Autocall IDNet Communicating Devices Addressable Manual Stations

File Preview
File Preview
Click below to download for free

Text Preview

Datasheet Peripherals Communicating Devices Addressable Manual Stations Action Stations Breakglass require the operator to strike front mounted hammer to break the glass and expose the recessed lever The pull lever then operates as a single action station action NO Single action NO Retrofit kit Breakglass Push A2099 9828 Cover kit Action Stations Push Type require that a spring loaded plate marked PUSH be pushed back to access the pull of the single action station reset requires the use of a key to reset the manual station lever deactivate the alarm switch If you use the break rod you must it testing is performed by physical activation of the pull lever You also perform electrical testing by unlocking the station housing to the alarm switch ULC CSFM Listed FM addressable manual fire alarm stations with Power and data supplied by IDNet addressable communications using single wire pair Operation that complies with ADA requirements Visible LED indicator that flashes during communications and is on when the station has been activated The NO GRIP Single Action Station and Retrofit Kit are available with more easily operated pull lever for applications where anticipated may find the standard station lever difficult to activate Pull lever that protrudes when alarmed Break rod supplied use is optional Models are available with single or double action breakglass or push UL listed to Standard 38 NEMA 1 rated See Addressable manual station product selection for information with the following Autocall control panels Model Series 4007ES 4010ES 4100ES fire alarm control panels with IDNet communications construction Electronics module enclosure minimizes dust infiltration Allows mounting in standard electrical boxes Screw terminals for wiring connections resistant reset key lock keyed same as Autocall fire cabinets mounting options Surface or semi flush with standard boxes or matching Autocall boxes Flush mount adapter kit Adapters are available for retrofitting to commonly available existing Autocall addressable manual station combines the familiar Autocall station housing with a compact communication module is easily installed to satisfy demanding applications Its integral addressable module IAM constantly monitors status and changes to the connected control panel through IDNet wiring of the A4099 9004 single action manual station requires a downward pull to activate the alarm switch Completing the action an internal plastic break rod which is visible below the pull lever is optional The use of a break rod can be a deterrent to vandalism interfering with the minimum pull requirements needed for easy The pull lever latches into the alarm position and remains out of the housing to provide a visible indication Action NO GRIP Station A4099 9021 For applications such as Building Code Title 24 which requires Controls and operating shall be operable with one hand and shall not require grasping pinching or twisting of the wrist the model A4099 9021 provides a more easily operated pull lever compared to standard Retrofit of existing stations is available using the A4099 9805 kit This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listing 7150 2269 0515 for allowable and or conditions concerning material presented in this document Additional listings may be applicable contact your local product supplier for the latest status Rev 5 03 2021 Communicating Devices Addressable Manual Stations to 4099 MAPNET II IDNet Addressable Manual Pull Station with LED Installation Instructions 579 1135AC for additional information and communications means connections listed temperature range range color lever color dimensions 1 Specifications communications 1 address for each station switch 8 position terminal for in out wiring for 18 AWG to 14 AWG wire 0.82 mm2 to 2.08 mm2 to 120 0 to 49 intended for indoor operation to 93 RH at 100 38 with white raised lettering and pull lever are Lexan polycarbonate or equal with red raised lettering in H x 3 3 4 in W x 1 in D 127 mm x 95 mm x 25 mm manual station semi flush mounting 1 manual station semi flush mounting 2 Rev 5 03 2021 Communicating Devices Addressable Manual Stations manual stations surface mounting mounting For surface mounting of these addressable manual stations the preferred electrical boxes are shown in Figure 2 mounting reference See Addressable manual station additional mounting information for Wiremold box mounting compatibility 2 shows the 2975 9178 box and the 2975 9022 cast box 2 Series addressable manual station 3 Rev 5 03 2021 mount side view with internal detail 3 shows the 2975 9178 box Communicating Devices Addressable Manual Stations 3 mount side view with internal detail reference to NFPA 72 the National Fire Alarm and Signaling Code and all applicable local codes for complete requirements for manual stations The summarizes the basic requirements Stations shall be located in the normal path of exit and distributed in the protected area such that they are unobstructed and readily accessible Mounting shall be with the operable part not less than 42 in 1.07 m and not more than 48 in 1.22 m above floor level At least one station shall be provided on each floor Additional stations shall be provided to obtain a travel distance not more than 200 ft 61 m the nearest station from any point in the building When manual station coverage appears limited in any way additional stations should be installed 4 Rev 5 03 2021 manual station additional mounting information retrofit and new installations additional compatible mounting boxes and the required adapter plates are shown in Figure 4 Figure 4 shows the surface trim for Wiremold boxes and the 2099 9813 semi flush trim for 2 gang switch boxes Communicating Devices Addressable Manual Stations 4 manual station additional mounting information manual station flush mounting information flush mount adapter kit is available in beige 2099 9820 or black 2099 9819 5 manual station flush mounting information 5 Rev 5 03 2021 Communicating Devices Addressable Manual Stations manual station product selection 2 Addressable manual station product selection red housing with white letters and white pull lever Action English ULC FM Action Bilingual English and lever DOWN ALARM PULL FIRE FM Action Portuguese see note see see note Single Action French see see note Single Action Spanish see note Double Action Breakglass English Action Breakglass see Portuguese see note Double Action Breakglass see note Double Action Push operation Action Push operation see see note Double Action Push operation Action NO GRIP operation see note Spanish NEMA 1 rated when used with 2975 9178 back box FEU ALARME FUEGO ALARM ALARME FUEGO DOWN ULC FM ALARM PULL DOWN ULC FM ALARME PUXE FUEGO JALE ALARM DOWN ULC FM FM FM FM 3 Accessories aluminum surface mount box red mount steel box red trim plate for double gang switch box red mount adapter kit black mount adapter kit beige Kit for field conversion of a single action station to a NO GRIP station refer to the NO GRIP Actuator 4099 9805 Installation 579 1007AC for details breakglass

Related Files