Autocall IDNet Addressable Devices, Model A4090-9007 Signal IAM (Individual Addressable Module)

File Preview
File Preview
Click below to download for free

Text Preview

Datasheet Peripherals Addressable Devices Model A4090 9007 Signal IAM Individual Addressable Module ULC CSFM Listed FM IAMs provide additional selective signaling for Autocall 4010ES 4100ES Series fire alarm control panels Signal output notification appliance circuit NAC wiring is supervised connected to the signal input under IDNet communications NAC output is rated 0.5 A for Special Application or Regulated 24 VDC or for audio operation 12.5 W 25 VRMS 35 W 70.7 and can be wired Class B or Class A see Specifications Signal coding of horn strobe control strobe synchronization or other is provided by the signal input coding at the Signal IAM via addressable communications is not supported features Relay contacts isolate signal inputs from outputs during supervision do not monitor signal presence signal inputs sources will need to monitored separately During supervision signal outputs are isolated from signal inputs by contacts allowing consideration for use with SCIF applications Compartmented Information Facilities details Signal IAM operation is powered and supervised by the IDNet communications loop separate 24 VDC is not required the IAM separate signal power is required for the on board NAC Signal IAM communications use a single physical address however Signal IAM reduces the IDNet loop capacity by two addresses to the extra power required for output NAC supervision construction Mounts in standard 4 in square electrical box Visible LED flashes to indicate communications Optional covers are available to allow LED to be viewed after Screw terminals for wiring connections Listed to Standard 864 NAC Operation applications requiring additional individual NAC supervision and the A4090 9007 Signal IAM provides a 0.5 A remote NAC under panel addressable point control IDNet communications monitor Signal IAM status and then connects the output NAC to the separate input for local alarm notification Signal IAM provides additional NACs to the host control panel it not provide additional power Control Signal IAM also allows the control panel to use IDNet to control audio circuits from a compatible Autocall control panel Only one signal source is used per Signal IAM Signal IAMs would be required for control of DC powered such as strobes phone circuits are not supported 1 Signal IAM Reference Signaling Use Signal IAMs to provide additional local area zones per applicable version of NFPA 72 the National Fire and Signaling Code local codes and system requirements Signaling Use Signal IAMs to connect to higher current rated output is 0.5 A retrofit of Class B NAC wiring where only two wires are available in connections can be made at the Signal IAM maintaining appliance supervision per applicable version of NFPA 72 and local codes IAM operation is programmed at the fire alarm control panel per requirements Requirements Signal IAMS with both IDNet communications and signal NAC input the latest requirements of UL 864 and to NFPA 72 per local code This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7300 2269 0538 7165 2269 0514 and 7300 2269 0567 for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact your local supplier for the latest status Rev 10 03 2021 Addressable Devices Model A4090 9007 Signal IAM Individual Addressable Module 4 Additional Information Control Panel Control Panel Selection 5 Product Selection IAM programming types are hardware type for 4008 device type SIGIAM for other fire alarm control panels For semi flush mounted box For surface mounted box trim plate with viewing window mounting galvanized steel Communications Isolator may be required for connections to Signal IAM refer to data sheet for details End of line resistor for Signal IAM NAC output when Class B 10 k 1 2 W ref 733 894 Protector for up to 200 mA DC or IDNet required where wiring exits and enters building refer to data sheet AC2081 0016 for details Loading Input Choices Output 1 Electrical communications one address two unit loads each Signal IAM the IDNet loop capacity by two refer to the IDNet source for the total address capacity 24 VDC from control panel NAC or NAC VRMS or 70.7 VRMS from compatible listed source Application or Regulated 24 VDC 0.5 A rating for speakers 0.5 A 25 VRMS 12.5 or 70.7 VRMS 35 W with Autocall strobe synchronization compatible with SmartSync 2 wire horn control or with TrueAlert addressable for horn strobe appliance applications 4 wire appliances for horn control select operation as free run Connections Screw terminals for in out wiring 18 to 12 AWG Class B NAC 10 k 1 2 W A4081 9008 0.82 mm2 to 3.31 mm2 2 Wiring Distance Information Reference Reference Wiring ft 762 m maximum distance from panel ft 3048 m maximum total wiring including T Taps on Class B wiring IDNet communications specifications vary depending on the host fire alarm panel refer to specific panel product for details connections from the NAC Riser the Signal IAMs and to the notification are branch circuits on the NAC Riser must be calculated accordingly distances are limited by wire size and the voltage drop from the fire alarm control to the Signal IAM and then to the farthest appliance per branch connection Signal IAM voltage drop is considered for wiring distance calculations 3 Mechanical in x 4 1 8 in x 1 1 4 in D 102 mm x 105 mm x 32 to 120 F 0 to 49 C indoor operation only to 93 RH at 100 F 38 C 4 Additional Information Rating Instructions Basic Audio Hybrid IDNet Isolator Isolator Base 2 Rev 10 03 2021 Addressable Devices Model A4090 9007 Signal IAM Individual Addressable Module Wiring Reference 2 Wiring Reference 2 notes When IDNet SLC isolation is required use A4090 9116 IDNet addressable isolators or A4098 9793 IDNet Isolator sensor bases 4007ES 4010ES 4100ES These panels control 4009 IDNet NAC Extenders by IDNet communications for 4100ES systems audio signals are isolators are used the first and last isolators are recommended to be close nippled in conduit and within 20 ft 6 m of the panel provided by their system audio NACs 3 Rev 10 03 2021 Addressable Devices Model A4090 9007 Signal IAM Individual Addressable Module Information 2021 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without notice listings may be applicable contact your local Autocall product supplier for the latest status Listings and approvals under Tyco Fire Security GmbH and the names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are registered of the National Fire Protection Association NFPA Rev 10 03 2021

Related Files