Cornell Communications 4200 Rescue Assistance Overview
File Preview
Click below to download for free
Click below to download for free
File Data
Name | cornell-communications-4200-rescue-assistance-overview-3152064789.pdf |
---|---|
Type | |
Size | 1.07 MB |
Downloads |
Text Preview
Area of Rescue Refuge Assistance 4200 Series Assistance 4200 Vandal Resistant Station Mushroom Switch 4 zone Annunciator shown to 44 Zones Available Communication Need The Americans with Disabilities Act ADA now being enforced requires a Rescue Assistance in all newly constructed multi story commercial buildings and public accommodations to provide a means to request assistance in emergencies The ADA also applies to significant renovations of existing multi story facilities Reassuring Solution The 4200 Series Audio Rescue Assistance System is a time proven Rescue Assistance System has received wide industry acceptance The 4200 includes voice communication which is initiated by simply depressing call station button transmitting the signal to a central annunciator panel and optional access to a public telephone line A pulse tone and a flashing light signals the caller that the alarm has been received The control station can then talk to caller The caller need not take any other action to communicate with the control station an important feature when a is under stress in an emergency situation Surface Finish Our new self cleaning ceramic polymer coating preserves and protects the annunciator finish Sizes Available Now available in standard sizes to 44 zones Call factory for larger applications Dependable The control station operator on receiving a call station signal activates a zone switch that both a flashing red LED and a green LED By depressing and releasing the button voice is established for as long as required Upon completion the appropriate zone button is depressed again the flashing red light continues If more than one zone is signaling the control station accepts the calls in the same When the emergency is resolved the control station operator pushes a reset switch that restores the entire system stand by status In the event of a wiring fault each annunciator zone is equipped with a yellow LED that will illuminate and alarm will sound identifying the area requiring service Resistant CORNELL now offers as standard Vandal Resistant call stations with optional outdoor application call This design offers heavy duty switches and speakers along with heavy gauge stainless steel plates and Phillips The outdoor station is coated for temperature and water protection Tamper proof screws are available for purchase with the tool to install them if required CORNELL offers a complete line of Rescue Assistance Signage This includes powered signs including battery and our RADIANCE photoluminescent room identification signs as well as 4201B VM Vandal Resistant Call with Mushroom Switch direction and location signs These signs meet ADA specifications for use with Areas of Assistance Box Box Size Panels or A 4220 or 20 or A 4236 or A 4244 or 36 or 44 Size x 10 W x 14 W x 18 W x 14 W x 18 W x 18 W x 22 W x 26 W x 9 W x 3.5 D x 13 W x 3.5 D x 17 W x 3.5 D x 13 W x 3.5 D x 17 W x 3.5 D x 17 W x 3.5 D x 21 W x 3.5 D x 25 W x 3.5 D Note For 4200 systems larger than 24 zones 2 power supplies are required 1 set at 24 Volts 1 set at 12 Volts Switch Station Switch Switch Gang Plate x 4.5 W 2 Outlet 2 Gang Box Supply Backup Power Supply 24VDC 3AMP standby power with Cornell supplied x 12 W x 4.5 D Access Kits TAK 4202 input auto dialer and digital announcer input auto dialer and digital announcer x 3.6 x 1.75 x 6.3 x 1.8 Cable manufactured cable for the Cornell Series ARA System Rolls CORNELL Annunciator Panel shall include alternate action switch with two internal LED for each zone An audible alarm on the Panel will emit a minimum sound level 90db at 30cm A yellow LED light for each zone illuminate and the alarm will emit a repeating if any of the supervised lines are faulted panel shall be constructed of anodized with permanently silk screened zone on the panel as well as a designation The CORNELL Call Station 4201B V 4201B or 4202 shall consist of one momentary switch LED and one audible alarm device with a level minimum of 70db at 30cm The station be wall mounted on a stainless steel plate and vandal resistant 4200 Series can be wired to have a remote monitor This Panel will be for monitoring only no remote is available on this system 4200 Series Mushroom Switch call station have a contact that can be used to activate external such as a camera strobe or tone device Requirements CB 4200 Cable is recommended Four plus one shielded pair are required between Call Station and the Annunciator Panel not to exceed feet Power wire shall be 18 gauge minimum Two are required between the Power Supply and Annunciator Panel not to exceed 500 feet The TAK TAK 4208 requires a 120V AC outlet and an telephone line PANEL STATION Acknowledged Activated Red LED Steady Green LED One Time Tone Mode Sent On Off Fault Light Tone Light Tone LED Intermittent Tone LED Tone One Time to Talk Release to Listen Free Communication Red LED Access Zone Switch Button LED at Zone Access Zone Switch will not light