Autocall Dual Emergency Communication Appliances, Clear Amber Strobes

File Preview
File Preview
Click below to download for free

Text Preview

UL ULC CSFM Listed Addressable Notification Appliances Emergency Communication Appliances Clear Amber Strobes addressed and separately controlled multi candela visible only notification appliance with one amber ALERT and one clear lens FIRE strobe provides Combination unit allows mounting two visible notification appliances at same installation site Multi candela xenon strobes with synchronized 1 Hz flash rate and with programmable from the control panel or jumper selected 15 30 75 or 110 cd Advanced addressable notification controlled by IDNAC SLCs from 4100ES fire alarm control panels with EPS EPS power and 4009 IDNAC Repeaters providing regulated 29 VRMS strobes to operate with lower current even under battery Amber lens with ALERT lettering produces a signal unique from lens fire alarm evacuation strobes for use with Emergency Systems Clear lens with FIRE lettering provides visible notification for fire alarm Both strobes connect on same SLC are separately addressed and independent operation Operation is clear Fire OR amber not both Wiring supervision to each strobe allowing T tapped connections for B circuits to simplify wiring Class A circuits require in out wiring TrueAlert Device Reports at the control panel detailing appliance ID custom label type and candela setting Magnet test diagnostics to assist checkout and testing of appliances wiring Compatibility with ADA requirements refer to important installation in Strobe Details and Mounting Height Reference Compatibility with legacy TrueAlert addressable systems for upgrade replacement Clear lens strobe is UL listed to Standard 1971 ULC listed to Standard Amber lens strobe is UL listed to Standard 1638 due to non white and provides light dispersion patterns of UL Standard 1971 ULC is to Standard S526 indicator and magnet test feature Each appliance LED can be selected to display each polling cycle to appliance supervision In diagnostic mode the magnet test pulses the LED to indicate address AND pulses to indicate the intensity selection brief output of the strobe is also selectable to confirm operation design features Rugged high impact flame retardant thermoplastic housing for flush surface wall mount available with red or white housing Individual strobe housings mount onto a common bracket that does extend into box and easily mounts to standard electrical boxes Wall mount wiring terminal access is from front of housing to assist inspection and testing Mounting options include adapter skirts for surface mounting and box plates 1 Clear Amber Strobe Assembly front side view shown available with red or white housing TrueAlert addressable combination strobes individually addressed and individually controlled with power and control supplied from a Autocall fire alarm control panel IDNAC Signaling Line Circuits SLCs See compatibility list page 4 A single assembly provides an amber lens strobe for non alarm alert notification for use with Emergency Communications and a clear lens strobe for fire alarm notification Application Reference strobes used as part of an Emergency Communications system located to provide the same area coverage as required of clear lens alarm strobes Specific Emergency Communications requirements discussed in detail in document UFC 4 021 01 USA Department of United Facilities Criteria and in NFPA 72 Chapter 24 2010 and editions strobe coverage criteria is further described in the National Fire Code NFPA 72 ANSI A117.1 the appropriate model building BOCA ICBO or SBCCI and the application guidelines of the with Disabilities Act ADA This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7125 2269 0527 and for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact your local Autocall product supplier for the latest Rev 4 1 2020 Emergency Communication Appliances Clear Amber Strobes SLC Operation Advantage two wire circuit V O Appliances with Addressable Strobes on IDNAC provide visible notification using a single two wire circuit that also connection to the individual notification appliance electronic This operation increases circuit supervision integrity by providing that extends beyond the appliance wiring connections current allows efficient IDNAC SLC operation IDNAC SLCs a constant 29 VRMS source voltage is maintained during battery standby allowing strobes to operate at higher with lower current and ensuring a consistent current draw and drop margin under both primary power and secondary battery Efficiencies include wiring distances up to 2 to 3 times farther with conventional notification or support for more appliances per SLC or use of smaller gauge wiring or combinations of these all providing installation and maintenance savings with high that appliances that operate during normal system testing will during worst case alarm conditions Installation and Testing Time separate controls on the same two wire SLC installation time and for both retrofit and new construction can be significantly When Class B wiring is used wiring can be T tapped allowing savings in distance wire conduit size and utilization and installation efficiency Use of the magnet test feature improves efficiency TrueAlert device reports conveniently identify about each connected appliance providing an amber lens strobe with a clear lens strobe the strobe assembly allows a single electrical installation to both types of visible notification Addressable Diagnostics Features can be selected to pulse each appliance LED when it a supervision poll When the controller is selected for diagnostic the appliance magnet test feature provides a response at the appliance being tested Appliance Magnet Test this test mode in response to the magnet test the appliance LED sequentially to conveniently indicate the appliance address Appliance Testing this test mode after the address is indicated by pulsing the appliance the strobe will briefly flash to indicate proper operation Instrument Two TSIT 2nd generation of the Autocall TrueStart Test Instrument adds of IDNAC SLC wiring and TrueAlert and TrueAlert ES appliances its ability to test IDCs NACs and IDNet communications before to the control panel Please contact your local Autocall for additional information Wiring Isolator Model A4905 9929 is available for remote mounting on TrueAlert addressable to isolate short circuited wiring from functioning wiring Refer to sheet AC4905 0001 for additional information Device Reports Device Reports detail type candela rating and location per see sample below amber lens type is AMB 2 Rev 4 1 2020 Details and Mounting Height Reference Emergency Communication Appliances Clear Amber Strobes Reference 2 Details and Mounting Height Reference Selection White 1 Product Selection Addressable Combination Strobe assembly with amber ALERT strobe on top and clear lens FIRE strobe on bottom intensity as 15 30 75 or 110 candela H x 5 W x 3 15 16 D 273 mm x 130 x 100 mm 3 Rev 4 1 2020 Emergency Communication Appliances Clear Amber Strobes White Mount Adapter Skirt use to cover surface mounted electrical 1 Product Selection H x 5 W x 1 D 267 mm x 133 x 44 mm depth with strobe assembly 5 143 Strobe and IDNAC SLC Controller Compatibility Reference 2 TrueAlert Strobe and IDNAC SLC Controller Compatibility Reference Controller with EPS or EPS Power Supply IDNAC Repeater Sheet Output SLC Output SLC VRMS regulated Voltage Reference VRMS 6 VRMS drop Instruction 3 Common Specifications to 1

Related Files