Wheelock Universal Telephone Alerts (UTA) install sheet P82968
File Preview
Click below to download for free
Click below to download for free
File Data
Name | wheelock-universal-telephone-alerts-uta-install-sheet-p82968-5392814706.pdf |
---|---|
Type | |
Size | 658.64 KB |
Downloads |
Text Preview
273 Branchport Ave Branch NJ 07740 631 2148 Thank you for using our products INSTALLATION INSTRUCTIONS TELEPHONE ALERT this product according to this instruction manual Please keep this instruction manual for future reference UTA 1 INFORMATION UTA is a loud attention getting electronic ringer designed for use in noisy locations or for wide area coverage It is FCC and DOC Registered for public telephone network and can be used behind PBX and key systems that use interrupted ring voltages from 40 130V 20 30Hz or 18 or 36 60VDC UTA when used indoors will accommodate a modular plug that mates with an RJ 11C jack USA or a CA 11 jack Canada for ringing voltage operates directly off the telephone ringing voltage with low current drain to minimize line loading offers a choice of four selectable sound patterns horn bell single chime or vibrating chime with a volume control The UTA is equipped with a resistant backbox for optional outdoor use with conduit enclosed wiring INFORMATION installation of this product must conform to the following instructions IF ANY WORDS OR LETTERS APPEAR ON THE PRODUCT INDICATING PARTICULAR USE THE PRODUCT MUST BE USED ONLY IN THE MANNER SO INDICATED FIELD ADJUSTMENT REPAIR OR OF THESE SIGNALS SHOULD NOT BE ATTEMPTED Malfunctioning units should be returned for factory repair or replacement in with Cooper Notification published terms and conditions All CAUTIONS and WARNINGS are identified by the symbol All warnings are printed in bold capital letters The installation of this equipment should only be undertaken by qualified personnel SHUT OFF ALL POWER BEFORE INSTALLING ELECTRICAL SHOCK CAN CAUSE DEATH OR SERIOUS INJURY REGULATIONS equipment complies with Part 68 of the FCC Rules The label affixed to this product contains among other information the FCC Registration and the Ringer Equivalence Number REN for this product This information must be provided to the telephone company if requested REN is used to determine the quantity of devices which you may connect to your telephone line and still have all of those devices ring when telephone number is called In most but not all areas the sum of the REN of all devices connected to one line should not exceed five 5.0 be certain of the number of devices that you may connect to your line contact your local telephone company equipment should not be used on coin telephone lines Connection to party line service is subject to state tariffs trouble is experienced disconnect this equipment from the telephone line to determine if it is causing the malfunction If the equipment is to be malfunctioning its use shall be discontinued until the problem has been corrected the equipment cause harm to the telephone network the telephone company shall if possible notify the customer that temporary of service may be required however where prior written notice is not possible the telephone company may temporarily service without notice if such action is necessary under the circumstances The telephone company may make changes in its facilities equipment and operations procedures where such action is reasonably required in the operation of its business and is inconsistent with the rules and regulations of the Federal Communications Commission CANADA IC REGULATIONS Only applicable for use in Canada Industry Canada IC label identifies certified equipment This certification means that the equipment meets certain telecommunications protective operational and safetey requirements as prescribed in the appropriate Terminal Equipment Technical requirements The Department does not guarantee the equipment will operate to the user satisfaction installing this equipment users should ensure that it is permissible to be connected to the facilities or the local telecommunications The equipment must also be installed using an acceptable method of connection The customer should be aware that compliance with above conditions may not prevent degradation of service in some situations to certified equipment should be coordinated by a representative designated by the supplier Any repairs of alterations made by the user this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment should ensure for their own protection that the electrical ground connections of the power utility telephone lines and internal metallic water system if present are connected together This precaution may be particularly important in rural areas Users should not attempt to make such connections themselves but should contact the appropriate electric inspection authority or as appropriate EQUIVALENCE NUMBER Ringer Equivalence Number REN assigned to each terminal device provides and indication of the maximum number of terminals allowed to be to a telephone interface The termination of an interface may consist of any combination of devices subject only to the requirement that the of the Ringer Equivalence Numbers of all the devices does not exceed 5 2011 Cooper Wheelock Inc dba Cooper Notification All rights reserved K 1 of 4 Chime Chime 1 Sound Output dBA and Current REN at Maximum Volume More 1.6 REN No More 1.4 REN No More 1.25 REN No More 1.25 REN Voltage Range 24VDC 18 30VDC 24VAC 18 30VAC 48VDC 36 60VDC 90VRMS 40 130VRMS 20 30Hz is measured on axis in a non reflective free field test room using fast meter response 2 Sound Output Volume Adjusting Range Chime Chime Chime Chime 3 Tone Description Horn Modulated 0.07 Sec ON Repeat 1.0 Sec Decay Repeat 1.0 Sec Decay 48VDC 4 Duty and Ring Cycle Cycle Ring Cycle ON Time Ring Cycle OFF Time Ring Cycle ON Time Max Sec Sec Sec Max Sec Sec SETTINGS SW1 and SW2 switches of the UTA are used to set input voltage and desired tone as shown in Figure 2 and Table 5 The potentiometer R12 in Figure 2 is used to adjust the volume of sound factory settings are Voltage 90Vrms 20 30Hz SW1 POS 1 set on 0 Horn SW2 POS 1,2,3,4 set on 0,0,1,1 Maximum 5 Input Voltage and Tone Selections Settings 1 1 2 3 4 Chime Chime Chime Chime Chime Chime Chime Chime K 2 of 4 INFORMATION UTA is designed for mounting to walls partitions or posts in both indoor and outdoor applications Refer to Figures 1 2 and 3 mounting wiring and of each model Use 4 conductor modular telephone line cords for ring voltage indoor wiring For outdoor applications use conduit enclosed All models are rated for indoor and outdoor use with a temperature range of 31 to 150 35 to 66 and a maximum humidity of 95 Potentiometer shaft and four screws must be installed first before proceeding with Figure 1 mounting test the signal by temporarily connecting it as shown Place a call into the system to make sure the signal operates properly DO NOT STAND CLOSE TO THE UTA WHEN TESTING OR OPERATING TOO MUCH EXPOSURE AT CLOSE RANGE MAY BE TO YOUR HEARING UTA SH