch ON if the 10K EOLR is needed If the 10K EOLR is not or if it is not the end of line turn the corresponding DIP switch position OFF B 7 of 10 5 Wiring Diagram SPRM to SP40S is power limited Mount the INNER PANEL to the backbox using the four 8 32 truss head screws Mount the FRONT DOOR to the backbox using the eight washers and 8 32 nuts in the locations shown in Figure 8 flush mount 6 shows a diagram of a surface mount FRONT DOOR with a dotted line indicating the trim ring for a flush mount door 6 Front Door Layout B 8 of 10 OPERATINGCONSOLE1 8 SECURITY WIRE HOLESSLAM LATCH 8 32 X 3 4 STUDS 8 ON BACK OF FRONT RING1 2 TRIM RING ON FLUSH MOUNT MODEL FRONT RINGfirealarmresources com INSTRUCTIONS Panel 7 Switch and Jumper Locations on the SP40S for SPRM Operation Set the NAC CC Switch SW6 on the SP40S PC Board to the CC position Figure 7 for switch and jumper locations Set the AUX IN jumper J4 to the 1V position Remove AUX SUP jumper JP4 Energize the SP40S Panel Install the backup batteries Test each pushbutton circuit to insure the SP4 LOC is operational Insert key and turn to the ON position for the controls to function The key is removable only in the OFF position

Related Files