Cornell Communications 4200 Rescue Assistance Product Specification
File Preview
Click below to download for free
Click below to download for free
File Data
Name | cornell-communications-4200-rescue-assistance-product-specification-8796421305.pdf |
---|---|
Type | |
Size | 616.96 KB |
Downloads |
Text Preview
Rescue Assistance Signal System Audio Visual 4200 Audio Visual Series Specs document specifies rescue assistance equipment for emergency signaling This provides voice communication which is initiated by depressing the call station transmitting the signal to a central annunciator panel as manufactured by Communications Inc Milwaukee WI 1 General SUMMARY Includes Furnish install and wire all equipment associated with installation of an Audio Visual Rescue Assistance Signal System to with ADA requirements This work shall include a main panel remote call stations power supply outlet boxes cables wiring as shown on the drawings and as specified herein SUBMITTALS Data sheets on all equipment being provided as well cable types Internal control cabinet drawings showing block diagram connections shall be provided Wiring diagrams typical field wiring connections as well as single line floor plan equipment locations as well as cable routings and quantities Data Submit product data including manufacturer Spec product sheet for specified products Drawings Submit shop drawings showing layout profiles and components including anchorage and accessories Include cabling wiring diagrams station installation details and equipment details Assurance Submittals Submit the following Reports Certified test reports showing compliance with performance characteristics Instructions Manufacturer installation Field Reports Manufacturer field reports herein Assistance Signal System Audio Visual Submittals Submit the following and Maintenance Data Operation and maintenance data installed products in accordance with Division 1 Closeout Maintenance Data and Operation Data Section methods for maintaining installed products and precautions cleaning materials and methods detrimental to finishes and Include troubleshooting guide wiring terminal and equipment parts list Warranty documents specified herein Closeout one year maintenance contract offering continued factory service of this system shall be provided as part of this Built drawings that include changes to wiring wiring junction box labeling and other pertinent information be supplied upon completion of the project contractor shall furnish manufacturer manuals of the system including individual specifications sheets inter panel and intra panel wiring diagrams information necessary for the proper maintenance and of the system must be included four copies built drawings that include changes to wiring wiring junction box labeling and other pertinent shall be supplied upon completion of the project a minimum of two 2 hours of in service training with the sessions shall be broken into segments that will the training of the system users in operating equipment manuals and user guides shall be provided at time of training WARRANTY Warranty Refer to Conditions of the Contract for project provisions Manufacturer Warranty Submit for Owner acceptance standard warranty document executed by authorized official Manufacturer warranty is in addition to and not a of other rights Owner may have under Contract Documents Assistance Signal System Audio Visual Period Specify term years commencing on the Date of Completion materials and installation shall be guaranteed to be free of in material and workmanship for one year after final of installation and tests INSTALLATION STANDARDS system shall be installed in accordance with the 1993 NEC and ADA completed system shall be in compliance with state and local codes wiring shall test free from grounds and shorts SYSTEM OPERATIONS install and place into operation a Rescue Assistance System for building as indicated on the drawings and as specified herein common annunciator shall be provided at the main building entrance shown on the drawings to indicate light and tone signals from remote call stations the call station switch is activated a red LED button and a one shot tone sounds the alarm signal is acknowledged the remote call station is with a flashing light and tone communication with the remote call can then be initiated the annunciator access to a public telephone system shall be provided specified 2 Products Rescue Assistance System Audio Visual RESCUE ASSISTANCE VISUAL EQUIPMENT A Manufacturer Cornell Communications Inc 7915 N 81st St Milwaukee WI 53223 3830 800 558 8957 414 351 4660 Fax 414 351 4657 PRODUCT SUBSTITUTIONS No substitutions permitted Assistance Signal System Audio Visual CORNELL 4200 RESCUE ASSISTANCE AUDIO VISUAL SYSTEM AND system shall consist of multiple remote call stations which share a common annunciator panel and optional access to a telephone system for external alarm notification annunciator panel shall be a CORNELL Model A42XX with for XX zones surface mounted at the Main Fire Entrance to the building location with the Local Fire Marshal and the alternate action switch with internal LED indicator shall be for each zone yellow LED light on the zone switch shall illuminate and alarm shall emit a repeating sound if the supervised is faulted audible alarm shall be mounted on the annunciator panel will emit a minimum sound level of 90 db at 30 cm when a station calls the zone switch will answer a zone and open intercom line to the zone front panel shall have silk screened zone designations and directions as well as zone designation strips power supply shall be a 120 volt emergency battery backup model B 5243A or P 512243A optional TAK 4200 telephone access kit will place a call to a location via a dedicated public telephone line to notify of the alarm remote call station shall be CORNELL Model 4201B V or vandal resistant with one momentary switch with LED loudspeaker station shall have hands free voice communication with the The station shall have silk screened operating instructions station shall be flush wall mounted on a 2 gang stainless steel with a 48 maximum mounting height for forward reach and 54 maximum for side reach Assistance Signal System Audio Visual Call Stations SOURCE QUALITY Quality Obtain rescue assistance equipment and system from a manufacturer 3 Execution MANUFACTURER INSTRUCTIONS Comply with manufacturer product data including technical bulletins product catalog installation instructions and carton instructions for installation Verification of Conditions Verify substrate conditions which have previously installed under other sections are acceptable for product in accordance with manufacturer instructions EXAMINAITON INSTALLATION Requirements from the annunciator to the call station shall be CORNELL custom cable Wiring from the annunciator to the power supply shall be 18 2 conductor cable types with the Rescue Assistance System optional telephone access kit requires a 120V AC outlet and external telephone line Assistance Signal System Audio Visual Installation system shall be installed in strict accordance with recommendations shall be installed in raceways throughout the building if required shall be 1 2 minimum FIELD QUALITY REQUIREMENTS Tests Post Installation Testing Checkout final connections to the shall be made by a factory techn